Incremental value of multiplex real-time PCR for the early diagnosis of sepsis in the emergency department

被引:12
|
作者
Schaub, Nora [1 ]
Boldanova, Tujana [1 ]
Noveanu, Markus [1 ]
Arenja, Nisha [1 ]
Hermann, Heinz [2 ]
Twerenbold, Raphael [1 ]
Frei, Reno [3 ]
Bingisser, Roland [4 ]
Trampuz, Andrej [2 ,5 ]
Mueller, Christian [1 ]
机构
[1] Univ Basel Hosp, Dept Internal Med, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Infect Dis Res Lab, Dept Biomed, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Microbiol Lab, CH-4031 Basel, Switzerland
[4] Univ Basel Hosp, Emergency Dept, CH-4031 Basel, Switzerland
[5] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, Germany
基金
瑞士国家科学基金会;
关键词
multiplex real-time PCR; sepsis; emergency department; POLYMERASE-CHAIN-REACTION; RAPID DETECTION; BLOOD CULTURE; UNITED-STATES; EPIDEMIOLOGY; BACTEREMIA; INFECTION; BACTERIAL; THERAPY; ASSAY;
D O I
10.4414/smw.2014.13911
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Delayed recognition of sepsis and inappropriate initial antibiotic therapy are associated with increased mortality and morbidity. The early detection of the causative organism in sepsis is an unmet clinical need. A novel multiplex real-time polymerase chain reaction (MRT-PCR) (SeptiFast (R)) technique may provide the microbiological diagnosis within six hours. METHODS: We assessed the diagnostic accuracy of blood cultures and MRT-PCR in a comparative diagnostic cohort study in 110 consecutive adult patients presenting to the emergency department (ED) with suspected sepsis. RESULTS: We collected 205 corresponding PCR samples and blood culture (BC) pairs from the 110 patients. There was moderate to high concordance between PCR and BC with 181 (88%) matching and 24 (12%) mismatching samples. The diagnostic accuracy of MRT-PCR in detecting sepsis and its causative organism was comparable to that of BCs. The additional use of MRT-PCR significantly reduced the time to microbiological diagnosis as compared to the use of conventional microbiological methods alone (mean time gained 3.9 hours, range 0-66 hours, p < 0.001). CONCLUSION: Diagnostic accuracy of BCs and MRT-PCR in the early diagnosis of sepsis and its causative organism in the ED are comparable. However, MRT-PCR reduces the time to microbiological diagnosis. Whether a more rapid detection of the organism by MRT-PCR could improve the outcome of patients has to be assessed in large prospective randomised trials.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Multiplex real-time PCR FilmArray performance in the diagnosis of meningoencephalitis: lights and shadows
    Lopez, Nestor
    Cuesta, Genoveva
    Rodriguez-Vega, Sara
    Rosas, Enric
    Chumbita, Mariana
    Casals-Pascual, Climent
    Morata, Laura
    Vergara, Andrea
    Bodro, Marta
    Bosch, Jordi
    Herrera, Sabina
    Martinez, Jose Antonio
    Mensa, Josep
    Garcia-Vidal, Carolina
    Angeles Marcos, Maria
    Vila, Jordi
    Soriano, Alex
    Puerta-Alcalde, Pedro
    INFECTION, 2024, 52 (01) : 165 - 172
  • [32] Evaluation of the Magicplex™ Sepsis Real-Time Test for the Rapid Diagnosis of Bloodstream Infections in Adults
    Zboromyrska, Yuliya
    Cilloniz, Catia
    Cobos-Trigueros, Nazaret
    Almela, Manel
    Carlos Hurtado, Juan
    Vergara, Andrea
    Mata, Caterina
    Soriano, Alex
    Mensa, Josep
    Marco, Francesc
    Vila, Jordi
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9
  • [33] Real-time PCR for diagnosis of imported schistosomiasis
    Guegan, Helene
    Fillaux, Judith
    Charpentier, Elena
    Robert-Gangneux, Florence
    Chauvin, Pamela
    Guemas, Emilie
    Boissier, Jerome
    Valentin, Alexis
    Cassaing, Sophie
    Gangneux, Jean-Pierre
    Berry, Antoine
    Iriart, Xavier
    PLOS NEGLECTED TROPICAL DISEASES, 2019, 13 (09):
  • [34] Evaluation of a Multiplex Real-time PCR Assay for the Detection of Respiratory Viruses in Clinical Specimens
    Rheem, Insoo
    Park, Joowon
    Kim, Tae-Hyun
    Kim, Jong Wan
    ANNALS OF LABORATORY MEDICINE, 2012, 32 (06) : 399 - 406
  • [35] Development of a Multiplex Real-Time PCR for Determination of Apricot in Marzipan Using the Plexor System
    Schelm, Stefanie
    Haase, Ilka
    Fischer, Christin
    Fischer, Markus
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (02) : 516 - 522
  • [36] Diagnostic accuracy of a multiplex real-time PCR to predict Clostridium difficile ribotype 027
    Barra-Carrasco, Jonathan
    Hernandez-Rocha, Cristian
    Miranda-Cardenas, Camila
    Alvarez-Lobos, Manuel
    Guzman Duran, Ana Maria
    Paredes-Sabja, Daniel
    ANAEROBE, 2013, 22 : 115 - 117
  • [37] Multiplex real-time PCR using SYBR® GreenER™ for the detection of DNA allergens in food
    Pafundo, Simona
    Gulli, Mariolina
    Marmiroli, Nelson
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1831 - 1839
  • [38] A Real-Time PCR Antibiogram for Drug-Resistant Sepsis
    Waldeisen, John R.
    Wang, Tim
    Mitra, Debkishore
    Lee, Luke P.
    PLOS ONE, 2011, 6 (12):
  • [39] Comparison of real-time PCR and MassTag PCR for the multiplex detection of highly pathogenic agents
    Doellinger, Joerg
    Schroeder, Kati
    Witt, Natalie
    Heunemann, Carolin
    Nitsche, Andreas
    MOLECULAR AND CELLULAR PROBES, 2012, 26 (05) : 177 - 181
  • [40] Effect of an emergency department sepsis protocol on time to antibiotics in severe sepsis
    Francis, Marc
    Rich, Tom
    Williamson, Tyler
    Peterson, Daniel
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2010, 12 (04) : 303 - 310