The Incidence of Root Microcracks Caused by 3 Different Single-file Systems versus the ProTaper System

被引:129
作者
Liu, Rui [1 ]
Hou, Ben Xiang [1 ]
Wesselink, Paul R. [2 ,3 ]
Wu, Min-Kai [2 ,3 ]
Shemesh, Hagay [2 ,3 ]
机构
[1] Capital Med Univ, Sch Stomatol, Dept Endodont, Beijing, Peoples R China
[2] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Endodontol, NL-1081 LA Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, NL-1081 LA Amsterdam, Netherlands
关键词
Root crack; single-file system; SELF-ADJUSTING FILE; CANAL PREPARATION; RECIPROCATING MOVEMENT; DENTINAL DEFECTS; INSTRUMENTATION; LENGTH; CRACKS; LIFE;
D O I
10.1016/j.joen.2013.04.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the incidence of root cracks observed at the apical root surface and/or in the canal wall after canal instrumentation with 3 single-file systems and the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland). Methods: One hundred mandibular incisors were selected. Twenty control teeth were coronally flared with Gates-Glidden drills (Dentsply Maillefer). No further preparation was made. The other 80 teeth were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. They were divided into 4 experimental groups (n = 20); the root canals were first coronally flared with Gates-Glidden drills and then instrumented to the full working length with the ProTaper, OneShape (Micro-Mega, Besancon, France), Reciproc (VDW, Munich, Germany), or the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel). The apical root surface and horizontal sections 2, 4, and 6 mm from the apex were observed under a microscope. The presence of cracks was noted. The chi-square test was performed to compare the appearance of cracked roots between the experimental groups. Results: No cracks were found in the control teeth and teeth instrumented with the Self-Adjusting File. Cracks were found in 10 of 20 (50%), 7 of 20 (35%), and 1 of 20 (5%) teeth after canal instrumentation with the ProTaper, OneShape, and Reciproc files, respectively. The difference between the experimental groups was statistically significant (P<.001). Conclusions: Nickel-titanium instruments may cause cracks on the apical root surface or in the canal wall; the Self-Adjusting File and Reciproc files caused less cracks than the ProTaper and OneShape files.
引用
收藏
页码:1054 / 1056
页数:3
相关论文
共 22 条
[1]   The effect of working length and root canal preparation technique on crack development in the apical root canal wall [J].
Adorno, C. G. ;
Yoshioka, T. ;
Suda, H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) :321-327
[2]   Crack Initiation on the Apical Root Surface Caused by Three Different Nickel-Titanium Rotary Files at Different Working Lengths [J].
Adorno, Carlos G. ;
Yoshioka, Takatomo ;
Suda, Hideaki .
JOURNAL OF ENDODONTICS, 2011, 37 (04) :522-525
[3]   The Effect of Root Preparation Technique and Instrumentation Length on the Development of Apical Root Cracks [J].
Adorno, Carlos G. ;
Yoshioka, Takatomo ;
Suda, Hideaki .
JOURNAL OF ENDODONTICS, 2009, 35 (03) :389-392
[4]   Analysis of forces developed during root canal preparation with the balanced force technique [J].
Blum, JY ;
Machtou, P ;
Esber, S ;
Micallef, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (06) :386-396
[5]   Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement [J].
De-Deus, G. ;
Moreira, E. J. L. ;
Lopes, H. P. ;
Elias, C. N. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (12) :1063-1068
[6]   Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement [J].
De-Deus, Gustavo ;
Brandao, Maria Claudia ;
Barino, Bianca ;
Di Giorgi, Karina ;
Sergio Fidel, Rivail Antonio ;
Luna, Aderval Severino .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (03) :390-394
[7]   Investigation on the Shaping Ability of Nickel-Titanium Files When Used with a Reciprocating Motion [J].
Franco, Vittorio ;
Fabiani, Cristiano ;
Taschieri, Silvio ;
Malentacca, Augusto ;
Bortolin, Monica ;
Del Fabbro, Massimo .
JOURNAL OF ENDODONTICS, 2011, 37 (10) :1398-1401
[8]  
Hin ES, 2003, J ENDODONT, V39, P262
[9]   The Self-adjusting File (SAF). Part 2: Mechanical Analysis [J].
Hof, Rafael ;
Perevalov, Valery ;
Eltanani, Moshe ;
Zary, Raviv ;
Metzger, Zvi .
JOURNAL OF ENDODONTICS, 2010, 36 (04) :691-696
[10]   Incidence of Apical Root Cracks and Apical Dentinal Detachments after Canal Preparation with Hand and Rotary Files at Different Instrumentation Lengths [J].
Liu, Rui ;
Kaiwar, Anjali ;
Shemesh, Hagay ;
Wesselink, Paul R. ;
Hou, Benxiang ;
Wu, Min-Kai .
JOURNAL OF ENDODONTICS, 2013, 39 (01) :129-132