A cementless, elastic press-fit socket with and without screws A 2-year randomized controlled radiostereometric analysis of 37 hips

被引:23
作者
Pakvis, Dean [1 ]
Luites, Joan [3 ]
van Hellemondt, Gijs [2 ]
Spruit, Maarten [2 ]
机构
[1] Orthopaed Ctr OCON, Dept Orthopaed & Trauma Surg, Hengelo, Netherlands
[2] Sint Maartensklin, Dept Orthopaed Surg, Nijmegen, Netherlands
[3] Sint Maartensklin, Dept Res Dev & Educ, Nijmegen, Netherlands
关键词
ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS; ACETABULAR COMPONENT; FOLLOW-UP; RADIOGRAPHIC ANALYSIS; INITIAL STABILITY; COATED CUPS; ARTHROPLASTY; FIXATION; MIGRATION; BONE;
D O I
10.3109/17453674.2012.720116
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The acetabular component has remained the weakest link in hip arthroplasty regarding achievement of long-term survival. Primary fixation is a prerequisite for long-term performance. For this reason, we investigated the stability of a unique cementless titanium-coated elastic monoblock socket and the influence of supplementary screw fixation. Patient and methods During 2006-2008, we performed a randomized controlled trial on 37 patients (mean age 63 years (SD 7), 22 females) in whom we implanted a cementless press-fit socket. The socket was implanted with additional screw fixation (group A, n = 19) and without additional screw fixation (group B, n = 18). Using radiostereometric analysis with a 2-year follow-up, we determined the stability of the socket. Clinically relevant migration was defined as > 1 mm translation and > 2 degrees rotation. Clinical scores were determined. Results The sockets without screw fixation showed a statistically significantly higher proximal translation compared to the socket with additional screw fixation. However, this higher migration was below the clinically relevant threshold. The numbers of migratory sockets were not significantly different between groups. After the 2-year follow-up, there were no clinically relevant differences between groups A and B regarding the clinical scores. 1 patient dropped out of the study. In the others, no sockets were revised. Interpretation We found that additional screw fixation is not necessary to achieve stability of the cementless press-fit elastic RM socket. We saw no postoperative benefit or clinical effect of additional screw fixation.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 37 条
[1]  
Barrack RL, 1997, CLIN ORTHOP RELAT R, P211
[2]   Notes on the use and interpretation of radiostereometric analysis [J].
Derbyshire, Brian ;
Prescott, Robin J. ;
Porter, Martyn L. .
ACTA ORTHOPAEDICA, 2009, 80 (01) :124-130
[3]   Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup -: Randomised study of 96 hips followed with radiostereometry [J].
Digas, G ;
Thanner, J ;
Anderberg, C ;
Kärrholm, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (05) :1035-1043
[4]  
Diks MJF, 2005, HIP INT, V15, P71, DOI 10.5301/HIP.2008.5274
[5]   Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component - A follow-up study at a minimum of ten years [J].
Firestone, Daniel E. ;
Callaghan, John J. ;
Liu, Steve S. ;
Goetz, Devon D. ;
Sullivan, Patrick M. ;
Vittetoe, David A. ;
Johnston, Richard C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01) :126-132
[6]  
HADJARI MH, 1994, CLIN ORTHOP RELAT R, P117
[7]   The Relation between micromotion and Screw Fixation in Acetabular Cup [J].
Hsu, Jui-Ting ;
Lai, Kuo-An ;
Chen, Qingshan ;
Zobitz, Mark E. ;
Huang, Heng-Li ;
An, Kai-Nan ;
Chang, Chih-Han .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 84 (01) :34-41
[8]   The number of screws, bone quality, coefficient affect acetabular cup and friction stability [J].
Hsu, Jui-Ting ;
Chang, Chih-Han ;
Huang, Heng-Li ;
Zobitz, Mark E. ;
Chen, Weng-Pin ;
Lai, Kuo-An ;
An, Kai-Nan .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1089-1095
[9]   Effects of Screw Eccentricity on the Initial Stability of the Acetabular Cup in Artificial Foam Bone of Different Qualities [J].
Hsu, Jui-Ting ;
Lin, Dan-Jae .
ARTIFICIAL ORGANS, 2010, 34 (01) :E10-E16
[10]   POLYETHYLENE AND METAL DEBRIS GENERATED BY NON-ARTICULATING SURFACES OF MODULAR ACETABULAR COMPONENTS [J].
HUK, OL ;
MANJULA, B ;
BETTS, F ;
RIMNAC, CM ;
LIEBERMAN, JR ;
HUO, MH ;
SALVATI, EA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :568-574