Axisymmetrical free-vibration analysis of liquid-storage tanks considering the liquid compressibility

被引:2
|
作者
Cho, JR [1 ]
Lee, JK [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Pusan 609735, South Korea
关键词
axisymmetrical free vibration; liquid compressibility; acoustic wave; coupled liquid-structure formulation; relative difference; parametric variation;
D O I
10.12989/sem.2002.13.4.355
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, we address the numerical investigation on the effect of liquid compressibility onto the natural frequency of liquid-filled containers. Traditionally the liquid motion has been treated as an ideal fluid motion. However, from the numerical experiments for the axisymmetrical free-vibration of cylindrical liquid-storage tanks, we found that the relative difference in natural frequencies between ideal and compressible motions becomes remarkable, as the slenderness of tank or the relative liquid-fill height becomes larger. Therefore, in such cases of dynamic systems, the liquid compressibility becomes an important parameter, for the accurate vibration analysis. For the free-vibration analysis of compressible liquid-structure interaction we employed the coupled finite element formulation expressed in terms of the acoustic wave pressure and the structure deformation.
引用
收藏
页码:355 / 368
页数:14
相关论文
共 50 条
  • [21] EXPERIMENT MODAL ANALYSIS OF LIQUID-STRUCTURE INTERACTION ON STEELINESS RECTANGULAR LIQUID-STORAGE TANKS
    Cheng, Xuan-Sheng
    Shi, Xiao-Yu
    Zhang, Gui-Wen
    Du, Yong-Feng
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1119 - 1123
  • [22] COMPLICATIONS IN FREE-VIBRATION ANALYSIS OF TANKS
    HAROUN, MA
    HOUSNER, GW
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1982, 108 (05): : 801 - 818
  • [23] Sloshing loads in liquid-storage tanks with insufficient freeboard
    Malhotra, PK
    EARTHQUAKE SPECTRA, 2005, 21 (04) : 1185 - 1192
  • [24] Method for seismic base isolation of liquid-storage tanks
    Malhotra, PK
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (01): : 113 - 116
  • [25] AXISYMMETRICAL FREE-VIBRATION ANALYSIS OF CONICAL SHELLS
    THAMBIRATNAM, DP
    YAN, ZG
    ENGINEERING STRUCTURES, 1993, 15 (02) : 83 - 89
  • [26] New method for seismic isolation of liquid-storage tanks
    Dept of Civil Engineering, California State Univ, Adjunct Faculty, Sacramento, CA 95819-6029, United States
    Earthquake Engineering and Structural Dynamics, 1997, 26 (08): : 839 - 847
  • [27] New method for seismic isolation of liquid-storage tanks
    Malhotra, PK
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1997, 26 (08): : 839 - 847
  • [28] DYNAMIC INTERACTION BETWEEN LIQUID-STORAGE TANKS AND SUBSOIL
    LATZ, K
    ANTES, H
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1994, 74 (04): : T131 - T133
  • [29] Fragility curves for baffled concrete cylindrical liquid-storage tanks
    Hajimehrabi, Hossein
    Behnamfar, Farhad
    Samani, Abdorreza Kabiri
    Goudarzi, Mohammad Ali
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 119 : 187 - 195
  • [30] FREE-VIBRATION ANALYSIS OF CANTILEVER CYLINDRICAL TANKS
    HADID, HA
    HASSON, DA
    STRUCTURAL ENGINEERING AND MECHANICS, 1995, 3 (01) : 25 - 34