Orthogonal Chirp Coded Excitation in a Capacitive Micro-machined Ultrasonic Transducer Array for Ultrasound Imaging: A Feasibility Study

被引:0
作者
Kim, Bae-Hyung [1 ]
Lee, Seungheun [2 ]
Kim, Kang-Sik [3 ]
机构
[1] Samsung Elect Co Ltd, Samsung Adv Inst Technol, Suwon 16678, South Korea
[2] Dong Eui Univ, Dept Mech Automot & Robot Engn, Busan 47340, South Korea
[3] Samsung Elect Co Ltd, Hlth & Med Equipment Dept, Suwon 16678, South Korea
关键词
CMUT; coded excitation; orthogonal chirps; simultaneous transmission multiple-zone focusing; frequency division multiple access; MEDICAL ULTRASOUND; PULSE-COMPRESSION; FOCUSING METHOD; GOLAY CODES; SYSTEM; SIGNALS; DESIGN; MOTION;
D O I
10.3390/s19040883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It has been reported that the frequency bandwidth of capacitive micro-machined ultrasonic transducers (CMUTs) is relatively broader than that of other ceramic-based conventional ultrasonic transducers. In this paper, a feasibility study for orthogonal chirp coded excitation to efficiently make use of the wide bandwidth characteristic of CMUT array is presented. The experimental result shows that the two orthogonal chirps mixed and simultaneously fired in CMUT array can be perfectly separated in decoding process of the received echo signal without sacrificing the frequency bandwidth each chirp. The experimental study also shows that frequency band-divided orthogonal chirps are successfully compressed to two short pulses having the -6 dB axial beam-width of 0.26- and 0.31-micro second for high frequency and low frequency chirp, respectively. B-mode image simulations are performed using Field II to estimate the improvement of image quality assuming that the orthogonal chirps designed for the experiments are used for simultaneous transmission multiple-zone focusing (STMF) technique. The simulation results show that the STMF technique used in CMUT array can improve the lateral resolution up to 77.1% and the contrast resolution up to 74.7%, respectively. It is shown that the penetration depth also increases by more than 3 cm.
引用
收藏
页数:18
相关论文
共 53 条
[1]  
[Anonymous], 2014, DIAGNOSTIC ULTRASOUN
[2]  
[Anonymous], 1996, Opt. Eng
[3]  
Bae MH, 2002, ULTRASON, P1705
[4]   An Experimental Study on Coded Excitation in CMUT Arrays to Utilize Simultaneous Transmission Multiple-zone Focusing Method with Frequency Divided Sub-band Chirps [J].
Kim, Bae-Hyung ;
Lee, Seungheun ;
Kim, Youngil ;
Cho, Kyungil ;
Jeon, Taeho ;
Kim, Kyuhong ;
Song, Jongkeun .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :1420-1423
[5]   Pulse Compression in Nondestructive Testing Applications: Reduction of Near Sidelobes Exploiting Reactance Transformation [J].
Burrascano, Pietro ;
Laureti, Stefano ;
Senni, Luca ;
Ricci, Marco .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2019, 66 (05) :1886-1896
[6]   A New Synthetic Aperture Focusing Method to Suppress the Diffraction of Ultrasound [J].
Chang, Jin Ho ;
Song, Tai-Kyong .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (02) :327-337
[7]   Coded excitation for diagnostic ultrasound: A system developer's perspective [J].
Chiao, RY ;
Hao, XH .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) :160-170
[8]  
Chiao RY, 2000, ULTRASON, P1677, DOI 10.1109/ULTSYM.2000.921644
[9]   Packaging and design of reconfigurable arrays for volumetric imaging [J].
Fisher, R. ;
Wodnicki, R. ;
Cogan, S. ;
Thomas, R. ;
Mills, D. ;
Woychik, C. ;
Lewandowski, R. ;
Thomenius, K. .
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, :407-410
[10]  
GOLAY MJE, 1961, IRE T INFORM THEOR, V7, P82, DOI 10.1109/TIT.1961.1057620