Image quality degradation by light scattering in display devices

被引:38
作者
Flynn, MJ
Badano, A
机构
[1] Henry Ford Hlth Syst, Dept Diagnost Radiol, Detroit, MI 48202 USA
[2] Univ Michigan, Nucl Engn & Radiol Sci Dept, Ann Arbor, MI 48109 USA
关键词
display; image quality; glare; reflection; contrast;
D O I
10.1007/BF03168843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Veiling glare and ambient light reflection can significantly degrade the quality of an image on a display device. Veiling glare is primarily associated with the diffuse spread of image signal caused by multiple light scattering in the emissive structure of the device. The glare ratio associated with a test image with a 1-cm-diameter black spot is reported as 555 for film, 89 for a monochrome monitor, and 25 for a color monitor. Diffuse light reflection results from ambient light entering the display surface and returning at random emission angles. The diffuse reflection coefficient (luminance/illuminance, 1/sr) is reported as 0.026 for film, 0.058 for a monochrome monitor, and 0.025 for a color monitor with an antireflective surface coating. Both processes increase the luminance in black regions and cause contrast reduction. Specular reflections interfere with detail in the displayed scene. The specular reflection coefficient (luminance/luminance) is reported as 0.011 for film, 0.041 for a monochrome monitor, and 0.021 for a color monitor with an antireflective coating. Copyright (C) 1999 by W.B. Saunders Company.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 32 条
  • [1] *ACR NEMA WORK GRO, 1997, GREYSC DISPL FUNCT S
  • [2] Image degradation by glare in radiologic display devices
    Badano, A
    Flynn, MJ
    [J]. IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 222 - 231
  • [3] Experimental measurements of glare in cathode-ray tubes
    Badano, A
    Flynn, MJ
    [J]. IMAGE DISPLAY - MEDICAL IMAGING 1998, 1998, 3335 : 188 - 196
  • [4] Performance of low-voltage phosphors in emissive flat panel displays for radiologic application
    Badano, A
    Flynn, MJ
    Samei, E
    Kearfott, KG
    [J]. IMAGE DISPLAY: MEDICAL IMAGING 1996, 1996, 2707 : 312 - 321
  • [5] BADANO A, 1997, INT DISPL RES C, P382
  • [6] BADANO A, 1998, P SID, P495
  • [7] Evaluation and characterization of display reflectance
    Becker, ME
    [J]. DISPLAYS, 1998, 19 (01) : 35 - 54
  • [8] INTRAOCULAR LIGHT-SCATTERING IN VISION, ARTISTIC PAINTING, AND PHOTOGRAPHY
    BECKMAN, C
    NILSSON, O
    PAULSSON, LE
    [J]. APPLIED OPTICS, 1994, 33 (21): : 4749 - +
  • [9] Image presentation in digital radiology: Perspectives on the emerging DICOM display function standard and its application
    Blume, H
    Hemminger, BM
    [J]. RADIOGRAPHICS, 1997, 17 (03) : 769 - 777
  • [10] BLUME H, 1992, P SOC INF DISPL, P699