Kinetic aspects of hollow fiber liquid-phase microextraction and electromembrane extraction

被引:77
作者
Gjelstad, Astrid [1 ]
Jensen, Henrik [2 ]
Rasmussen, Knut Einar [1 ]
Pedersen-Bjergaard, Stig [1 ,2 ]
机构
[1] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
[2] Univ Copenhagen, Fac Pharmaceut Sci, Dept Pharmaceut & Analyt Chem, DK-2100 Copenhagen, Denmark
关键词
Hollow fiber liquid-phase microextraction; Electromembrane extraction; Supported liquid membrane; Extraction kinetics; Basic drugs; ELECTROKINETIC MIGRATION; SAMPLE PREPARATION; CAPILLARY-ELECTROPHORESIS; BIOLOGICAL-FLUIDS; BASIC DRUGS; MEMBRANE; CHEMISTRY; FIELDS;
D O I
10.1016/j.aca.2011.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor-SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7-8, which was below the pK(a)-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pk(a)-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 21 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Electrokinetic migration of acidic drugs across a supported liquid membrane [J].
Balchen, Marte ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :220-225
[3]   Extraction of lead ions by electromembrane isolation [J].
Basheer, Chanbasha ;
Tan, Shu Hui ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (01) :14-18
[4]   Kinetic electro membrane extraction under stagnant conditions-Fast isolation of drugs from untreated human plasma [J].
Eibak, Lars Erik Eng ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (31) :5050-5056
[5]   Simulation of flux during electro-membrane extraction based on the Nernst-Planck equation [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) :104-111
[6]   Microextraction across supported liquid membranes forced by pH gradients and electrical fields [J].
Gjelstad, Astrid ;
Andersen, Torill Marita ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :38-45
[7]   Electrokinetic migration across artificial liquid membranes - Tuning the membrane chemistry to different types of drug substances [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :29-34
[8]   Electromembrane extraction of basic drugs from untreated human plasma and whole blood under physiological pH conditions [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (03) :921-928
[9]   Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[10]   Low-voltage electromembrane extraction of basic drugs from biological samples [J].
Kjelsen, Inger Johanne Ostegaard ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1180 (1-2) :1-9