An implantable bioimpedance monitor using 2.45 GHz band for telemetry

被引:8
|
作者
Bogonez-Franco, Paco [1 ]
Nescolarde, Lexa [1 ]
Galvez-Monton, Carolina [2 ]
Bragos, Ramon [1 ]
Rosell-Ferrer, Javier [1 ]
机构
[1] Tech Univ Catalonia UPC, Dept Elect Engn, Barcelona 08034, Spain
[2] Hosp Badalona Germans Trias & Pujol, IGTP, Serv Cardiol, Heart Failure & Cardiac Regenerat ICREC Res Progr, Barcelona, Spain
关键词
implantable; bioimpedance; ZigBee; monitor; BIOELECTRICAL-IMPEDANCE; REJECTION; DEVICE; SYSTEM;
D O I
10.1088/0967-3334/34/1/1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes a multi-frequency single-channel electrical implantable bioimpedance monitor (35 mm x 35 mm x 10 mm, weight 52 g) powered by a NiMH battery. By using the tetrapolar method and injecting 10 mu A(peak), the monitor is capable of measuring at 14 different frequencies, from 100 Hz to 200 kHz. It contains a ZigBee transceiver to monitor the measurements performed, and has an embedded memory for backing up the data. RC networks and in-situ heart excised tissues were used to test the system. When measuring a full spectrum every 5 min, 35 days of autonomy are possible due to the low power consumption of the monitor. Temperature drift was estimated by short-term and long-term measurements. Temperature cycling was used to measure modulus and phase angle stability. The result was a very low effect on a modulus decrease of 2.34 Omega, with respect to an impedance of 322 Omega, at 100 Hz and a phase angle increase of 1.1 degrees, at 200 kHz. In addition, measurement errors were bigger at low frequencies because of the high impedance of the electrodes used, which was higher than 10 k Omega at frequencies below 1 kHz.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 32 条
  • [1] Implantable Bioimpedance Monitor using ZigBee
    Bogonez-Franco, P.
    Bragos, R.
    Bayes-Genis, A.
    Rosell-Ferrer, J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4868 - +
  • [2] Experimental Wireless Link and SAR Assessments of an Implantable PIFA for Biotelemetry in the 2.45 GHz Band
    Zulkefli, Muhammad Solihin
    Zhang, Kai
    Sarestoniemi, Mariella
    Myllymaki, Sami
    Whittow, William G. G.
    Yan, Sen
    Soh, Ping Jack
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2023, 7 (03): : 281 - 289
  • [3] A Novel Wideband and Multi-band Implantable Antenna Design for Biomedical Telemetry
    Behih, Mohamed
    Bouttout, Farid
    Fortaki, Tarek
    Dumond, Christophe
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2022, 37 (04): : 441 - 457
  • [4] A Miniaturized Triple-Band Implantable Antenna System for Bio-Telemetry Applications
    Zada, Muhammad
    Yoo, Hyoungsuk
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2018, 66 (12) : 7378 - 7382
  • [6] Comparison of an implantable telemetry device and an oscillometric monitor for measurement of blood pressure in anaesthetized and unrestrained green iguanas (Iguana iguana)
    Chinnadurai, Sathya K.
    DeVoe, Ryan
    Koenig, Amie
    Gadsen, Nadia
    Ardente, Amanda
    Divers, Stephen J.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2010, 37 (05) : 434 - 439
  • [7] An ultra - wideband compact meander line antenna for brain implants and biotelemetry applications in the 2.45 GHz ISM band
    Mohan, Archana
    Kumar, Niraj
    RESULTS IN ENGINEERING, 2024, 24
  • [8] RF energy harvesting using a compact rectenna with an antenna array at 2.45 GHz for IoT applications
    Pramono, Subuh
    Shidiq, Dwiki Dimas
    Ibrahim, Muhammad Hamka
    Adriyanto, Feri
    Hikmaturokhman, Alfin
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2021, 72 (03): : 159 - 167
  • [9] Non-invasive glucose monitor based on electric bioimpedance using AFE4300
    Raul Sulla, T.
    Jesus Talavera, S.
    Elvis Supo, C.
    Andres Montoya, A.
    PROCEEDINGS OF THE 2019 IEEE XXVI INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL ENGINEERING AND COMPUTING (INTERCON), 2019,
  • [10] A Wideband RF Link at the 5.8 GHz ISM band for Multi-Channel Neural Telemetry for Small Animals
    Roy, Sabyasachi
    Wang, Xiaoqin
    Olson, Andy
    Snider, Ross K.
    2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 106 - 109