Changes in Frequency-Doubling Perimetry in Patients with Type I Diabetes prior to Retinopathy

被引:14
|
作者
Pinilla, Isabel [1 ]
Ferreras, Antonio [2 ]
Idoipe, Miriam [2 ]
Sanchez-Cano, Ana I. [3 ]
Perez-Garcia, Diana [1 ]
Herrera, Laura X. [1 ]
Pinilla, Maria J. [4 ]
Abecia, Emilio [2 ]
机构
[1] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Ophthalmol, Zaragoza 50009, Spain
[2] Miguel Servet Univ Hosp, Aragon Hlth Sci Inst, Zaragoza 50009, Spain
[3] Univ Zaragoza, Dept Appl Phys, E-50009 Zaragoza, Spain
[4] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Cardiol, Zaragoza 50009, Spain
关键词
VISUAL EVOKED-POTENTIALS; WAVELENGTH AUTOMATED PERIMETRY; CONTRAST SENSITIVITY; TECHNOLOGY PERIMETRY; FIELD DEFECTS; IDDM; ELECTRORETINOGRAM; ABNORMALITIES; RESPONSES; GLAUCOMA;
D O I
10.1155/2013/341269
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes. Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups. Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group (P = 0.875). The mean period from the onset of diabetes was 12.6 +/- 6.7 years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group (P = 0.035). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052; P = 0.017). Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] CHANGES IN TOTAL AND INNER RETINAL THICKNESSES IN TYPE 1 DIABETES WITH NO RETINOPATHY AFTER 8 YEARS OF FOLLOW-UP
    Pinilla, Isabel
    Idoipe, Miriam
    Perdices, Lorena
    Sanchez-Cano, Ana
    Acha, Javier
    Isabel Lopez-Galvez, Maria
    Cuenca, Nicolas
    Abecia, Emilio
    Orduna-Hospital, Elvira
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (07): : 1379 - 1386
  • [32] The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Jansonius, Nomdo M.
    Heeg, Govert P.
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 429 - 432
  • [33] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09) : 808 - 811
  • [34] Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma
    Pierre-Filho, Paulo De Tarso
    Gomes, Paulo R. P.
    Pierre, Erika T. L.
    Pierre, Leandro M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 538 - 541
  • [35] Usefulness of 10-2 Matrix Frequency Doubling Technology Perimetry for Detecting Central Visual Field Defects in Preperimetric Glaucoma Patients
    Jung, Younhea
    Park, Hae-Young L.
    Park, Yi Ryeung
    Park, Chan Kee
    SCIENTIFIC REPORTS, 2017, 7
  • [36] Correlation between early retinal nerve fiber layer loss and visual field loss determined by three different perimetric strategies: white-on-white, frequency-doubling, or flicker-defined form perimetry
    Prokosch, Verena
    Eter, Nicole
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (10) : 1599 - 1606
  • [37] Visual Field Tests for Glaucoma Patients With Initial Macular Damage: Comparison Between Frequency-doubling Technology and Standard Automated Perimetry Using 24-2 or 10-2 Visual Fields
    Park, Hae-Young Lopilly
    Lee, Jiyoung
    Park, Chan Kee
    JOURNAL OF GLAUCOMA, 2018, 27 (07) : 627 - 634
  • [38] New perimetric techniques - A comparison between rarebit and frequency doubling technology perimetry in normal subjects and glaucoma patients
    Martin, L
    Wanger, P
    JOURNAL OF GLAUCOMA, 2004, 13 (04) : 268 - 272
  • [39] The groningen longitudinal glaucoma study III. The predictive value of frequency-doubling perimetry and GDx nerve fibre analyser test results for the development of glaucomatous visual field loss
    G P Heeg
    N M Jansonius
    Eye, 2009, 23 : 1647 - 1652
  • [40] Continuing Medical Education: Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma
    Horn, F. K.
    Mardin, C. Y.
    Bendschneider, D.
    Juenemann, A. G.
    Adler, W.
    Tornow, R. P.
    EYE, 2011, 25 (01) : 17 - 29