A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses

被引:48
作者
Lee, Jun Kyu [1 ]
Lee, Kyu Taek [2 ]
Choi, E. Ryoung [2 ]
Jang, Tae Hoon [2 ]
Jang, Kee-Taek [3 ]
Lee, Jong Kyun [2 ]
Lee, Kwang Hyuck [2 ]
机构
[1] Dongguk Univ, Ilsan Hosp, Dept Internal Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Dept Med, Div Gastroenterol, Samsung Med Ctr,Sch Med, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Dept Pathol, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
关键词
22-gauge; 25-gauge; endoscopic ultrasound; fine needle aspiration; prospective trial; EUS-FNA; HEMOSUCCUS-PANCREATICUS; RETROSPECTIVE ANALYSIS; CYSTIC LESIONS; TRUCUT NEEDLE; DIAGNOSIS; COMPLICATIONS; FREQUENCY; 19-GAUGE; UTILITY;
D O I
10.3109/00365521.2013.786127
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives. Endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) is widely performed for pancreatic masses. The 25-gauge needle (25G) might be easier to be manipulated and expected to be associated with fewer complications since it is thinner and more flexible than the 22-gauge needle (22G) although obtaining adequate specimens is questioned. In this randomized trial, the authors tried to compare prospectively 25G and 22G in diagnostic accuracy, manipulability from the operator's viewpoint and procedure-related complications. Material and methods. A total of 188 consecutive patients undergoing EUS-FNA for solid or cystic pancreatic masses were consecutively enrolled and 94 patients were randomized to either 25G or 22G group, respectively. Results. Baseline characteristics were similar except that more masses of 25G group were located in the head or uncinate process of pancreas than those from 22G group. Although there was no difference in diagnostic accuracy (89.4% vs. 88.3% with p = 0.82), 25G was easier to be manipulated (p = 0.004) and related with fewer procedure-related complications (10.6% vs. 3.2% with p = 0.004). Conclusions. 25G can be chosen in preference to 22G when performing pancreatic EUS-FNA because 25G was significantly superior to 22G in terms of manipulability and complications although both were effective for accurate diagnosis.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 29 条
  • [11] Endoscopic ultrasound-guided fine-needle aspiration in focal pancreatic lesions:: A prospective intraindividual comparison of two needle assemblies
    Fritscher-Ravens, A
    Topalidis, T
    Bobrowski, C
    Krause, C
    Thonke, E
    Jäckle, S
    Soehendra, N
    [J]. ENDOSCOPY, 2001, 33 (06) : 484 - 490
  • [12] How to do pancreatic mass FNA
    Harris, Michael D.
    Buscaglia, Jonathan M.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 71 (04) : 825 - 826
  • [13] Puncture of solid pancreatic tumors guided by endoscopic ultrasonography: A pilot study series comparing Trucut and 19-gauge and 22-gauge aspiration needles
    Itoi, T
    Itokawa, F
    Sofuni, A
    Nakamura, K
    Tsuchida, A
    Yamao, K
    Kawai, T
    Moriyasu, F
    [J]. ENDOSCOPY, 2005, 37 (04) : 362 - 366
  • [14] ASGE guideline: the role of endoscopy in the diagnosis and the management of cystic lesions and inflammatory fluid collections of the pancreas
    Jacobson, BC
    Baron, TH
    Adler, DG
    Davila, RE
    Egan, J
    Hirota, WK
    Leighton, JA
    Qureshi, W
    Rajan, E
    Zuckerman, MJ
    Fanelli, R
    Wheeler-Harbaugh, J
    Faigel, DO
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 61 (03) : 363 - 370
  • [15] Hemosuccus pancreaticus after endoscopic ultrasound-guided fine needle aspiration of a pancreatic cyst
    Keswani, R. N.
    [J]. ENDOSCOPY, 2010, 42 : E79 - E79
  • [16] Endoscopic ultrasound-guided pancreatic duct aspiration: Diagnostic yield and safety
    Lai, R
    Stanley, MW
    Bardales, R
    Linzie, B
    Mallery, S
    [J]. ENDOSCOPY, 2002, 34 (09) : 715 - 720
  • [17] EUS-guided trucut needle biopsies in patients with solid pancreatic masses: a prospective study
    Larghi, A
    Verna, EC
    Stavropoulos, SN
    Rotterdam, H
    Lightdale, CJ
    Stevens, PD
    [J]. GASTROINTESTINAL ENDOSCOPY, 2004, 59 (02) : 185 - 190
  • [18] Blinded Prospective Comparison of the Performance of 22-Gauge and 25-Gauge Needles in Endoscopic Ultrasound-Guided Fine Needle Aspiration of the Pancreas and Peri-pancreatic Lesions
    Lee, Jeffrey H.
    Stewart, John
    Ross, William A.
    Anandasabapathy, Sharmila
    Xiao, Lianchun
    Staerkel, Gregg
    [J]. DIGESTIVE DISEASES AND SCIENCES, 2009, 54 (10) : 2274 - 2281
  • [19] EUS-guided fine needle aspiration of pancreatic cysts: A retrospective analysis of complications and their predictors
    Lee, LS
    Saltzman, JR
    Bounds, BC
    Poneros, JM
    Brugge, WR
    Thompson, CC
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2005, 3 (03) : 231 - 236
  • [20] Reddymasu S, 2011, J PANCREAS, V12, P489