Performance of high-speed dental handpieces - Subjected to simulated clinical use and sterilization

被引:16
作者
Leonard, DL [1 ]
Charlton, DG
机构
[1] USAF, Dent Corps, Washington, DC 20330 USA
[2] USAF, Sch Aerosp Med, AFD, Dent Invest Serv, Brooks AFB, TX 78235 USA
关键词
D O I
10.14219/jada.archive.1999.0400
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. The authors investigated the performance of nine commercially available highspeed air-turbine dental handpieces subjected to 1,000 simulated clinical uses and sterilizations. Methods. Six new handpieces from each of nine different models were subjected to simulated clinical use with a custom-made handpiece wear tester and then autoclaved. Ten parameters related to clinical performance (longevity, power, turbine speed, fiberoptic transmission, eccentricity, noise, chuck performance, visibility angle, interocclusal clearance and water coolant spray pattern) were measured at baseline and after 250, 500, 750 and 1,000 use/sterilization cycles. Results. Power, turbine speed, eccentricity and noise performance were statistically analyzed using one-way analysis of variance and Tukey post hoc pairwise comparison tests at the .05 significance level. At baseline, significant differences were found between models for all of these parameters. In general, from baseline to 1,000 cycles, the handpieces exhibited greater eccentricity and reduced fiberoptic performance. Longevity data analyzed by using Geban's generalized Wilcoxon test for comparison of survival distributions (alpha=.05) revealed significant differences between the handpiece models. Conclusions. The results of this study indicate that no handpiece model is superior to the others in all parameters evaluated. All models evaluated can be expected to perform for at least 500 clinical use/sterilizations, or approximately one year, if properly maintained. Clinical Implications. Clinicians need to be able to identify handpieces that can withstand repeated heat sterilization without loss of performance or longevity. The results of this study will aid clinicians in selecting handpiece models that meet their needs.
引用
收藏
页码:1301 / 1311
页数:11
相关论文
共 20 条
[1]  
Angelini E, 1992, Quintessence Int, V23, P215
[2]  
[Anonymous], 1996, J AM DENT ASSOC, V127, P672
[3]   DYNAMIC MEASUREMENT OF THE TORQUE-SPEED CHARACTERISTICS OF DENTAL HIGH-SPEED AIR TURBINE HANDPIECES [J].
BROCKHURST, PJ ;
SHAMS, R .
AUSTRALIAN DENTAL JOURNAL, 1994, 39 (01) :33-38
[4]  
Childs James E., 1993, Morbidity and Mortality Weekly Report, V42, P1
[5]   THE DEVELOPMENT OF THE DENTAL HIGH-SPEED AIR TURBINE HANDPIECE .2. [J].
DYSON, JE ;
DARVELL, BW .
AUSTRALIAN DENTAL JOURNAL, 1993, 38 (02) :131-143
[6]  
EAMES WB, 1979, OPER DENT, V4, P124
[7]  
FOSTER CD, 1984, 8420 USAF SCH AER ME, P1
[8]  
*INT STAND ORG, 1992, 778511992 INT STAND
[9]   How well does the chemiclave sterilize handpieces? [J].
Kolstad, RA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1998, 129 (07) :985-991
[10]  
KUEHNE JC, 1992, PERFORMANCE DURABILI, P1