Simplification of the kinematic model of human movement

被引:0
作者
Dusza, Jacek J. [1 ]
Wawrzyniak, Zbigniew M. [1 ,2 ]
del Prado Martinez, David [3 ]
机构
[1] Warsaw Univ Technol, ISE, 15-19 Nowowiejska Str, Warsaw, Poland
[2] Med Univ Warsaw, Dept Hlth Sci, NCZ, Warsaw, Poland
[3] Univ Valladolid, Valladolid, Spain
来源
PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2013 | 2013年 / 8903卷
关键词
humane movement; kinematic model; gait analysis; simplification; FFT method; biomedical model; GAIT;
D O I
10.1117/12.2035448
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The paper presents a methods of simplification of the human gait model. The experimental data were obtained in the laboratory of the group SATI in the Electronics Engineering Department of the University of Valencia. As a result of the Mean Double Step (MDS) procedure, the human motion were described by a matrix containing the Cartesian coordinates of 26 markers placed on the human body recorded in the 100 time points. With these data it has been possible to develop an software application which performs a wide diversity of tasks like array simplification, mask calculation for the simplification, error calculation as well as tools for signals comparison and movement animation of the markers. Simplifications were made by the spectral analysis of signals and calculating the standard deviation of the differences between the signal and its approximation. Using this method the signals of displacement could be written as the time series limited to a small number of harmonic signals. This approach allows us for a high degree of data compression. The model presented in this work can be applied into the context of medical diagnostics or rehabilitation because for a given approximation error and a large number of harmonics may demonstrate some abnormalities (of orthopaedic symptoms) in the gait cycle analysis.
引用
收藏
页数:8
相关论文
共 9 条
  • [1] Probabilistic combination of static and dynamic gait features for verification
    Bazin, AI
    Nixon, MS
    [J]. BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION II, 2005, 5779 : 23 - 30
  • [2] Best R., 2006, COMPUTATIONAL INTELL, P11
  • [3] On Using Gait in Forensic Biometrics
    Bouchrika, Imed
    Goffredo, Michaela
    Carter, John
    Nixon, Mark
    [J]. JOURNAL OF FORENSIC SCIENCES, 2011, 56 (04) : 882 - 889
  • [4] Cunado D, 2003, COMPUT VIS IMAGE UND, V90, P1, DOI [10.1016/S1077-3142(03)00008-0, 10.1010/SI077-3142(03)00008-0]
  • [5] Dusza J. J, 2012, P SPIE, V8454
  • [6] Ekinci M., 2006, Turkish Journal Electrical Engineering and Computer Sciences, Elektrik, V14, P267
  • [7] Nixon M.S., 2004, IEEE Face and Gesture Analysis 2004, FG04, P11
  • [8] Poletto P. R., 2007, REV BRAS FISIOTER, V11, P39
  • [9] Performance analysis on new biometric gait motion model
    Yam, CY
    Nixon, MS
    Carter, JN
    [J]. FIFTH IEEE SOUTHWEST SYMPOSIUM ON IMAGE ANALYSIS AND INTERPRETATION, PROCEEDINGS, 2002, : 31 - 34