The preliminary evaluation of a 1 MHz ultrasound probe for measuring the elastic anisotropy of human cortical bone

被引:17
作者
Daugschies, M. [1 ]
Rohde, K. [1 ]
Glueer, C. -C. [1 ]
Barkmann, R. [1 ]
机构
[1] Univ Klinikum Schleswig Holstein, Radiol Klin, Sekt Biomed Bildgebung, D-24118 Kiel, Germany
关键词
Sound velocity; Elastic anisotropy; Tibia; Quantitative ultrasound; Ultrasound array; QUANTITATIVE ULTRASOUND; FRACTURE DISCRIMINATION; VELOCITY; OSTEOPOROSIS; PRECISION; POROSITY; TISSUE;
D O I
10.1016/j.ultras.2013.07.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Our objective is to evaluate an ultrasound probe for measurements of velocity and anisotropy in human cortical bone (tibia). The anisotropy of cortical bone is a known and mechanically relevant property in the context of osteoporotic fracture risk. Current in vivo quantitative ultrasound devices measuring the velocity of ultrasound in long bones can only be applied in the axial direction. For anisotropy measurements a second direction for velocity measurements preferably perpendicular to the axial direction is necessary. We developed a new ultrasound probe which permits axial transmission measurements with a simultaneous second perpendicular direction (tangential). Anisotropy measurements were performed on isotropic and anisotropic phantoms and two excised human female tibiae (age 63 and 82). Anisotropy ratios (AI; ratio of squared ultrasound velocities in the two directions) were for the isotropic phantom 1.06 +/- 0.01 and for the anisotropic phantom 1.14 +/- 0.03 (mean +/- standard deviation). AI was 1.83 +/- 0.29 in the tibia from the older donor and 1.37 +/- 0.18 in the tibia from the younger donor. The AIs were in the expected range and differed significantly (p < 0.05, t-test) between the tibiae. Measured sound velocities were reproducible (mean standard deviation of short time precision of both channels for phantom measurements 31 m/s) and in agreement with reported velocities of the phantom material. Our results document the feasibility of anisotropy measurements at long bones using a single probe. Further improvements in the design of the probe and tests in vivo are warranted. If this approach can be evaluated in vivo an additional tool for assessing the bone status is available for clinical use. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:4 / 10
页数:7
相关论文
共 19 条
[1]  
[Anonymous], ULTRASONICS
[2]   A new method for quantitative ultrasound measurements at multiple skeletal sites -: First Results of precision and fracture discrimination [J].
Barkmann, R ;
Kantorovich, E ;
Singal, C ;
Hans, D ;
Genant, HK ;
Heller, M ;
Glüer, CC .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) :1-7
[3]   Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models [J].
Bossy, E ;
Talmant, M ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (05) :2314-2324
[4]   Elastic anisotropy and off-axis ultrasonic velocity distribution in human cortical bone [J].
Chung, Dong Hwa ;
Dechow, Paul C. .
JOURNAL OF ANATOMY, 2011, 218 (01) :26-39
[5]   Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample:: the OPUS study [J].
Glüer, CC ;
Eastell, R ;
Reid, DM ;
Felsenberg, D ;
Roux, C ;
Barkmann, R ;
Timm, W ;
Blenk, T ;
Armbrecht, G ;
Stewart, A ;
Clowes, J ;
Thomasius, FE ;
Kolta, S .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (05) :782-793
[6]   A two-parameter model of the effective elastic tensor for cortical bone [J].
Grimal, Quentin ;
Rus, Guillermo ;
Parnell, William J. ;
Laugier, Pascal .
JOURNAL OF BIOMECHANICS, 2011, 44 (08) :1621-1625
[7]   Relative contributions of porosity and mineralized matrix properties to the bulk axial ultrasonic wave velocity in human cortical bone [J].
Grondin, Julien ;
Grimal, Quentin ;
Yamamoto, Kazufumi ;
Matsukawa, Mami ;
Saied, Amena ;
Laugier, Pascal .
ULTRASONICS, 2012, 52 (04) :467-471
[8]   Hip Fractures and the Contribution of Cortical Versus Trabecular Bone to Femoral Neck Strength [J].
Holzer, Gerold ;
von Skrbensky, Gobert ;
Holzer, Lukas A. ;
Pichl, Wolfgang .
JOURNAL OF BONE AND MINERAL RESEARCH, 2009, 24 (03) :468-474
[9]   THE STRUCTURE AND ANISOTROPIC MECHANICAL-PROPERTIES OF BONE [J].
KATZ, JL ;
YOON, HS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (12) :878-884
[10]   Can the WHO definition of osteoporosis be applied to multi-site axial transmission quantitative ultrasound? [J].
Knapp, KM ;
Blake, GM ;
Spector, TD ;
Fogelman, I .
OSTEOPOROSIS INTERNATIONAL, 2004, 15 (05) :367-374