Study of iodine removal efficiency in self-priming venturi scrubber

被引:22
作者
Ali, Majid [1 ]
Yan, Changqi [1 ]
Sun, Zhongning [1 ]
Gu, Haifeng [1 ]
Wang, Junlong [1 ]
机构
[1] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin, Peoples R China
关键词
Filtered vented containment system; Self-priming venturi scrubber; Iodine; Removal efficiency; Mass transfer; MASS-TRANSFER;
D O I
10.1016/j.anucene.2013.02.014
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Venturi scrubber is used in filtered vented containment system of nuclear power plants to remove the gaseous pollutants from contaminated gas during severe accidents. In this research, an experimental and theoretical investigation has been carried out to study the iodine removal efficiency in a self-priming venturi scrubber. The aqueous solution is prepared by adding weight percentage of sodium hydroxide 0.5% and sodium thiosulphate 0.2% in scrubbing water to increase the absorbance of inorganic iodine (I-2) from the contaminated gas during emission. The iodine removal efficiency is investigated at various gas and liquid flow rates, and iodine inlet concentrations. The iodine removal efficiency is measured experimentally by measuring the inlet and outlet concentration of iodine at sampling ports. The petite droplets are formed in a venturi scrubber to absorb the iodine through the mass transfer phenomenon. A mathematical model for mass transfer based on a gas liquid interface is employed for the verification of experimental results. The contact time between iodine and scrubbing solution depends on the total volumetric flow of gas and liquid, and volume of throat and diffuser of the venturi scrubber. Sauter mean diameter is calculated from the Nukiyama and Tanasawa correlation. Steinberger and Treybal's correlation is used to measure the mass transfer coefficient for the gas phase. The results calculated from the model under predict the experimental data. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 16 条
[1]   Dust particle removal efficiency of a venturi scrubber [J].
Ali, Majid ;
Yan, Changqi ;
Sun, Zhongning ;
Gu, Haifeng ;
Mehboob, Khurram .
ANNALS OF NUCLEAR ENERGY, 2013, 54 :178-183
[2]  
AREVA Inc, 2011, FILT CONT VENT SYST
[3]  
Cheremisinoff N. P., 1977, AIR POLLUTION CONTRO, V2
[4]   Gas pollutants removal in a single- and two-stage ejector-venturi scrubber [J].
Gamisans, X ;
Sarrà, M ;
Lafuente, FJ .
JOURNAL OF HAZARDOUS MATERIALS, 2002, 90 (03) :251-266
[5]   The role of the liquid film on the mass transfer in venturi-based scrubbers [J].
Gamisans, X ;
Sarrà, M ;
Lafuente, FJ .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2004, 82 (A3) :372-380
[6]   BEHAVIOR OF VENTURI SCRUBBERS AS CHEMICAL REACTORS [J].
HILLS, JH .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1995, 34 (12) :4254-4259
[7]  
Kernkraftwerk Gosgen-Daniken AG, 1999, GOSG NUCL POW PLANT
[8]   Aerosol separation efficiency of a venturi scrubber working in self-priming mode [J].
Lehner, M .
AEROSOL SCIENCE AND TECHNOLOGY, 1998, 28 (05) :389-402
[9]  
Mariana, 2004, KOREAN J CHEM ENG, V21, P589
[10]  
Nukiyama S., 1938, T SOC MECH ENG TOKYO, V4, P86