Detection of E-coli O157:H7 using a miniaturized surface plasmon resonance biosensor

被引:0
|
作者
Meeusen, CA
Alocilja, EC
Osburn, WN
机构
[1] Michigan State Univ, Dept Agr & Biosyst Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Anim Sci, E Lansing, MI 48824 USA
[3] Walt Disney World Co, Epcot Sci, Lake Buena Vista, FL USA
来源
TRANSACTIONS OF THE ASAE | 2005年 / 48卷 / 06期
关键词
biosensors; E. coli O157 : H7; foodborne pathogens; food safety; surface plasmon resonance (SPR);
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A commercially available Spreeta sensor was adapted into a surface plasmon resonance (SPR) biosensor to detect Escherichia coli O157:H7. The SPR biosensor couples antibody-antigen reactions with signal generation, using Kretschmann geometry to couple light into surface plasmons. The objectives of this study were to test the feasibility of adapting a miniaturized integrated SPR liquid sensing system into a biosensor to detect E. coli O157:H7 in laboratory cultures and to test its sensitivity and specificity. Experiments were conducted at near real-time with results obtained for one SPR biosensor assay within 35 min. The limit of detection for E. coli O157:H7 was determined to be 8.7 X 10(6) CFU/mL. In mixed cultures, the detection limit of the biosensor was 107 CFU/mL for E. coli O157:117 when the non-target bacterial concentration was 10(6) CFU/mL or less. Concentrations of non-target bacteria beyond 10(7) CFU/mL caused a decrease in the magnitude of the sensor response. The results of this study demonstrate the potential for employing the SPR biosensor to detect E. coli O157:H7 in near real-time. The SPR biosensor shows potential as a tool to assist the food industry in pathogen monitoring that is quick and specific. Due to its portability, it can potentially be incorporated into a HACCP protocol in the food industry.
引用
收藏
页码:2409 / 2416
页数:8
相关论文
共 50 条
  • [31] An overview of methods for identification of E-coli O157:H7
    Tortorello, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 16 - AGFD
  • [32] Surface plasmon resonance and quartz crystal microbalance immunosensors for detection of Escherichia coli O157:H7
    Su, XL
    Li, Y
    TRANSACTIONS OF THE ASAE, 2005, 48 (01): : 405 - 413
  • [33] A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E-coli O157:H7
    Subramanian, A
    Irudayaraj, J
    Ryan, T
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 998 - 1006
  • [34] Detection of E-coli O157:H7 DNA by a Novel QCM Biosensor coupled with Gold Nanoparticles Amplification
    Wang, Lijiang
    Wei, Qingshan
    Wu, Chunsheng
    Ji, Jian
    Liu, Qingjun
    Yang, Mo
    Wang, Ping
    2007 7TH IEEE CONFERENCE ON NANOTECHNOLOGY, VOL 1-3, 2007, : 330 - +
  • [35] An anti E-coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E-coli)
    Zhang, J
    Ji, HF
    ANALYTICAL SCIENCES, 2004, 20 (04) : 585 - 587
  • [36] Impedance based detection of pathogenic E-coli O157:H7 using a ferrocene-antimicrobial peptide modified biosensor
    Li, Yongxin
    Afrasiabi, Rouzbeh
    Fathi, Farkhondeh
    Wang, Nan
    Xiang, Cuili
    Love, Ryan
    She, Zhe
    Kraatz, Heinz-Bernhard
    BIOSENSORS & BIOELECTRONICS, 2014, 58 : 193 - 199
  • [37] A net fishing enrichment strategy for colorimetric detection of E-coli O157:H7
    Ren, Wen
    Liu, Wenjie
    Irudayaraj, Joseph
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 923 - 929
  • [38] Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection
    Muhammad-Tahir, Z
    Alocilja, EC
    IEEE SENSORS JOURNAL, 2003, 3 (04) : 345 - 351
  • [39] Research suggests strategy for curbing E-coli O157:H7
    不详
    ASM NEWS, 1998, 64 (11): : 619 - 619
  • [40] Binding interactions of collagen I, laminin and fibronectin with immobilized Escherichia coli O157:H7 using a surface plasmon resonance biosensor
    Medina, MB
    Fratamico, PM
    BIOTECHNOLOGY TECHNIQUES, 1998, 12 (03) : 235 - 240