Non-invasive microstructural analysis of bowed stringed instruments with synchrotron radiation X-ray microtomography

被引:23
作者
Sodini, Nicola [1 ]
Dreossi, Diego [1 ]
Chen, Rongchang [2 ]
Fioravanti, Marco [3 ]
Giordano, Alberto [4 ]
Herrestal, Peter [5 ]
Rigon, Luigi [2 ]
Zanini, Franco [2 ]
机构
[1] Sincrotrone Trieste SCpA, I-34149 Basovizza Trieste, Italy
[2] Ist Nazl Fis Nucl, Sez Trieste, I-34127 Trieste, Italy
[3] Univ Firenze, DEISTAF, I-50145 Florence, Italy
[4] Alberto Giordano & Co, I-16123 Genoa, Italy
[5] Norwegian State Acad Mus, N-0302 Oslo, Norway
关键词
X-ray microtomography; Local tomography; High resolution; Synchrotron radiation; Wooden musical instruments; TOMOGRAPHY; DAMAGE; CT;
D O I
10.1016/j.culher.2012.04.008
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
The structural analysis of historical musical instruments is a fundamental tool for the definition of restoration and conservation protocols, as well as for the study of ancient manufacturing techniques and the acoustic analysis related to this class of cultural objects. The importance and the value of typical bowed stringed instruments, on the other hand, require a non-destructive approach with strict environmental control, fast acquisition times and high spatial resolution. Feasibility studies have been carried out at the SYRMEP beamline of the Elettra synchrotron laboratory in Trieste with the aim of demonstrating the advantages and evaluating the effectiveness of synchrotron radiation X-ray microtomography as a suitable technique. The particular geometry of the X-ray beam and the use of a novel detector allow structural evaluation of the main details of the instruments with unprecedented richness of details. This, in turn, will allow the characterization of their internal structure, defects, wood thickness and density as well as the dendrochronological investigation of historical violins. (C) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S44 / S49
页数:6
相关论文
共 27 条
[1]   Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA [J].
Abrami, A ;
Arfelli, F ;
Barroso, RC ;
Bergamaschi, A ;
Billé, F ;
Bregant, P ;
Brizzi, F ;
Casarin, K ;
Castelli, E ;
Chenda, V ;
Palma, LD ;
Dreossi, D ;
Fava, A ;
Longo, R ;
Mancini, L ;
Menk, RH ;
Montanari, F ;
Olivo, A ;
Pani, S ;
Pillon, A ;
Quai, E ;
Kaiser, SR ;
Rigon, L ;
Rokvic, T ;
Tonutti, M ;
Tromba, G ;
Vaseotto, A ;
Venanzi, C ;
Zanconati, F ;
Zanetti, A ;
Zanini, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) :221-227
[2]  
Borman T., 2009, J Violin Soc Am: VSA Papers, V22, P1
[3]   Observation of microstructure and damage in materials by phase sensitive radiography and tomography [J].
Cloetens, P ;
PateyronSalome, M ;
Buffiere, JY ;
Peix, G ;
Baruchel, J ;
Peyrin, F ;
Schlenker, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (09) :5878-5886
[4]   Clinical mammography at the SYRMEP beam line: Toward the digital detection system [J].
Dreossi, D. ;
Bergamaschi, A. ;
Schmitt, B. ;
Vallazza, E. ;
Arfelli, F. ;
Longo, R. ;
Menk, R. H. ;
Rigon, L. ;
Rokvic, T. ;
Venanzi, C. ;
Castelli, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) :160-163
[5]  
Dreossi D., 2010, SYNCHROTRON RAD MICR, P34
[6]   Review on the characterisation of ancient stringed musical instruments varnishes and implementation of an analytical strategy [J].
Echard, Jean-Philippe ;
Lavedrine, Bertrand .
JOURNAL OF CULTURAL HERITAGE, 2008, 9 (04) :420-429
[7]   LOCAL TOMOGRAPHY [J].
FARIDANI, A ;
RITMAN, EL ;
SMITH, KT .
SIAM JOURNAL ON APPLIED MATHEMATICS, 1992, 52 (02) :459-484
[8]   Local tomography .2. [J].
Faridani, A ;
Finch, DV ;
Ritman, EL ;
Smith, KT .
SIAM JOURNAL ON APPLIED MATHEMATICS, 1997, 57 (04) :1095-1127
[9]   High-resolution computed tomography from efficient sampling [J].
Faridani, A ;
Ritman, EL .
INVERSE PROBLEMS, 2000, 16 (03) :635-650
[10]  
Gattoni F, 1999, Radiol Med, V97, P170