Mathematical model for the calculation of oxygen concentrations in a closed circuit oxygen rebreathing apparatus

被引:0
|
作者
Neubauer, B
Zander, R
Tetzlaff, K
机构
[1] FED GERMAN NAVY WEAPONS DIVER BATTAL,ECKERNFORDE,GERMANY
[2] UNIV MAINZ,DEPT PHYSIOL & PATHOPHYSIOL,D-6500 MAINZ,GERMANY
[3] USN,INST MED,DEPT DIVING & HYPERBAR MED,KRONSHAGEN,GERMANY
来源
AVIATION SPACE AND ENVIRONMENTAL MEDICINE | 1997年 / 68卷 / 08期
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Closed circuit oxygen rebreathing diving apparatus are used by armed forces in special tasks because of their advantages of long endurance, low noise and minimal gas escape. There is little knowledge about the administered oxygen concentrations in these systems. Closed circuit oxygen rebreathing apparatus are also used as a first aid device for the treatment of severe disorders. Because of similar constructive components, these rebreathing apparatus are comparable to the Drager LAR V model. Hypothesis: This study was conducted to measure the oxygen concentrations in the LAR V and estimate the correlation between oxygen concentration and pre-breathing purges. Method: Subjects were 12 males who performed the pre-breathing procedure. The oxygen concentrations in the breathing loop were measured after each purge. Results: The oxygen concentrations depended on the volume of the apparatus' dead space, the total capacity of the divers breathing system respective to the volume of the breathing purges and the number of pre-breathing purges. The maximum oxygen concentration was reached after eight purges (O-2 = 85%). An equation to estimate the oxygen concentration inside the LAR V and first aid rebreather was derived. Conclusions: The results indicated that the present purging procedure (three purges) before diving is normally not sufficient to remove the nitrogen totally from the deadspace of the LAR V, the divers airways and lungs. Only a small modification (six purges) is necessary to improve the safety of the diver in case of a diving apparatus malfunction during the mission profile.
引用
收藏
页码:722 / 725
页数:4
相关论文
共 50 条
  • [41] Mathematical model of the oxygen regime of Cartagena Bay
    Tuchkovenko, YS
    Lonin, SA
    ECOLOGICAL MODELLING, 2003, 165 (01) : 91 - 106
  • [42] Mathematical model for ion refractivity of oxygen in slags
    Susa, M
    Nagata, K
    IRONMAKING & STEELMAKING, 1997, 24 (03) : 239 - 242
  • [43] Mathematical Model of Oxygen Transport in Tuberculosis Granulomas
    Datta, Meenal
    Via, Laura
    Chen, Wei
    Baish, James
    Xu, Lei
    Barry, Clfton
    Jain, Rakesh
    CANCER RESEARCH, 2017, 77
  • [44] Mathematical model for nitrogen control in oxygen steelmaking
    D. A. Goldstein
    R. J. Fruehan
    Metallurgical and Materials Transactions B, 1999, 30 : 945 - 956
  • [45] A MATHEMATICAL MODEL OF PHOTOMETRIC OXYGEN CONSUMPTION IN PHOTOPOLYMER
    SMITH, DK
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1968, 12 (05): : 263 - &
  • [46] Oxygen storage module with physisorption technology for closed-circuit respirators
    Swanger, A. M.
    Fesmire, J. E.
    Fernando, R.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [47] TOTALLY CLOSED-CIRCUIT NITROUS OXIDE-OXYGEN ANESTHESIA
    BARTON, F
    NUNN, JF
    BRITISH JOURNAL OF ANAESTHESIA, 1975, 47 (03) : 350 - 357
  • [48] CLOSED-CIRCUIT SYSTEM FOR EXPERIMENTAL STUDIES OF HYPERBARIC OXYGEN THERAPY
    HOPKINSON, WI
    JOURNAL OF PHYSIOLOGY-LONDON, 1964, 170 (02): : P38 - &
  • [49] Oxygen consumption:: Validation of the closed-circuit PhysioFlex® anaesthesia machine
    Hofland, J
    Tenbrinck, R
    ANESTHESIA AND ANALGESIA, 2004, 99 (01): : 306 - 306
  • [50] THERMODYNAMIC CALCULATION OF CONCENTRATIONS OF SEPARATE COMPONENTS IN THE PHOSPHORUS-OXYGEN SYSTEM
    AZIEV, RG
    TENENBAUM, MM
    ZHURNAL VSESOYUZNOGO KHIMICHESKOGO OBSHCHESTVA IMENI D I MENDELEEVA, 1981, 26 (01): : 93 - 94