Purpose: To assess the Humphrey Matrix 30-2 test in detecting functional glaucomatous damage. Patients and Methods: One eye in each of 60 healthy individuals, 108 patients with ocular hypertension (OHT), and 150 patients with preperimetric (48) or perimetric (102) high-tension primary open-angle glaucoma (POAG) were considered. Visual fields were assessed by the standard automated perimetry (SAP) Humphrey Field Analyzer 30-2, frequency doubling technology (FDT) N-30, and Humphrey Matrix 30-2 tests. Significantly abnormal points in the pattern deviation probability plot, testing time, sensitivity, specificity, and area tinder the receiver operating characteristic curve of the FDT tests were evaluated. Results: FDT revealed a significantly greater percentage of depressed points than did SAP in OHT and preperimetric POAG eyes. The FDT-N-30 test showed a significantly greater percentage of areas with P < 5% in the OHT, preperimetric POAG, and early POAG groups. The Matrix-30-2 test provided an area under the receiver operating characteristic curve slightly lower than the FDT-N-30 test in the preperimetric POAG group, and significantly greater in the perimetric POAG group. Conclusions: FDT perimetry appeared more sensitive than SAP in detecting early glaucomatous VF loss. The FDT-N-30 test showed a slightly higher ability to detect early glaucomatous damage in patients at risk for the development of glaucoma, whereas the Matrix-30-2 test provided a more detailed characterization of the glaucomatous VF loss pattern, although it required 30% more time.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [1] Learning effect of Humphrey Matrix Frequency Doubling Technology perimetry in patients with ocular hypertension
    Centofanti, Marco
    Fogagnolo, Paolo
    Oddone, Francesco
    Orzalesi, Nicola
    Vetrugno, Michele
    Manni, Gianluca
    Rossetti, Luca
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 436 - 441
  • [2] The Effect of Myopic Optical Defocus on the Humphrey Matrix 30-2 Threshold Test
    Kim, Jae Hui
    Kee, Changwon
    JOURNAL OF GLAUCOMA, 2010, 19 (04) : 257 - 263
  • [3] Learning effect in visual field testing of healthy subjects using Humphrey Matrix frequency doubling technology perimetry
    Pierre-Filho, P. de T.
    Gomes, P. R.
    Pierre, E. T.
    Pierre, L. M.
    EYE, 2010, 24 (05) : 851 - 856
  • [4] Learning effect in visual field testing of healthy subjects using Humphrey Matrix frequency doubling technology perimetry
    P de T Pierre-Filho
    P R Gomes
    E T Pierre
    L M Pierre
    Eye, 2010, 24 : 851 - 856
  • [5] Comparison of Three Visual Field Tests in Children: Frequency Doubling Test, 24-2 and 30-2 SITA Perimetry
    Han, Sangyoun
    Baek, Seung-Hee
    Kim, Ungsoo Samuel
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (05) : 647 - 650
  • [6] Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children
    Kocabeyoglu, Sibel
    Uzun, Salih
    Mocan, Mehmet Cem
    Bozkurt, Banu
    Irkec, Murat
    Orhan, Mehmet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (10) : 576 - 579
  • [7] Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma
    Pierre-Filho, Paulo De Tarso
    Gomes, Paulo R. P.
    Pierre, Erika T. L.
    Pierre, Leandro M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 538 - 541
  • [8] The influence of learning effect on frequency doubling technology perimetry (Matrix)
    Contestabile, Maria Teresa
    Perdicchi, Andrea
    Amodeo, Stefano
    Recupero, Vincenzo
    Recupero Santi, Maria
    JOURNAL OF GLAUCOMA, 2007, 16 (03) : 297 - 301
  • [9] Rarebit perimetry and frequency doubling technology in patients with ocular hypertension
    Corallo, G.
    Iester, M.
    Scotto, R.
    Calabria, G.
    Traverso, C. E.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (02) : 205 - 211
  • [10] Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma
    Clement, C. I.
    Goldberg, I.
    Healey, P. R.
    Graham, S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 582 - 588