Cerebral Blood Volume Analysis in Glioblastomas Using Dynamic Susceptibility Contrast-Enhanced Perfusion MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

被引:45
作者
Jung, Seung Chai [1 ]
Choi, Seung Hong [1 ]
Yeom, Jeong A. [1 ]
Kim, Ji-Hoon [1 ]
Ryoo, Inseon [1 ]
Kim, Soo Chin [1 ]
Shin, Hwaseon [1 ]
Lee, A. Leum [1 ]
Yun, Tae Jin [1 ]
Park, Chul-Kee [2 ]
Sohn, Chul-Ho [1 ]
Park, Sung-Hye [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Neurosurg, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Pathol, Seoul 151, South Korea
关键词
BRAIN-TUMOR SEGMENTATION; HISTOGRAM ANALYSIS; INTRAOBSERVER REPRODUCIBILITY; AUTOMATIC SEGMENTATION; HISTOLOGIC-FINDINGS; GLIOMAS; GRADE; MAPS; INTEROBSERVER; IMAGES;
D O I
10.1371/journal.pone.0069323
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas. Materials and Methods: Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility. Results: Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74-0.89 and CV of 20.39-36.83% in manual segmentation method, and ICC of 0.95-0.99 and CV of 8.53-16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86-0.94 and CV of 19.67-35.15% in manual segmentation method, and ICC of 0.74-1.0 and CV of 5.48-49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods. Conclusion: The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.
引用
收藏
页数:9
相关论文
共 33 条
[1]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[2]   Intra- and Interobserver Variability of Linear and Volumetric Measurements of Brain Metastases Using Contrast-Enhanced Magnetic Resonance Imaging [J].
Bauknecht, Hans-Christian ;
Romano, Valentina C. ;
Rogalla, Patrik ;
Klingebiel, Randolf ;
Wolf, Claudia ;
Bornemann, Lars ;
Hamm, Bernd ;
Hein, Patrick A. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (01) :49-56
[3]  
Bjornerud A, 2003, P HUM BRAIN MAPPING, P19
[4]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[5]   Automatic tumor segmentation using knowledge-based techniques [J].
Clark, MC ;
Hall, LO ;
Goldgof, DB ;
Velthuizen, R ;
Murtagh, FR ;
Silbiger, MS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :187-201
[6]   GLIOMAS - CLASSIFICATION WITH MR IMAGING [J].
DEAN, BL ;
DRAYER, BP ;
BIRD, CR ;
FLOM, RA ;
HODAK, JA ;
COONS, SW ;
CAREY, RG .
RADIOLOGY, 1990, 174 (02) :411-415
[7]  
Eldevik OP, 1996, AM J NEURORADIOL, V17, P1427
[8]   Histogram Analysis of MR Imaging-Derived Cerebral Blood Volume Maps: Combined Glioma Grading and Identification of Low-Grade Oligodendroglial Subtypes [J].
Emblem, K. E. ;
Scheie, D. ;
Due-Tonnessen, P. ;
Nedregaard, B. ;
Nome, T. ;
Hald, J. K. ;
Beiske, K. ;
Meling, T. R. ;
Bjornerud, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (09) :1664-1670
[9]   Glioma grading by using histogram analysis of blood volume heterogeneity from MR-derived cerebral blood volume maps [J].
Emblem, Kyrre E. ;
Nedregaard, Baard ;
Nome, Terje ;
Due-Tonnessen, Paulina ;
Hald, John K. ;
Scheie, David ;
Borota, Olivera Casar ;
Cvancarova, Milada ;
Bjornerud, Atle .
RADIOLOGY, 2008, 247 (03) :808-817
[10]   Automatic Glioma Characterization from Dynamic Susceptibility Contrast Imaging: Brain Tumor Segmentation Using Knowledge-Based Fuzzy Clustering [J].
Emblem, Kyrre E. ;
Nedregaard, Baard ;
Hald, John K. ;
Nome, Terje ;
Due-Tonnessen, Paulina ;
Bjornerud, Atle .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) :1-10