In vitro and in vivo studies of 17O NMR sensitivity at 9.4 and 16.4 T

被引:22
|
作者
Lu, Ming [1 ]
Zhang, Yi [1 ]
Ugurbil, Kamil [1 ]
Chen, Wei [1 ]
Zhu, Xiao-Hong [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
in vivo 17O magnetic resonance spectroscopy; cerebral metabolic rate of oxygen consumption; signal-to-noise ratio; sensitivity; high field; CEREBRAL METABOLIC-RATE; O-17; NMR; OXYGEN-CONSUMPTION; HIGH-FIELD; BLOOD-FLOW; RAT-BRAIN; INHALATION; MRI;
D O I
10.1002/mrm.24386
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo 17O magnetic resonance spectroscopy has been successfully applied for imaging the cerebral metabolic rate of oxygen consumption through the detection of metabolically produced H217O from the inhaled 17O-labeled oxygen in animals at high field. In this study, we compared the 17O sensitivity for detecting natural abundance H217O signals from a phantom solution and rat brains at 9.4 and 16.4 T. The 17O signal-to-noise ratio measured at 16.4 T was 2.9- and 2.7-2.8-fold higher than that at 9.4 T for the phantom and rat brain studies, respectively. Similarly, three-dimensional 17O magnetic resonance spectroscopy imaging data showed a more than 2.7-fold higher signal-to-noise ratio in the central rat brain region at 16.4 T than that at 9.4 T. The substantial 17O signal-to-noise ratio gain at ultrahigh field significantly improved the reliability for imaging the cerebral metabolic rate of oxygen consumption and will provide an opportunity for in vivo assessment of altered oxidative metabolism associated with brain functions and neurological diseases. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1523 / 1527
页数:5
相关论文
共 50 条
  • [1] In vivo measurement of CBF using 17O NMR signal of metabolically produced H217O as a perfusion tracer
    Zhu, Xiao-Hong
    Zhang, Yi
    Wiesner, Hannes M.
    Ugurbil, Kamil
    Chen, Wei
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 309 - 314
  • [2] 17O NMR studies on α-diamides
    Cerioni, G
    Giumanini, AG
    Verardo, G
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 1998, 11 (06) : 387 - 391
  • [3] 17O NMR studies on dialkoxy disulfides
    Cerioni, G
    Plumitallo, A
    MAGNETIC RESONANCE IN CHEMISTRY, 1998, 36 (06) : 461 - 462
  • [4] In vivo 17O NMR approaches for brain study at high field
    Zhu, XH
    Zhang, NY
    Zhang, Y
    Zhang, XL
    Ugurbil, K
    Chen, W
    NMR IN BIOMEDICINE, 2005, 18 (02) : 83 - 103
  • [5] Natural abundance 17O NMR spectroscopy of rat brain in vivo
    de Graaf, Robin A.
    Brown, Peter B.
    Rothman, Douglas L.
    Behar, Kevin L.
    JOURNAL OF MAGNETIC RESONANCE, 2008, 193 (01) : 63 - 67
  • [6] In vivo 17O MRS imaging - Quantitative assessment of regional oxygen consumption and perfusion rates in living brain
    Zhu, Xiao-Hong
    Chen, Wei
    ANALYTICAL BIOCHEMISTRY, 2017, 529 : 171 - 178
  • [7] 17O Relaxation Times in the Rat Brain at 16.4 Tesla
    Wiesner, Hannes M.
    Balla, David Z.
    Shajan, G.
    Scheffler, Klaus
    Ugurbil, Kamil
    Chen, Wei
    Uludag, Kamil
    Pohmann, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 1886 - 1893
  • [8] 17O NMR studies of low silicate zeolites
    Freude, D
    Loeser, T
    Michel, D
    Pingel, U
    Prochnow, D
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2001, 20 (1-2) : 46 - 60
  • [9] 17O MQMAS NMR studies of zeolite HY
    Peng, Luming
    Huo, Hua
    Gan, Zhehong
    Grey, Clare P.
    MICROPOROUS AND MESOPOROUS MATERIALS, 2008, 109 (1-3) : 156 - 162
  • [10] Quantitative 17O imaging towards oxygen consumption study in tumor bearing mice at 7 T
    Narazaki, Michiko
    Kanazawa, Yoko
    Koike, Sachiko
    Ando, Koichi
    Ikehira, Hiroo
    MAGNETIC RESONANCE IMAGING, 2013, 31 (05) : 643 - 650