Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner

被引:161
|
作者
Visser, Eric P. [1 ]
Disselhorst, Jonathan A. [1 ]
Brom, Maarten [1 ]
Laverman, Peter [1 ]
Gotthardt, Martin [1 ]
Oyen, Wim J. G. [1 ]
Boerman, Otto C. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Nucl Med, NL-6500 HB Nijmegen, Netherlands
关键词
positron emission tomography; small-animal; spatial resolution; sensitivity; image reconstruction; PERFORMANCE EVALUATION;
D O I
10.2967/jnumed.108.055152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Inveon small-animal PET scanner is characterized by a large, 127-mm axial length and a 161-mm crystal ring diameter. The associated high sensitivity is obtained by using all lines of response (LORs) up to the maximum ring difference (MRD) of 79, for which the most oblique LORs form acceptance angles of 38.3 degrees with transaxial planes. The result is 2 phenomena that are normally not encountered in PET scanners: a parallax or depth-of-interaction effect in the axial direction and the breakdown of Fourier rebinning (FORE). Both effects cause a deterioration of axial spatial resolution. Limiting the MRD to smaller values reduces this axial blurring at the cost of sensitivity. Alternatively, 3-dimensional (3D) reconstruction techniques can be used in which the rebinning step is absent. The aim of this study was to experimentally determine the spatial resolution and sensitivity of the Inveon for its whole field of view (FOV). Methods: Spatial resolution and sensitivity were measured using filtered backprojection (FBP) with FORE, FBP with LOR angle-weighted adapted FORE (AFORE), and 3D ordered-subset expectation maximization followed by maximum a posteriori reconstruction (OSEM3D/MAP). Results: Tangential and radial full width at half maximum (FWHM) showed almost no dependence on the MRD using FORE and FBP. Tangential FWHMs were 1.5 mm in the center of the FOV (CFOV) and 1.8 mm at the edge of the FOV (EFOV). Radial FWHMs were 1.5 and 3.0 mm in the CFOV and EFOV, respectively. In contrast, axial FWHMs increased with the MRD and ranged between 1.1 and 2.0 mm in the CFOV and between 1.5 and 2.7 mm in the EFOV for a MRD between 1 and 79. AFORE improved the axial resolution for a large part of the FOV, but image noise increased. OSEM3D/MAP yielded uniform spatial resolution in all directions, with an average FWHM of 1.65 +/- 0.06 mm. Sensitivity in the CFOV for the default energy and coincidence time window was 0.068; peak sensitivity was 0.111. Conclusion: The Inveon showed high spatial resolution and high sensitivity, both of which can be maintained using OSEM3D/MAP reconstruction instead of rebinning and 2D algorithms.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [31] The 100μPET project: A small-animal PET scanner for ultra-high resolution molecular imaging with monolithic silicon pixel detectors
    Cadoux, Franck
    Cardella, Roberto
    Iacobucci, Giuseppe
    Iodice, Luca
    Ferrere, Didier
    Gonzalez-Sevilla, Sergio
    Kugathasan, Thanushan
    Martinelli, Fulvio
    Paolozzi, Lorenzo
    Picardi, Antonio
    Saidi, Jihad
    Vicente, Mateus
    Zambito, Stefano
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [32] Image-Quality Assessment for Several Positron Emitters Using the NEMA NU 4-2008 Standards in the Siemens Inveon Small-Animal PET Scanner
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelius H.
    Boerman, Otto C.
    Oyen, Wim J. G.
    Gotthardt, Martin
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 610 - 617
  • [33] An evaluation of exact and approximate 3-D reconstruction algorithms for a high-resolution, small-animal PET scanner
    Farquhar, TH
    Chatziioannou, A
    Cherry, SR
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) : 1073 - 1080
  • [34] A Prototype Ultra-High-Resolution Small-Animal PET System
    Liu, Jiguo
    Liu, Qiong
    Chen, Jyh-Cheng
    Wang, Deguang
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [35] Image quality as a function of reconstruction algorithms and their parameter settings for the Siemens Inveon small-animal PET scanner evaluated using the NEMA NU4 2008 standards
    Visser, E. P.
    Disselhorst, J. A.
    van Lier, M. G. J. T.
    Laverman, P.
    Gotthardt, M.
    Oyen, W. J. G.
    Boerman, O. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S171 - S171
  • [36] Evaluation of a newly developed small-animal PET scanner in experimental myocardial infarction.
    Morguet, AJ
    Chatziioannou, AF
    Cherry, SR
    Phelps, ME
    Schelbert, HR
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 9P - 9P
  • [37] Design and Development of a Small-Animal PET Scanner Based on Pixelated Crystals and Silicon Photomultipliers
    My, M.
    Zeraatkar, N.
    Sajedi, S.
    Taheri, M.
    Kaviani, S.
    Sarkar, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S430 - S431
  • [38] Absolute Quantification for Small-Animal PET
    Keereman, Vincent
    Van Holen, Roel
    Vanhove, Christian
    Mollet, Pieter
    Vandenberghe, Stefaan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3715 - 3719
  • [39] Innovations in Small-Animal PET Instrumentation
    Lehnert, Adrienne L.
    Miyaoka, Robert S.
    PET CLINICS, 2024, 19 (01) : 59 - 67
  • [40] Development of a small-animal PET system
    Ziegler, SI
    PROCEEDINGS OF THE IEEE, 2005, 93 (04) : 763 - 770