Incremental value of multiplex real-time PCR for the early diagnosis of sepsis in the emergency department

被引:12
|
作者
Schaub, Nora [1 ]
Boldanova, Tujana [1 ]
Noveanu, Markus [1 ]
Arenja, Nisha [1 ]
Hermann, Heinz [2 ]
Twerenbold, Raphael [1 ]
Frei, Reno [3 ]
Bingisser, Roland [4 ]
Trampuz, Andrej [2 ,5 ]
Mueller, Christian [1 ]
机构
[1] Univ Basel Hosp, Dept Internal Med, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Infect Dis Res Lab, Dept Biomed, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Microbiol Lab, CH-4031 Basel, Switzerland
[4] Univ Basel Hosp, Emergency Dept, CH-4031 Basel, Switzerland
[5] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, Germany
基金
瑞士国家科学基金会;
关键词
multiplex real-time PCR; sepsis; emergency department; POLYMERASE-CHAIN-REACTION; RAPID DETECTION; BLOOD CULTURE; UNITED-STATES; EPIDEMIOLOGY; BACTEREMIA; INFECTION; BACTERIAL; THERAPY; ASSAY;
D O I
10.4414/smw.2014.13911
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Delayed recognition of sepsis and inappropriate initial antibiotic therapy are associated with increased mortality and morbidity. The early detection of the causative organism in sepsis is an unmet clinical need. A novel multiplex real-time polymerase chain reaction (MRT-PCR) (SeptiFast (R)) technique may provide the microbiological diagnosis within six hours. METHODS: We assessed the diagnostic accuracy of blood cultures and MRT-PCR in a comparative diagnostic cohort study in 110 consecutive adult patients presenting to the emergency department (ED) with suspected sepsis. RESULTS: We collected 205 corresponding PCR samples and blood culture (BC) pairs from the 110 patients. There was moderate to high concordance between PCR and BC with 181 (88%) matching and 24 (12%) mismatching samples. The diagnostic accuracy of MRT-PCR in detecting sepsis and its causative organism was comparable to that of BCs. The additional use of MRT-PCR significantly reduced the time to microbiological diagnosis as compared to the use of conventional microbiological methods alone (mean time gained 3.9 hours, range 0-66 hours, p < 0.001). CONCLUSION: Diagnostic accuracy of BCs and MRT-PCR in the early diagnosis of sepsis and its causative organism in the ED are comparable. However, MRT-PCR reduces the time to microbiological diagnosis. Whether a more rapid detection of the organism by MRT-PCR could improve the outcome of patients has to be assessed in large prospective randomised trials.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Real-Time Multiplex PCR Analysis in Infectious Uveitis
    Minkus, Caroline L.
    Bispo, Paulo J. M.
    Papaliodis, George N.
    Sobrin, Lucia
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (04) : 252 - 255
  • [42] A novel biomarker panel with a Multimarker Index value for the diagnosis of sepsis in the Emergency Department
    E Rivers
    N Shapiro
    JE Hollander
    R Birkhahn
    R Otero
    T Osborn
    D Milzman
    E Moretti
    B Nguyen
    S Trzeciak
    K Gunnerson
    Critical Care, 10 (Suppl 1):
  • [43] Multiplex Real-Time PCR Assay for Six Major Carbapenemase Genes
    Yoshioka, Nori
    Hagiya, Hideharu
    Deguchi, Matsuo
    Hamaguchi, Shigeto
    Kagita, Masanori
    Nishi, Isao
    Akeda, Yukihiro
    Tomono, Kazunori
    PATHOGENS, 2021, 10 (03): : 1 - 6
  • [44] A multiplex magnetic capture hybridisation and multiplex Real-Time PCR protocol for pathogen detection in seafood
    Amagliani, G.
    Omiccioli, E.
    Brandi, G.
    Bruce, I. J.
    Magnani, M.
    FOOD MICROBIOLOGY, 2010, 27 (05) : 580 - 585
  • [45] The potential utility of real-time PCR of the 16S-rRNA gene in the diagnosis of neonatal sepsis
    Istanbullu, Kenan
    Koksal, Nilgun
    Cetinkaya, Merih
    Ozkan, Hilal
    Yakut, Tahsin
    Karkucak, Mutlu
    Dogan, Haldun
    TURKISH JOURNAL OF PEDIATRICS, 2019, 61 (04) : 493 - 499
  • [46] Usefulness of Multiplex Real-Time PCR for Simultaneous Pathogen Detection and Resistance Profiling of Staphylococcal Bacteremia
    Chung, Yousun
    Kim, Taek Soo
    Min, Young Gi
    Hong, Yun Ji
    Park, Jeong Su
    Hwang, Sang Mee
    Song, Kyoung-Ho
    Kim, Eu Suk
    Park, Kyoung Un
    Kim, Hong Bin
    Song, Junghan
    Kim, Eui-Chong
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [47] The evolution of real-time PCR machines to real-time PCR chips
    Lee, Dasheng
    Chen, Pei-Jer
    Lee, Gwo-Bin
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) : 1820 - 1824
  • [48] Preliminary clinical study using a multiplex real-time PCR test for the detection of bacterial and fungal DNA directly in blood
    Wallet, F.
    Nseir, S.
    Baumann, L.
    Herwegh, S.
    Sendid, B.
    Boulo, M.
    Roussel-Delvallez, M.
    Durocher, A. V.
    Courcol, R. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (06) : 774 - 779
  • [49] Diagnosis of sepsis and empirical treatment in the emergency department
    Fuchs, A.
    Pletz, M. W.
    Kaasch, A. J.
    NOTFALL & RETTUNGSMEDIZIN, 2019, 22 (03): : 198 - 204
  • [50] Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
    Lee, Ping Chin
    Chong, Eric Tzyy Jiann
    Anderios, Fread
    Lim, Yvonne A. L.
    Chew, Ching Hoong
    Chua, Kek Heng
    MALARIA JOURNAL, 2015, 14