Changes in Frequency-Doubling Perimetry in Patients with Type I Diabetes prior to Retinopathy

被引:14
|
作者
Pinilla, Isabel [1 ]
Ferreras, Antonio [2 ]
Idoipe, Miriam [2 ]
Sanchez-Cano, Ana I. [3 ]
Perez-Garcia, Diana [1 ]
Herrera, Laura X. [1 ]
Pinilla, Maria J. [4 ]
Abecia, Emilio [2 ]
机构
[1] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Ophthalmol, Zaragoza 50009, Spain
[2] Miguel Servet Univ Hosp, Aragon Hlth Sci Inst, Zaragoza 50009, Spain
[3] Univ Zaragoza, Dept Appl Phys, E-50009 Zaragoza, Spain
[4] Hosp Clin Univ Lozano Blesa, Aragon Hlth Sci Inst, Dept Cardiol, Zaragoza 50009, Spain
关键词
VISUAL EVOKED-POTENTIALS; WAVELENGTH AUTOMATED PERIMETRY; CONTRAST SENSITIVITY; TECHNOLOGY PERIMETRY; FIELD DEFECTS; IDDM; ELECTRORETINOGRAM; ABNORMALITIES; RESPONSES; GLAUCOMA;
D O I
10.1155/2013/341269
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes. Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups. Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group (P = 0.875). The mean period from the onset of diabetes was 12.6 +/- 6.7 years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group (P = 0.035). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052; P = 0.017). Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Abdullah, Siti Nurliyana
    Sanderson, Gordon F.
    Husni, Mohd Aziz
    Maddess, Ted
    DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 45 - 55
  • [2] Screening for glaucomatous visual field loss with frequency-doubling perimetry
    Johnson, CA
    Samuels, SJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (02) : 413 - 425
  • [3] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Siti Nurliyana Abdullah
    Gordon F. Sanderson
    Mohd Aziz Husni
    Ted Maddess
    Documenta Ophthalmologica, 2020, 141 : 45 - 55
  • [4] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [5] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [6] Agreement between frequency-doubling technology perimetry and Heidelberg retinal tomography 3
    Lee, Na Young
    Chung, Hye Jin
    Park, Chan Kee
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (03) : 252 - 256
  • [7] Visual Field Progression With Frequency-Doubling Matrix Perimetry and Standard Automated Perimetry in Patients With Glaucoma and in Healthy Controls
    Redmond, Tony
    O'Leary, Neil
    Hutchison, Donna M.
    Nicolela, Marcelo T.
    Artes, Paul H.
    Chauhan, Balwantray C.
    JAMA OPHTHALMOLOGY, 2013, 131 (12) : 1565 - 1572
  • [8] THE ROLE OF FREQUENCY DOUBLING TECHNOLOGY PERIMETRY IN EARLY DETECTION OF DIABETIC RETINOPATHY
    Bradvica, Mario
    Biuk, Dubravka
    Bradvica, Ivanka Stenc
    Vinkovic, Maja
    Cerovski, Branimir
    Barac, Ivona
    ACTA CLINICA CROATICA, 2020, 59 (01) : 10 - 18
  • [9] Retinal Sensitivity in Patients with Type I Diabetes without Retinopathy or with Minor Retinal Changes
    Pinilla, I.
    Sanchez-Cano, A.
    Ferreras, A.
    Acha, J.
    Perez-Garcia, D.
    Ibanez-Alperte, J.
    Abecia, E.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2016, 124 (10) : 613 - 617
  • [10] Measuring Visual Function in Age-Related Macular Degeneration with Frequency-Doubling (Matrix) Perimetry
    Anderson, Andrew John
    Johnson, Chris A.
    Werner, John S.
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (07) : 806 - 815