Development and Evaluation of Quality Control Dried Blood Spot Materials in Newborn Screening for Lysosomal Storage Disorders

被引:100
|
作者
De Jesus, Victor R. [1 ]
Zhang, X. Kate [2 ]
Keutzer, Joan [2 ]
Bodamer, Olaf A. [3 ]
Muehl, Adolf [3 ]
Orsini, Joseph J. [4 ]
Caggana, Michele [4 ]
Vogt, Robert F. [1 ]
Hannon, W. Harry [1 ]
机构
[1] Ctr Dis Control & Prevent, Newborn Screening & Mol Biol Branch, Atlanta, GA 30341 USA
[2] Genzyme, Framingham, MA USA
[3] Univ Childrens Hosp, Div Biochem & Paediat Genet, Vienna, Austria
[4] Wadsworth Ctr, New York Dept Hlth, Albany, NY USA
关键词
TANDEM MASS-SPECTROMETRY; ENZYMATIC DIAGNOSIS; FILTER-PAPER; DISEASE;
D O I
10.1373/clinchem.2008.111864
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot studies to evaluate the incorporation of this method into their screening panels. We developed and evaluated dried blood spot (DBS) QC materials for LSDs and used the MS/MS method to investigate their suitability for LSD QC monitoring. METHODS: We incubated 3.2-mm punches from DBS controls for 20-24 h with assay cocktails containing substrate and internal standard. Using MS/MS, we quantified the resulting product and internal standard. Samples were run in triplicate for 3 consecutive days, and results were reported as product-to-internal standard ratios and enzyme activity units (mu mol/L/h). RESULTS: Enzyme activity interday imprecision (CV) for the high, medium, and low series were 3.4%-14.3% for galactocerebroside a-galactosidase, 6.8%-24.6% for acid a-galactosidase A, 7.36%-22.1% for acid sphingomyelinase, 6.2%-26.2% for acid alpha-glucocere-brosidase, and 7.0%-24.8% for lysosomal acid a-glucosidase (n = 9). In addition, DBS stored at -20 degrees and 4 degrees C showed minimal enzyme activity loss over a 187-d period. DBS stored at 37 degrees and 45 degrees C had lower activity values over the 187-day evaluation time. CONCLUSIONS: Suitable QC materials for newborn screening of LSDs were developed for laboratories performing DBS LSD screening. Good material linearity was observed, with goodness-of-fit values of 0.953 and higher. The QC materials may be used by screening laboratories that perform LSD analysis by MS and/or more conventional fluorescence-based screening methods. (C) 2008 American Association for Clinical Chemistry
引用
收藏
页码:158 / 164
页数:7
相关论文
共 48 条
  • [21] Consistency in the Assessment of Dried Blood Spot Specimen Size and Quality in U.K. Newborn Screening Laboratories
    Moat, Stuart J.
    Bonham, James R.
    Cavanagh, Christine
    Birch, Margaret
    Griffith, Caroline
    Shakespeare, Lynette
    Le Masurier, Clare
    Manfredonia, Claire
    Hird, Beverly
    Goddard, Philippa
    Smith, Sarah
    Wainwright, Laura
    Carling, Rachel S.
    Cundick, Jennifer
    Jenkinson, Fiona
    Collingwood, Catherine
    Flynn, Nick
    Taj, Nazia
    Mirzazadeh, Mehdi
    Ramgoolam, Tejswurree
    Robinson, Liz
    Headley, Amy
    Morgan, Tessa
    Elliman, David
    Tetlow, Lesley
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2024, 10 (03)
  • [22] Development of a fast LC-MS/MS protocol for combined measurement of six LSDs on dried blood spot in a newborn screening program
    Scolamiero, Emanuela
    Casetta, Bruno
    Malvagia, Sabrina
    Tanigawa, Tetsuo
    Forni, Giulia
    Funghini, Silvia
    Mura, Massimo
    Raspini, Francesca
    Poggiali, Sara
    la Marca, Giancarlo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 135 - 140
  • [23] Development of Flow Injection Analysis Method for the Second-Tier Estimation of Succinylacetone in Dried Blood Spot of Newborn Screening
    Varughese, Bijo
    Madrewar, Dnyanoba
    Polipalli, Sunil Kumar
    Kapoor, Seema
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2022, 37 (01) : 40 - 50
  • [24] Metabonomics of Newborn Screening Dried Blood Spot Samples: A Novel Approach in the Screening and Diagnostics of Inborn Errors of Metabolism
    Denes, Julia
    Szabo, Eszter
    Robinette, Steven L.
    Szatmari, Ildiko
    Szonyi, Laszlo
    Kreuder, Joachim G.
    Rauterberg, Ernst W.
    Takats, Zoltan
    ANALYTICAL CHEMISTRY, 2012, 84 (22) : 10113 - 10120
  • [25] Use of Tandem Mass Spectrometry for Newborn Screening of 6 Lysosomal Storage Disorders in a Korean Population
    Han, Minje
    Jun, Sun-Hee
    Song, Sang Hoon
    Park, Kyoung Un
    Kim, Jin Q.
    Song, Junghan
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2011, 31 (04): : 250 - 256
  • [26] Light and Shadows in Newborn Screening for Lysosomal Storage Disorders: Eight Years of Experience in Northeast Italy
    Gragnaniello, Vincenza
    Cazzorla, Chiara
    Gueraldi, Daniela
    Puma, Andrea
    Loro, Christian
    Porcu, Elena
    Stornaiuolo, Maria
    Miglioranza, Paolo
    Salviati, Leonardo
    Burlina, Alessandro P.
    Burlina, Alberto B.
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2024, 10 (01)
  • [27] Development, Validation, and Application of the Paya Hamsan Technologies Underivatized Newborn Screening Assay (PHUNSA) for Inborn Metabolic Disorders in Dried Blood Spot Samples from Iranian Infants
    Khodadadi, Azam
    Nanbedeh, Saber
    Joodaki, Mahsa
    Therrell, Bradford L.
    Gilany, Kambiz
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2025, 11 (01)
  • [28] Newborn Thyroid Screening: Influence of Pre-Analytic Variables on Dried Blood Spot Thyrotropin Measurement
    Butler, Allison M.
    Charoensiriwatana, Wiyada
    Krasao, Piamnukul
    Pankanjanato, Rotjanapan
    Thong-Ngao, Penpan
    Polson, Randall C.
    Snow, Gregory
    Ehrenkranz, Joel
    THYROID, 2017, 27 (09) : 1128 - 1134
  • [29] Development of dried blood spot quality control materials for adenosine deaminase severe combined immunodeficiency and an LC-MS/MS method for their characterization
    Young, Brian
    Hendricks, Jessica
    Foreman, David
    Pickens, C. Austin
    Hovell, Candice
    De Jesus, Victor R.
    Haynes, Christopher
    Petritis, Konstantinos
    CLINICAL MASS SPECTROMETRY, 2020, 17 : 4 - 11
  • [30] Rapid diagnostic testing procedures for lysosomal storage disorders: α-glucosidase and β-galactosidase assays on dried blood spots
    Gasparotto, Nicoletta
    Tomanin, Rosella
    Frigo, Anna Chiara
    Niizawa, Gabriela
    Pasquini, Elisabetta
    Blanco, Mariana
    Donati, Maria Alice
    Keutzer, Joan
    Zacchello, Franco
    Scarpa, Maurizio
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 38 - 41