Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:2
|
作者
Yang, Shih-Neng [1 ,2 ]
Lin, Chun-Wei [3 ]
Chang, Mu-Bai [4 ]
Zhang, Geoffrey G. [5 ]
Chou, Kuei-Ting [1 ,5 ]
Chiou, Yu-Rou [2 ]
Sun, Shung-Shung [1 ,6 ,7 ]
Lui, Louis [3 ]
Ho, Tsung-Jung [8 ]
Huang, Tzung-Chi [1 ,9 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 40402, Taiwan
[2] China Med Univ Hosp, Dept Radiat Oncol, Taichung 40402, Taiwan
[3] Cathay Gen Hosp, Dept Radiat Oncol, Taipei 10630, Taiwan
[4] Tainan Municipal An Nan Hosp, Dept Radiat Oncol, Tainan 70965, Taiwan
[5] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33647 USA
[6] China Med Univ Hosp, Dept Nucl Med, Taichung 40402, Taiwan
[7] China Med Univ Hosp, PET Ctr, Taichung 40402, Taiwan
[8] China Med Univ, Coll Chinese Med, Taichung 40402, Taiwan
[9] Asia Univ, Dept Bioinformat & Med Engn, Taichung 41354, Taiwan
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification; CELL LUNG-CANCER; STEREOTACTIC BODY RADIOTHERAPY; INTENSITY PROJECTION IMAGES; RESPIRATORY MOTION; DOSIMETRIC IMPACT; CONFORMAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; ORGAN MOTION; MAXIMUM;
D O I
10.1007/s40846-017-0367-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques-tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 +/- 0.51%, 0.17 +/- 0.45%, and 0.68 +/- 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 +/- 0.38%, 0.37 +/- 0.55% and 0.68 +/- 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [41] Evaluation of target volume and dose accuracy in intrafractional cases of lung cancer based on 4D-CT and 4D-CBCT images using an in-house dynamic thorax phantom
    Haqqi, Firyal Dhiyaul
    Sudarmaji, Arief
    Wibowo, Wahyu Edy
    Nasution, Nuruddin
    Handoko, Handoko
    Fauzia, Annisa Rahma
    Qudsi, Jihadil
    Pawiro, Supriyanto Ardjo
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 360 - 370
  • [42] Intraoperative radiotherapy IORT applicators for treatment of small skin lesions a phantom and planning study
    Lee, Ui-Seob
    Kim, Sung-woo
    Shin, Jun-Bong
    Jeong, Chiyoung
    Goh, Youngmoon
    Park, Min-Jae
    Kwak, Jungwon
    Song, Si Yeol
    Cho, Byungchul
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [43] Four-dimensional dose reconstruction system for lung cancer VMAT treatment: a 4D phantom study
    Hashimoto, M.
    Ito, Y.
    Tanaka, Y.
    Nakano, Masahiro
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (03): : 467 - 474
  • [44] Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different detector-phantom combinations: A comparative study
    Sarkar, Biplab
    Ghosh, Bhaswar
    Sriramprasath
    Mahendramohan, Sukumaran
    Basu, Ayan
    Goswami, Jyotirup
    Ray, Amitabh
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 144 - 150
  • [45] Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study
    Bowen, S. R.
    Nyflot, M. J.
    Herrmann, C.
    Groh, C. M.
    Meyer, J.
    Wollenweber, S. D.
    Stearns, C. W.
    Kinahan, P. E.
    Sandison, G. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3731 - 3746
  • [46] Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    Francescon, P
    Cora, S
    Chiovati, P
    MEDICAL PHYSICS, 2003, 30 (02) : 144 - 157
  • [47] Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study
    van der Werf, N. R.
    Willemink, M. J.
    Willems, T. P.
    Greuter, M. J. W.
    Leiner, T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (06) : 899 - 914
  • [48] Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study
    N. R. van der Werf
    M. J. Willemink
    T. P. Willems
    M. J. W. Greuter
    T. Leiner
    The International Journal of Cardiovascular Imaging, 2017, 33 : 899 - 914
  • [49] Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries
    Lopatiuk-Tirpak, O.
    Langen, K. M.
    Meeks, S. L.
    Kupelian, P. A.
    Zeidan, O. A.
    Maryanski, M. J.
    MEDICAL PHYSICS, 2008, 35 (09) : 3847 - 3859
  • [50] Enhancing Soft Tissue Differentiation with Different Dual-Energy CT Systems: A Phantom Study
    Gallo, Pasqualina
    D'Alessio, Andrea
    Pascuzzo, Riccardo
    Gallo, Salvatore
    Fumagalli, Maria Luisa
    Ortenzia, Ornella
    Tenconi, Chiara
    Cavatorta, Claudia
    Pignoli, Emanuele
    Ghetti, Caterina
    Bruzzone, Maria Grazia
    De Martin, Elena
    APPLIED SCIENCES-BASEL, 2024, 14 (05):