Frequency doubling technology perimetry with the Humphrey Matrix 30-2 test

被引:40
作者
Brusini, P
Salvetat, ML
Zeppieri, M
Parisi, L
机构
[1] Santa Maria Misericordia Hosp, Dept Ophthalmol, I-33100 Udine, Italy
[2] Univ Udine, Dept Ophthalmol, I-33100 Udine, Italy
关键词
frequency doubling technology; Humphrey Matrix; standard automated perimetry; primary open-angle glaucoma; ocular hypertension;
D O I
10.1097/00061198-200604000-00001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the Humphrey Matrix 30-2 test in detecting functional glaucomatous damage. Patients and Methods: One eye in each of 60 healthy individuals, 108 patients with ocular hypertension (OHT), and 150 patients with preperimetric (48) or perimetric (102) high-tension primary open-angle glaucoma (POAG) were considered. Visual fields were assessed by the standard automated perimetry (SAP) Humphrey Field Analyzer 30-2, frequency doubling technology (FDT) N-30, and Humphrey Matrix 30-2 tests. Significantly abnormal points in the pattern deviation probability plot, testing time, sensitivity, specificity, and area tinder the receiver operating characteristic curve of the FDT tests were evaluated. Results: FDT revealed a significantly greater percentage of depressed points than did SAP in OHT and preperimetric POAG eyes. The FDT-N-30 test showed a significantly greater percentage of areas with P < 5% in the OHT, preperimetric POAG, and early POAG groups. The Matrix-30-2 test provided an area under the receiver operating characteristic curve slightly lower than the FDT-N-30 test in the preperimetric POAG group, and significantly greater in the perimetric POAG group. Conclusions: FDT perimetry appeared more sensitive than SAP in detecting early glaucomatous VF loss. The FDT-N-30 test showed a slightly higher ability to detect early glaucomatous damage in patients at risk for the development of glaucoma, whereas the Matrix-30-2 test provided a more detailed characterization of the glaucomatous VF loss pattern, although it required 30% more time.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 36 条
[1]  
Anderson AJ, 2002, INVEST OPHTH VIS SCI, V43, P398
[2]   Characteristics of the normative database for the Humphrey Matrix perimeter [J].
Anderson, AJ ;
Johnson, CA ;
Fingeret, M ;
Keltner, JL ;
Spry, PGD ;
Wall, M ;
Werner, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1540-1548
[3]  
Anderson Andrew J, 2003, Ophthalmol Clin North Am, V16, P213, DOI 10.1016/S0896-1549(03)00011-7
[4]  
ANDERSON D, 1999, AUTOMATED STATIC PER, P117
[5]   Short wavelength automated perimetry, frequency doubling technology perimetry, and pattern electroretinography for prediction of progressive glaucomatous standard visual field defects [J].
Bayer, AU ;
Erb, C .
OPHTHALMOLOGY, 2002, 109 (05) :1009-1017
[6]  
BECK RW, 1985, OPHTHALMOLOGY, V92, P77
[7]   Staging of functional damage in glaucoma using frequency doubling technology [J].
Brusini, P ;
Tosoni, C .
JOURNAL OF GLAUCOMA, 2003, 12 (05) :417-426
[8]  
Brusini P, 1998, ACTA OPHTHALMOL SCAN, V76, P23
[9]  
Brusini P, 1996, Eur J Ophthalmol, V6, P402
[10]  
BURGANSKY Z, 2005, INVEST OPHTH VIS SCI, V46, P3725