Plasma immersion ion implantation (PIII) influence on Ti-6Al-4V alloy: Frequency effect

被引:16
|
作者
Oliveira, V. M. C. A. [1 ]
Cioffi, M. O. H. [1 ]
Barboza, M. J. R. [2 ]
Landers, R. [3 ]
Schmitt, B. [4 ]
Tapia, D. C. A. R. [5 ]
Voorwald, H. J. C. [1 ]
机构
[1] Univ Estadual Paulista, Fac Engn Guaratingueta, Sao Paulo, Brazil
[2] Univ Sao Paulo, Escola Engn Lorena, Sao Paulo, Brazil
[3] Univ Estadual Campinas, Inst Fis Gleb Wataghin, Campinas, SP, Brazil
[4] Univ Bayreuth, Fac Engn Sci, Bayreuth, Germany
[5] Univ Nacl Ingn, Lima, Peru
基金
巴西圣保罗研究基金会;
关键词
Ti-6Al-4V alloy; PIII treatment; Frequency; Axial fatigue; AISI; 4340; STEEL; FATIGUE-STRENGTH; BENDING FATIGUE; STATISTICAL-ANALYSIS; CORROSION BEHAVIOR; TITANIUM-ALLOYS; TI6AL4V ALLOY; NITROGEN; TEMPERATURE; MICROSTRUCTURE;
D O I
10.1016/j.ijfatigue.2017.12.016
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The plasma immersion ion implantation treatment (PIII) acts to increase mechanical resistance with solid solution formation, new phases and defects inclusion, besides chemical and residual stress profile modification. Ti-6Al-4V alloy presents poor tribological properties and high affinity with interstitial elements, such as nitrogen and oxygen, this makes it more reactive at high temperatures. This paper aims to study Ti-6Al-4V alloy fatigue behavior subjected to nitrogen addition by plasma immersion ion implantation. It was investigated the frequency parameter influence on fatigue resistance. Ti-6Al-4V alloy was PIII treated with voltage equal to 9.5 kV, frequencies varying between 1000 and 1500 Hz and submitted to axial fatigue tests. Axial fatigue tests were performed, at room temperature and R = 0.1. Ti-6Al-4V alloy fatigue results were supported by Weibull statistics analysis. Ti-6Al-4V alloy microstructural analysis showed equiaxed alpha + beta grains. Weibull analysis at untreated condition presented m values greater than 1, indicating reliability and uniformity. For a lifetime of 10(7) cycles, fatigue resistance was equal to 829 MPa for untreated condition, 644, 767 and 417 MPa, for f = 1000, 1200 and 1500 Hz, respectively. The nitrogen-based compounds were detected only at the condition where f = 1200 Hz. Thus, the combination of PIII treatment parameters, when f = 1200 Hz, hindered crack nucleation and increasing fatigue resistance of treated Ti-6Al-4V alloy when compared with the other two treatment conditions.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 50 条
  • [31] The Effect of Plasma Nitriding on the Fatigue Behavior of the Ti-6Al-4V Alloy
    de Castro, Michele C. B.
    Couto, Antonio A.
    Almeida, Gisele F. C.
    Massi, Marcos
    de Lima, Nelson B.
    da Silva Sobrinho, Argemiro
    Castagnet, Mariano
    Xavier, Gleicy L.
    Oliveira, Rene R.
    MATERIALS, 2019, 12 (03)
  • [32] 9 MeV Au ion implantation into Ti and Ti-6Al-4V
    R. Trejo-Luna
    L. R. De La Vega
    J. Rickards
    C. Falcony
    M. Jergel
    Journal of Materials Science, 2001, 36 : 503 - 510
  • [33] 9 MeV au ion implantation into Ti and Ti-6Al-4V
    Trejo-Luna, R
    De la Vega, LR
    Rickards, J
    Falcony, C
    Jergel, M
    JOURNAL OF MATERIALS SCIENCE, 2001, 36 (02) : 503 - 510
  • [34] Ion implantation of the tool's rake face for machining of the Ti-6Al-4V alloy
    Narojczyk, J.
    Morozow, D.
    Narojczyk, J. W.
    Rucki, M.
    JOURNAL OF MANUFACTURING PROCESSES, 2018, 34 : 274 - 280
  • [35] Improving the tribological properties of Ti-6Al-4V alloy by nitrogen-ion implantation
    Itoh, Y
    Itoh, A
    Azuma, H
    Hioki, T
    SURFACE & COATINGS TECHNOLOGY, 1999, 111 (2-3): : 172 - 176
  • [36] Improving the tribological properties of Ti-6Al-4V alloy by nitrogen-ion implantation
    Itoh, Y.
    Itoh, A.
    Azuma, H.
    Hioki, T.
    Surface and Coatings Technology, 1999, 111 (2-3): : 172 - 176
  • [37] Change in Wear Behaviour of Ti and Ti6Al4V after Plasma Immersion Ion Implantation
    Ducherow, Marlen
    Fleischer, Alexander
    Maendl, Stephan
    PLASMA PROCESSES AND POLYMERS, 2007, 4 : S602 - S606
  • [38] THE USE OF ION-IMPLANTATION TO MODIFY THE TRIBOLOGICAL PROPERTIES OF TI-6AL-4V ALLOY
    SARITAS, S
    PROCTER, RPM
    GRANT, WA
    MATERIALS SCIENCE AND ENGINEERING, 1987, 90 : 297 - 306
  • [39] Tribological behavior of different films on Ti-6Al-4V alloy prepared by plasma-based ion implantation
    季红兵
    夏立芳
    马欣新
    孙跃
    TransactionsofNonferrousMetalsSocietyofChina, 2000, (04) : 493 - 497
  • [40] Tribological behavior of different films on Ti-6Al-4V alloy prepared by plasma-based ion implantation
    Ji, HB
    Xia, LF
    Ma, XX
    Sun, Y
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2000, 10 (04) : 493 - 497