Detection of Optic Nerve Head Neural Canal Opening within Histomorphometric and Spectral Domain Optical Coherence Tomography Data Sets

被引:89
|
作者
Strouthidis, Nicholas G. [1 ]
Yang, Hongli [1 ,4 ]
Fortune, Brad [2 ]
Downs, J. Crawford [3 ]
Burgoyne, Claude F. [1 ]
机构
[1] Devers Eye Inst, Opt Nerve Head Res Lab, Portland, OR 97208 USA
[2] Devers Eye Inst, Electrodiagnost Serv, Portland, OR 97208 USA
[3] Devers Eye Inst, Ocular Biomech Lab, Portland, OR 97208 USA
[4] Tulane Univ, Dept Biomed Engn, New Orleans, LA 70118 USA
关键词
HEIDELBERG RETINA TOMOGRAPH; SCANNING LASER OPHTHALMOSCOPY; ELEVATED INTRAOCULAR-PRESSURE; LATERAL GENICULATE-NUCLEUS; GANGLION-CELL DEATH; OPEN-ANGLE GLAUCOMA; REFERENCE PLANE; PARVOCELLULAR LAYERS; 3-D HISTOMORPHOMETRY; LAMINA-CRIBROSA;
D O I
10.1167/iovs.08-2302
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the ability to detect the neural canal opening (NCO) and its characteristics within three-dimensional (3-D) histomorphometric and 3-D spectral domain optical coherence tomography (SD-OCT) reconstructions of the optic nerve head from nonhuman primate (NHP) eyes. METHODS. NCO was delineated within 40 radial, sagittal sections of 3-D histomorphometric reconstructions of 44 normal eyes of 38 NHPs, each perfusion fixed at IOP 10 mm Hg, and 3-D SD-OCT (Spectralis; Heidelberg Engineering, Heidelberg, Germany) volumes acquired in vivo from a separate group of 33 normal eyes of 24 NHPs. Within all reconstructions, a least-squares ellipse was fitted to the 80 NCO points. For each eye, the dimensions and plane error (a gauge of planarity) of the fitted ellipse were calculated. RESULTS. The NCO was successfully delineated within every section of each histomorphometric and SD-OCT reconstruction. Median plane error was similar within histomorphometric and SD-OCT volumes (8 mu m, range 4-19, histomorphometry, and 10 mu m, range 4 - 26, SD-OCT) and was small relative to the size of the ellipse. Median histomorphometric ellipse dimensions were 1453 mu m (major axis, range 1218-1737) and 1066 mu m (minor axis, range 808-1263). Median SD-OCT ellipse dimensions were 1512 mu m (major axis, range 1191-1865) and 1060 mu m (minor axis, range 772-1248). CONCLUSIONS. The NCO is biologically continuous and relatively planar within all 3-D histomorphometric and SD-OCT reconstructions. These characteristics support its further evaluation as a reference plane for cross-sectional and longitudinal measurement of optic nerve head structures using 3-D SD-OCT. (Invest Ophthalmol Vis Sci. 2009; 50: 214-223) DOI: 10.1167/iovs.08-2302
引用
收藏
页码:214 / 223
页数:10
相关论文
共 50 条
  • [31] Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography
    Li, Songfeng
    Wang, Xiaozhen
    Li, Shuning
    Wu, Gewei
    Wang, Ningli
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (03) : 429 - 434
  • [32] In vivo characterization of the deformation of the human optic nerve head using optical coherence tomography and digital volume correlation
    Midgett, Dan E.
    Quigley, Harry A.
    Nguyen, Thao D.
    ACTA BIOMATERIALIA, 2019, 96 : 385 - 399
  • [33] Evaluation of Automated Segmentation Algorithms for Optic Nerve Head Structures in Optical Coherence Tomography Images
    Duan, Xiangyun J.
    Jefferys, Joan L.
    Quigley, Harry A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (10) : 3816 - 3826
  • [34] Evaluation of macular and optic nerve head parameters in amblyopic eyes: An optical coherence tomography study
    Guagliano, Rosanna
    Barilla, Donatella
    Bertone, Chiara
    Montescani, Silvia
    Verticchio Vercellin, Alice C.
    Arpa, Cristina
    Tinelli, Carmine
    De Angelis, Giovanni
    Quaranta, Luciano
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (04) : 1991 - 1996
  • [35] Optical coherence tomography evaluation of the optic nerve head neuro-retinal rim in glaucoma
    Fortune, Brad
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (03) : 286 - 290
  • [36] Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography
    Chen, Chieh-Li
    Bojikian, Karine D.
    Xin, Chen
    Wen, Joanne C.
    Gupta, Divakar
    Zhang, Qinqin
    Mudumbai, Raghu C.
    Johnstone, Murray A.
    Chen, Philip P.
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [37] Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve Head
    Girard, Michael J. A.
    Strouthidis, Nicholas G.
    Ethier, C. Ross
    Mari, Jean Martial
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7738 - 7748
  • [38] Vascular density of optic nerve head in diabetic retinopathy using optical coherence tomography angiography
    Ghassemi, Fariba
    Berijani, Sahar
    Roohipoor, Ramak
    Mohebbi, Masoumeh
    Babeli, Ameneh
    Gholizadeh, Alireza
    Sabour, Siamak
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2020, 6 (01)
  • [39] Evaluation of macular and optic nerve head changes by optical coherence tomography angiography in glaucomatous eyes
    Mohamed, Ezzeldin G.
    Elsersy, Tamer H.
    Lotfy, Ayman M.
    Elshabrawy, Ahmed M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (04) : 292 - 305
  • [40] Optic Disc Vascularization in Glaucoma: Value of Spectral-Domain Optical Coherence Tomography Angiography
    Leveque, Pierre-Maxime
    Zeboulon, Pierre
    Brasnu, Emmanuelle
    Baudouin, Christophe
    Labbe, Antoine
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016