Test for arsenic speciation in waters based on a paper-based analytical device with scanometric detection

被引:49
|
作者
Pena-Pereira, Francisco [1 ]
Villar-Blanco, Lorena [1 ]
Lavilla, Isela [1 ]
Bendicho, Carlos [1 ]
机构
[1] Univ Vigo, Fac Chem, Analyt & Food Chem Dept, Campus As Lagoas Marcosende S-N, Vigo 36310, Spain
关键词
Paper-based analytical device; Arsenic speciation; Non-instrumental detection; Scanometric analysis; Water analysis; Screening; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; MICROFLUIDIC DEVICES; HYDRIDE GENERATION; CELLULOSE FIBERS; ANALYTICAL-CHEMISTRY; AQUEOUS SAMPLES; DRINKING-WATER; PRECONCENTRATION; NANOPARTICLES;
D O I
10.1016/j.aca.2018.01.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, simple and affordable method for arsenic speciation analysis is described in this work. The proposed methodology involves in situ arsine generation, transfer of the volatile to the headspace and its reaction with silver nitrate at the detection zone of a paper-based analytical device (PAD). Thus, silver nitrate acts as a recognition element for arsine in the paper-based sensor. The chemical reaction between the recognition element and the analyte derivative results in the formation of a colored product which can be detected by scanning the detection zone and data treatment with an image processing and analysis program. Detection and injection zones were defined in the paper substrate by formation of hydrophobic barriers, thus enabling the formation of the volatile derivative without affecting the chemical stability of the recognition element present in the PAD. Experimental parameters influencing the analytical performance of the methodology, namely color mode detection, composition of the paper-based sensor and hydride generation and mass transfer conditions, were evaluated. Under optimal conditions, the proposed method showed limits of detection and quantification of 1.1 and 3.6 ng mL(-1), respectively. Remarkably, the limit of detection of the method reported herein was much lower than the maximum contaminant levels set by both the World Health Organization and the US Environmental Protection Agency for arsenic in drinking water, unlike several commercially available arsenic test kits. The repeatability, expressed as relative standard deviation, was found to be 7.1% (n = 8). The method was validated against the European Reference Material ERM (R)-CA615 groundwater and successfully applied to the determination of As(III), As(V) and total inorganic As in different water samples. Furthermore, the method can be used for the screening analysis of total arsenic in waters when a cut-off level of 7 ng mL(-1) is used. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Simultaneous colorimetric detection of nephrolithiasis biomarkers using a microfluidic paper-based analytical device
    Janrod, Manassawee
    Srisa-Art, Monpichar
    ANALYTICAL METHODS, 2023, 15 (06) : 752 - 761
  • [22] Novel field amplification for sensitive colorimetric detection of microalbuminuria on a paper-based analytical device
    Cai, Yu
    Niu, Ji-Cheng
    Du, Xin-Li
    Fang, Fang
    Wu, Zhi-Yong
    ANALYTICA CHIMICA ACTA, 2019, 1080 : 146 - 152
  • [23] Naked-Eye Detection of Aluminum in Gastric Drugs on a Paper-Based Analytical Device
    Lai, Heyun
    Li, Ziqi
    Zhu, Shunying
    Cai, Longfei
    Xu, Chunxiu
    Zhou, Qing
    JOURNAL OF CHEMICAL EDUCATION, 2020, 97 (01) : 295 - 299
  • [24] A field amplification enhanced paper-based analytical device with a robust chemiluminescence detection module
    Zhang, Xiu-Xiu
    Liu, Jia-Juan
    Cai, Yu
    Zhao, Shuang
    Wu, Zhi-Yong
    ANALYST, 2019, 144 (02) : 498 - 503
  • [25] Composable paper-based analytical devices for determination of flavonoids
    Gutorova, Svetlana V.
    Apyari, Vladimir V.
    Kalinin, Vyacheslav I.
    Furletov, Aleksei A.
    Tolmacheva, Veronika V.
    Gorbunova, Maria V.
    Dmitrienko, Stanislava G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 331
  • [26] Fast and highly efficient multiplexed electrokinetic stacking on a paper-based analytical device
    Liu, Yu-Qi
    Ji, Bin
    Yan, Xiang-Hong
    Lv, Shuang
    Fang, Fang
    Guo, Xiao-Lin
    Wu, Zhi-Yong
    MICROCHEMICAL JOURNAL, 2022, 174
  • [27] Paper-Based Microfluidic Device with a Gold Nanosensor to Detect Arsenic Contamination of Groundwater in Bangladesh
    Chowdury, Mosfera A.
    Walji, Noosheen
    Mahmud, Md. Almostasim
    MacDonald, Brendan D.
    MICROMACHINES, 2017, 8 (03):
  • [28] Performance of electrokinetic stacking enhanced paper-based analytical device with smartphone for fast detection of fluorescent whitening agent
    Song, Yi-Zhen
    Zhang, Xiu-Xiu
    Ma, Biao
    Wu, Zhi-Yong
    Zhang, Zi-Qiang
    ANALYTICA CHIMICA ACTA, 2017, 995 : 85 - 90
  • [29] Bromine speciation by a paper-based sensor integrated with a citric acid/cysteamine fluorescent probe and smartphone detection
    Placer, Lorena
    Lavilla, Isela
    Pena-Pereira, Francisco
    Bendicho, Carlos
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358
  • [30] Electrochemical/visual dual-readout aptasensor for Ochratoxin A detection integrated into a miniaturized paper-based analytical device
    Zhang, Xiaobo
    Zhi, Hui
    Zhu, Mingzhen
    Wang, Fengya
    Meng, Hu
    Feng, Liang
    BIOSENSORS & BIOELECTRONICS, 2021, 180