Changes in Frequency-Doubling Perimetry in Patients with Type I Diabetes prior to Retinopathy

被引:14
|
作者
Pinilla, Isabel [1 ]
Ferreras, Antonio [2 ]
Idoipe, Miriam [2 ]
Sanchez-Cano, Ana I. [3 ]
Perez-Garcia, Diana [1 ]
Herrera, Laura X. [1 ]
Pinilla, Maria J. [4 ]
Abecia, Emilio [2 ]
机构
[1] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Ophthalmol, Zaragoza 50009, Spain
[2] Miguel Servet Univ Hosp, Aragon Hlth Sci Inst, Zaragoza 50009, Spain
[3] Univ Zaragoza, Dept Appl Phys, E-50009 Zaragoza, Spain
[4] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Cardiol, Zaragoza 50009, Spain
关键词
VISUAL EVOKED-POTENTIALS; WAVELENGTH AUTOMATED PERIMETRY; CONTRAST SENSITIVITY; TECHNOLOGY PERIMETRY; FIELD DEFECTS; IDDM; ELECTRORETINOGRAM; ABNORMALITIES; RESPONSES; GLAUCOMA;
D O I
10.1155/2013/341269
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes. Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups. Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group (P = 0.875). The mean period from the onset of diabetes was 12.6 +/- 6.7 years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group (P = 0.035). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052; P = 0.017). Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Detection of ocular disease by a vision-centre technician and the role of frequency-doubling technology perimetry in this setting
    Thomas, Ravi
    Naveen, Shoba
    Nirmalan, Praveen K.
    Parikh, Rajul
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) : 214 - 218
  • [22] Within-test variability of frequency-doubling perimetry using a 24-2 test pattern
    Spry, PGD
    Johnson, CA
    JOURNAL OF GLAUCOMA, 2002, 11 (04) : 315 - 320
  • [23] Correlation of Frequency-doubling Perimetry With Retinal Nerve Fiber Layer Thickness and Optic Disc Size in Ocular Hypertensives and Glaucoma Suspects
    Kaushik, Sushmita
    Pandav, Surinder Singh
    Ichhpujani, Parul
    Gupta, Amod
    JOURNAL OF GLAUCOMA, 2011, 20 (06) : 366 - 370
  • [24] Learning effect and measurement variability in frequency-doubling technology perimetry in chronic open-angle glaucoma
    Matsuo, H
    Tomita, G
    Suzuki, Y
    Araie, M
    JOURNAL OF GLAUCOMA, 2002, 11 (06) : 467 - 473
  • [25] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [26] The groningen longitudinal glaucoma study III. The predictive value of frequency-doubling perimetry and GDx nerve fibre analyser test results for the development of glaucomatous visual field loss
    Heeg, G. P.
    Jansonius, N. M.
    EYE, 2009, 23 (08) : 1647 - 1652
  • [27] Detecting glaucoma with frequency-doubling technology perimetry - A comparison between N-30 and C-20 screening programs
    Fogagnolo, P
    Mazzolani, F
    Rossetti, L
    Orzalesi, N
    JOURNAL OF GLAUCOMA, 2005, 14 (06) : 485 - 491
  • [28] Screening for Patients with Mild Alzheimer Disease Using Frequency Doubling Technology Perimetry
    Aykan, Umit
    Akdemir, M. Orcun
    Yildirim, Ozlem
    Varlibas, Figen
    NEURO-OPHTHALMOLOGY, 2013, 37 (06) : 239 - 246
  • [29] Multifocal and pattern-reversal visual evoked potentials vs. automated perimetry frequency-doubling technology matrix in optic neuritis
    Nebbioso, Marcella
    Steigerwalt, Robert D.
    Pecori-Giraldi, Jose
    Vingolo, Enzo M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (02) : 59 - 64
  • [30] Learning effect of Humphrey Matrix Frequency Doubling Technology perimetry in patients with ocular hypertension
    Centofanti, Marco
    Fogagnolo, Paolo
    Oddone, Francesco
    Orzalesi, Nicola
    Vetrugno, Michele
    Manni, Gianluca
    Rossetti, Luca
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 436 - 441