Hypo-Attenuated Leaflet Thickening and Reduced Leaflet Motion in Sutureless Bioprosthetic Aortic Valves

被引:25
作者
Dalen, Magnus [1 ,3 ]
Sartipy, Ulrik [1 ,3 ]
Cederlund, Kerstin [2 ,4 ]
Franco-Cereceda, Anders [1 ,3 ]
Svensson, Anders [2 ,4 ]
Themudo, Raquel [2 ,5 ]
Svenarud, Peter [1 ,3 ]
Brolin, Elin Bacsovics [2 ,4 ]
机构
[1] Karolinska Univ Hosp, Dept Cardiothorac Surg & Anesthesiol, SE-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Radiol Huddinge, Stockholm, Sweden
[3] Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden
[4] Karolinska Inst, Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[5] Karolinska Inst, Dept Clin Physiol, Stockholm, Sweden
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2017年 / 6卷 / 08期
关键词
aortic valve surgery; bioprosthesis; cardiac computed tomography; leaflet motion; leaflet thickening; THROMBOSIS;
D O I
10.1161/JAHA.116.005251
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The prevalence of hypo-attenuated leaflet thickening (HALT) and reduced leaflet motion (RLM) is unknown in surgically implanted bioprostheses because systematic investigation of HALT and/or RLM is limited to a few catheter-based valves. The aim of this study was to investigate the prevalence of HALT and RLM by cardiac computed tomography in patients who underwent surgical aortic valve replacement and received a Perceval sutureless aortic valve bioprosthesis. Methods and Results-This was a single-center prospective observational study that included 47 patients (83.5% of the total number of implantations) who underwent surgical aortic valve replacement with implantation of the Perceval sutureless bioprosthesis (LivaNova PLC, London, UK) at Karolinska University Hospital in Stockholm, Sweden from 2012 to 2016 and were studied by cardiac computed tomography. Cardiac computed tomography was performed at a median of 491 days (range 361247 days) postoperatively. HALT was found in 18 (38%) patients and RLM in 13 (28%) patients. All patients with RLM had HALT. Among patients with HALT, 5 out of 18 patients (28%) were treated with anticoagulation (warfarin or any novel oral anticoagulant) at the time of cardiac computed tomography. Among patients with RLM, 3 out of 13 patients (23%) were treated with anticoagulation. Conclusions-HALT and RLM were prevalent in the surgically implanted Perceval sutureless aortic valve bioprosthesis. Both HALT and RLM were found in patients with ongoing anticoagulation treatment. Whether these findings are associated with adverse events needs further study.
引用
收藏
页数:22
相关论文
共 19 条
[1]   Embolization from biological prosthetic aortic root [J].
Anselmino, Monica ;
Andria, Anna .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (03) :228-229
[2]  
Budoff MJ, 2005, CIRCULATION, V112, P598, DOI [10.1016/j.jacc.2005.04.033, 10.1161/CIRCULATIONAHA.105.168237]
[3]   Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study [J].
Chakravarty, Tarun ;
Sondergaard, Lars ;
Friedman, John ;
De Backer, Ole ;
Berman, Daniel ;
Kofoed, Klaus F. ;
Jilaihawi, Hasan ;
Shiota, Takahiro ;
Abramowitz, Yigal ;
Jorgensen, Troels H. ;
Rami, Tanya ;
Israr, Sharjeel ;
Fontana, Gregory ;
de Knegt, Martina ;
Fuchs, Andreas ;
Lyden, Patrick ;
Trento, Alfredo ;
Bhatt, Deepak L. ;
Leon, Martin B. ;
Makkar, Raj R. .
LANCET, 2017, 389 (10087) :2383-2392
[4]   The sutureless aortic valve at 1 year: A large multicenter cohort study [J].
Fischlein, Theodor ;
Meuris, Bart ;
Hakim-Meibodi, Kavous ;
Misfeld, Martin ;
Carrel, Thierry ;
Zembala, Marian ;
Gaggianesi, Sara ;
Madonna, Francesco ;
Laborde, Francois ;
Asch, Federico ;
Haverich, Axel .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (06) :1617-+
[5]   Transcatheter Aortic Valve Thrombosis Incidence, Predisposing Factors, and Clinical Implications [J].
Hansson, Nicolaj C. ;
Grove, Erik L. ;
Andersen, Henning R. ;
Leipsic, Jonathon ;
Mathiassen, Ole N. ;
Jensen, Jesper M. ;
Jensen, Kaare T. ;
Blanke, Philipp ;
Leetmaa, Tina ;
Tang, Mariann ;
Krusell, Lars R. ;
Klaaborg, Kaj E. ;
Christiansen, Evald H. ;
Terp, Kim ;
Terkelsen, Christian J. ;
Poulsen, Steen H. ;
Webb, John ;
Botker, Hans Erik ;
Norgaard, Bjarne L. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (19) :2059-2069
[6]  
Harold JG, 2014, J AM COLL CARDIOL, V63, pE57, DOI [10.1016/j.jacc.2014.02.537, 10.1016/j.jacc.2014.02.536, 10.1016/j.jtcvs.2014.05.014]
[7]   The various states of von Willebrand factor and their function in physiology and pathophysiology [J].
Huck, Volker ;
Schneider, Matthias F. ;
Gorzelanny, Christian ;
Schneider, Stefan W. .
THROMBOSIS AND HAEMOSTASIS, 2014, 111 (04) :598-609
[8]   Reduced Leaflet Motion in Bioprosthetic Aortic Valves - The FDA Perspective [J].
Laschinger, John C. ;
Wu, Changfu ;
Ibrahim, Nicole G. ;
Shuren, Jeffrey E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (21) :1996-1998
[9]   Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography [J].
Leetmaa, Tina ;
Hansson, Nicolaj C. ;
Leipsic, Jonathon ;
Jensen, Kaare ;
Poulsen, Steen H. ;
Andersen, Henning R. ;
Jensen, Jesper M. ;
Webb, John ;
Blanke, Philipp ;
Tang, Mariann ;
Norgaard, Bjarne L. .
Circulation-Cardiovascular Interventions, 2015, 8 (04)
[10]   Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves [J].
Makkar, R. R. ;
Fontana, G. ;
Jilaihawi, H. ;
Chakravarty, T. ;
Kofoed, K. F. ;
de Backer, O. ;
Asch, F. M. ;
Ruiz, C. E. ;
Olsen, N. T. ;
Trento, A. ;
Friedman, J. ;
Berman, D. ;
Cheng, W. ;
Kashif, M. ;
Jelnin, V. ;
Kliger, C. A. ;
Guo, H. ;
Pichard, A. D. ;
Weissman, N. J. ;
Kapadia, S. ;
Manasse, E. ;
Bhatt, D. L. ;
Leon, M. B. ;
Sondergaard, L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (21) :2015-2024