Digital AFC Control of a Three-Phase Three-Wire Unity-Power-Factor PWM Rectifier

被引:0
作者
Orellana, Marcos [1 ]
Grino, Robert [1 ]
机构
[1] Univ Politecn Catalunya UPC, Inst Ind & Control Engn IOC, Barcelona, Spain
来源
2013 9TH ASIAN CONTROL CONFERENCE (ASCC) | 2013年
关键词
CONVERTERS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Nowadays, ac/dc power converters must fulfill more and more design constraints with respect to the electrical grid: harmonics reduction, operation with sags and swells and/or high grid impedances, etc. This is a challenge for the controllers, since they must be robust enough to ensure the stability of the system, specially when working the conditions are not the ideal ones. In this paper, a discrete-time control technique based on Adaptive Feed-forward Cancellation (AFC) is proposed for a three-phase three-wire rectifier with a LCL input filter. The continuous-time design method for resonators has been translated into the discrete-time domain. Thus, the controller has been entirely designed in discrete-time, avoiding approximate conversions of the controller from the continuous-time domain. Besides, the usual unit computational delay in sampled-data control systems is taken into account. The simulation results show that this kind of resonant control is not only robust, but also presents a good performance.
引用
收藏
页数:6
相关论文
共 14 条
  • [1] [Anonymous], 2008, REQ OFFSH GRID CONN
  • [2] [Anonymous], 2008, IFAC P VOLUMES, DOI DOI 10.3182/20080706-5-KR-1001.00769
  • [3] HARMONIC-GENERATION IN ADAPTIVE FEEDFORWARD CANCELLATION SCHEMES
    BODSON, M
    SACKS, A
    KHOSLA, P
    [J]. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1994, 39 (09) : 1939 - 1944
  • [4] A loop shaping perspective for tuning controllers with adaptive feedforward cancellation
    Byl, MF
    Ludwick, SJ
    Trumper, DL
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2005, 29 (01): : 27 - 40
  • [5] PI State Space Current Control of Grid-Connected PWM Converters With LCL Filters
    Dannehl, Joerg
    Fuchs, Friedrich Wilhelm
    Thogersen, Paul Bach
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (09) : 2320 - 2330
  • [6] Repetitive. based controller for a UPS inverter to compensate unbalance and harmonic distortion
    Escobar, G.
    Valdez, A. A.
    Leyva-Ramos, J.
    Mattavelli, P.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) : 504 - 510
  • [7] A repetitive-based controller for a power factor precompensator
    Escobar, Gerardo
    Hernandez-Gomez, Michael
    Martinez, Panfilo R.
    Martinez-Montejano, Misael F.
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2007, 54 (09) : 1968 - 1976
  • [8] INTERNAL MODEL PRINCIPLE OF CONTROL-THEORY
    FRANCIS, BA
    WONHAM, WM
    [J]. AUTOMATICA, 1976, 12 (05) : 457 - 465
  • [9] Digital repetitive control of a three-phase four-wire shunt active filter
    Grino, Robert
    Cardoner, Rafael
    Costa-Castello, Ramon
    Fossas, Enric
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (03) : 1495 - 1503
  • [10] Orellana M, 2012, IEEE IND ELEC, P2378, DOI 10.1109/IECON.2012.6388871