De-bundled single-walled carbon nanotube-modified sensors for simultaneous differential pulse voltammetric determination of ascorbic acid, dopamine, and uric acid

被引:28
|
作者
Thirumalai, Dinakaran [1 ]
Subramani, Devaraju [2 ]
Yoon, Jang-Hee [3 ]
Lee, Jaewon [4 ]
Paik, Hyun-jong [2 ]
Chang, Seung-Cheol [5 ]
机构
[1] Pusan Natl Univ, Grad Dept Chem Mat, Busan 46241, South Korea
[2] Pusan Natl Univ, Dept Polymer Sci & Engn, Busan 46241, South Korea
[3] Korea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
[4] Pusan Natl Univ, Mol Inflammat Res Ctr Aging Intervent, Coll Pharm, Busan 46241, South Korea
[5] Pusan Natl Univ, Inst Biophysio Sensor Technol, Busan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
TRANSPARENT CONDUCTIVE FILMS; GRAPHENE OXIDE; MODIFIED ELECTRODE; FABRICATION; NANOPARTICLES; NANOMATERIALS; TRYPTOPHAN; DISPERSION; BIOSENSORS; OXIDATION;
D O I
10.1039/c7nj04371f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new approach based on differential pulse voltammetry (DPV) was developed for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) using a modified glassy carbon electrode (GCE). The sensor was constructed by a simple "one-step" technique, wherein de-bundled single-walled carbon nanotubes (SWCNTs) were drop-cast onto the GCE. Without de-bundling, the SWCNTs were poorly dispersed in aqueous solution and were ineffective for the one-step procedure. De-bundling of the SWCNTs was achieved using a small amount (0.1 wt%) of the synthesized polymer dispersant, sulfonated poly(ether sulfone) (SPES); the de-bundled SWCNTs had a high aspect ratio (length = 2.5 +/- 1.0 mu m; height = 2 +/- 1 nm, as determined using transmission electron microscopy and atomic force microscopy). The de-bundled SWCNTs also led to enhanced electrocatalytic activity and selectivity of the modified sensor for the simultaneous determination of AA, DA, and UA in DPV measurements: the peak-to-peak separation values were 221, 119, and 340 mV (vs. Ag/AgCl) for DA-AA, UA-DA, and AA-UA, respectively. The dynamic linear ranges for AA, DA, and UA were 0.2-1.6 mM, 5.0-50 mu M, and 5.0-60 mu M, and the detection limits were 10.6 mu M, 15 nM, and 113 nM (S/N = 3), respectively. The analytical performance of the developed sensor was demonstrated in the determination of AA and DA in commercial pharmaceutical samples (vitamin C tablets and DA injection). The characteristics of the modified sensor make it promising for the individual or simultaneous determination of AA, DA, and UA.
引用
收藏
页码:2432 / 2438
页数:7
相关论文
共 50 条
  • [31] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [32] Ionic liquid/single-walled carbon nanotubes composite film modified carbon-ceramic electrode as an electrochemical sensor for the simultaneous determination of epinephrine and uric acid
    Ayazi, Zahra
    Izadyar, Shima
    Habibi, Biuck
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2018, 65 (12) : 1510 - 1520
  • [33] Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode
    Mazloum-Ardakani, Mohammad
    Abolhasani-Soorki, Mahboobe
    Khoshroo, Alireza
    Sabaghian, Fariba
    Mirjalili, Bibi-Fatemeh
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2018, 17 (03): : 851 - 863
  • [34] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid at Pt Nanoparticles Decorated Multiwall Carbon Nanotubes Modified GCE
    Dursun, Zekerya
    Gelmez, Buket
    ELECTROANALYSIS, 2010, 22 (10) : 1106 - 1114
  • [35] Titanium dioxide-multiwalled carbon nanotube/polyimide composite film modified electrodes for simultaneous voltammetric detection of ascorbic acid, uric acid and dopamine as biomarker molecules
    Gungor, Oznur
    Ozgul, Onur
    Aksoy, Busra
    Okusluk, Funda
    Koytepe, Suleyman
    POLYMER BULLETIN, 2022, 79 (12) : 11051 - 11077
  • [36] Multiwall carbon nanotube modified glassy carbon electrode as voltammetric sensor for the simultaneous determination of ascorbic acid and caffeine
    Gupta, Vinod Kumar
    Jain, Ajay Kumar
    Shoora, Sudhir Kumar
    ELECTROCHIMICA ACTA, 2013, 93 : 248 - 253
  • [37] Easy modification of glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Thiagarajan, Soundappan
    Tsai, Tsung-Hsuan
    Chen, Shen-Ming
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) : 2712 - 2715
  • [38] Voltammetry Detection of Ascorbic Acid at Glassy Carbon Electrode Modified by Single-Walled Carbon Nanotube/Zinc Oxide
    Ngai, Koh Sing
    Tan, Wee Tee
    Zainal, Zulkarnain
    Zawawi, Ruzniza Mohd
    Zidan, Mohammed
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (08): : 10557 - 10567
  • [39] Flexible and conductive titanium carbide-carbon nanofibers for the simultaneous determination of ascorbic acid, dopamine and uric acid
    Guo, Qiaohui
    Wu, Tingting
    Liu, Lijuan
    Hou, Haoqing
    Chen, Shuiliang
    Wang, Li
    JOURNAL OF MATERIALS CHEMISTRY B, 2018, 6 (28) : 4610 - 4617
  • [40] Simultaneous voltammetric determination of uric acid and ascorbic acid using a carbon-paste electrode modified with malt-walled carbon Nanotubes/Nafion and Cobalt(II)-nitrosalophen
    Shahrokhian, Saeed
    Zare-Mehrjardi, Hamid Reza
    ELECTROANALYSIS, 2007, 19 (21) : 2234 - 2242