Mathematical model for the calculation of oxygen concentrations in a closed circuit oxygen rebreathing apparatus

被引:0
|
作者
Neubauer, B
Zander, R
Tetzlaff, K
机构
[1] FED GERMAN NAVY WEAPONS DIVER BATTAL,ECKERNFORDE,GERMANY
[2] UNIV MAINZ,DEPT PHYSIOL & PATHOPHYSIOL,D-6500 MAINZ,GERMANY
[3] USN,INST MED,DEPT DIVING & HYPERBAR MED,KRONSHAGEN,GERMANY
来源
AVIATION SPACE AND ENVIRONMENTAL MEDICINE | 1997年 / 68卷 / 08期
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Closed circuit oxygen rebreathing diving apparatus are used by armed forces in special tasks because of their advantages of long endurance, low noise and minimal gas escape. There is little knowledge about the administered oxygen concentrations in these systems. Closed circuit oxygen rebreathing apparatus are also used as a first aid device for the treatment of severe disorders. Because of similar constructive components, these rebreathing apparatus are comparable to the Drager LAR V model. Hypothesis: This study was conducted to measure the oxygen concentrations in the LAR V and estimate the correlation between oxygen concentration and pre-breathing purges. Method: Subjects were 12 males who performed the pre-breathing procedure. The oxygen concentrations in the breathing loop were measured after each purge. Results: The oxygen concentrations depended on the volume of the apparatus' dead space, the total capacity of the divers breathing system respective to the volume of the breathing purges and the number of pre-breathing purges. The maximum oxygen concentration was reached after eight purges (O-2 = 85%). An equation to estimate the oxygen concentration inside the LAR V and first aid rebreather was derived. Conclusions: The results indicated that the present purging procedure (three purges) before diving is normally not sufficient to remove the nitrogen totally from the deadspace of the LAR V, the divers airways and lungs. Only a small modification (six purges) is necessary to improve the safety of the diver in case of a diving apparatus malfunction during the mission profile.
引用
收藏
页码:722 / 725
页数:4
相关论文
共 50 条
  • [21] Mathematical model for oxygen diffusion in the retina
    Seth, Deepti
    Mishra, K. P.
    Ghai, Roma
    Mishra, Rashmi
    Kumar, Anil
    MATERIALS TODAY-PROCEEDINGS, 2022, 57 : 2372 - 2375
  • [22] A MATHEMATICAL MODEL OF PLACENTAL OXYGEN TRANSFER
    KIRSCHBAUM, TH
    SHAPIRO, NZ
    JOURNAL OF THEORETICAL BIOLOGY, 1969, 25 (03) : 380 - +
  • [24] Accuracy of feedback-controlled oxygen delivery into a closed anaesthesia circuit for measurement of oxygen consumption
    Schindler, AW
    Scheeren, TWL
    Picker, O
    Doehn, M
    Tarnow, J
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (03) : 281 - 290
  • [25] Determination of new increments for the calculation of limiting oxygen concentrations
    Fuss, O
    Molnarne, M
    Schönbucher, A
    Schröder, V
    CHEMIE INGENIEUR TECHNIK, 2002, 74 (06) : 827 - 832
  • [26] Influence of the reference gas of a paramagnetic oxygen analyzer on nitrogen concentrations during closed-circuit anesthesia.
    Hendrickx, JFA
    Van Zundert, AAJ
    De Wolf, AM
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [27] THE MEASUREMENT OF OXYGEN CONSUMPTION IN SMALL ANIMALS BY A CLOSED CIRCUIT METHOD
    MACLAGAN, NF
    SHEAHAN, MM
    JOURNAL OF ENDOCRINOLOGY, 1950, 6 (04) : 456 - &
  • [28] Mathematical model of oxygen minimum zones in the vertical distribution of oxygen in the ocean
    Alhassan, Yazeed
    Siekmann, Ivo
    Petrovskii, Sergei
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [29] Alga-based mathematical model of a life support system closed in oxygen and carbon dioxide
    Semyonov, D. A.
    Degermendzhi, A. G.
    VAVILOVSKII ZHURNAL GENETIKI I SELEKTSII, 2023, 27 (07): : 878 - 883
  • [30] A MATHEMATICAL-MODEL FOR ELECTRODIALYSIS EQUIPMENT WITH CLOSED BRINE CIRCUIT
    KRASNOVA, TA
    KUTERGINA, LV
    SEMENOV, AG
    SOVIET ELECTROCHEMISTRY, 1986, 22 (01): : 111 - 114