Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:2
|
作者
Yang, Shih-Neng [1 ,2 ]
Lin, Chun-Wei [3 ]
Chang, Mu-Bai [4 ]
Zhang, Geoffrey G. [5 ]
Chou, Kuei-Ting [1 ,5 ]
Chiou, Yu-Rou [2 ]
Sun, Shung-Shung [1 ,6 ,7 ]
Lui, Louis [3 ]
Ho, Tsung-Jung [8 ]
Huang, Tzung-Chi [1 ,9 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 40402, Taiwan
[2] China Med Univ Hosp, Dept Radiat Oncol, Taichung 40402, Taiwan
[3] Cathay Gen Hosp, Dept Radiat Oncol, Taipei 10630, Taiwan
[4] Tainan Municipal An Nan Hosp, Dept Radiat Oncol, Tainan 70965, Taiwan
[5] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33647 USA
[6] China Med Univ Hosp, Dept Nucl Med, Taichung 40402, Taiwan
[7] China Med Univ Hosp, PET Ctr, Taichung 40402, Taiwan
[8] China Med Univ, Coll Chinese Med, Taichung 40402, Taiwan
[9] Asia Univ, Dept Bioinformat & Med Engn, Taichung 41354, Taiwan
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification; CELL LUNG-CANCER; STEREOTACTIC BODY RADIOTHERAPY; INTENSITY PROJECTION IMAGES; RESPIRATORY MOTION; DOSIMETRIC IMPACT; CONFORMAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; ORGAN MOTION; MAXIMUM;
D O I
10.1007/s40846-017-0367-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques-tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 +/- 0.51%, 0.17 +/- 0.45%, and 0.68 +/- 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 +/- 0.38%, 0.37 +/- 0.55% and 0.68 +/- 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [31] On the commissioning of CT-simulation in radiotherapy treatment planning: A phantom study
    Fotina, I.
    Bogner, J.
    Georg, D.
    Polianc, K.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 254 - +
  • [32] Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit
    Rutonjski, Laza
    Petrovic, Borislava
    Baucal, Milutin
    Teodorovic, Milan
    Cudic, Ozren
    Gershkevitsh, Eduard
    Izewska, Joanna
    RADIATION ONCOLOGY, 2012, 7
  • [33] 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?
    Tseng, Yolanda D.
    Wootton, Landon
    Nyflot, Matthew
    Apisarnthanarax, Smith
    Rengan, Ramesh
    Bloch, Charles
    Sandison, George
    St James, Sara
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [34] Clinical introduction of Monte Carlo treatment planning: A different prescription dose for non-small cell lung cancer according to tumor location and size
    van Zyp, Noelle C. van der Voort
    Hoogeman, Mischa S.
    van de Water, Steven
    Levendag, Peter C.
    van der Holt, Bronno
    Heijmen, Ben J. M.
    Nuyttens, Joost J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 (01) : 55 - 60
  • [35] 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study
    Kurz, Christopher
    Bauer, Julia
    Unholtz, Daniel
    Richter, Daniel
    Stuetzer, Kristin
    Bert, Christoph
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) : 6227 - 6246
  • [36] Dose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom
    Mesbahi, A.
    Dadgar, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (04): : 345 - 354
  • [37] Pancreatic Tumor Motion on a Single Planning 4D-CT Does Not Correlate With Intrafraction Tumor Motion During Treatment
    Minn, A. Yuriko
    Schellenberg, Devin
    Maxim, Peter
    Suh, Yelin
    McKenna, Stephen
    Cox, Brett
    Dieterich, Sonja
    Xing, Lei
    Graves, Edward
    Goodman, Karyn A.
    Chang, Daniel
    Koong, Albert C.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (04): : 364 - 368
  • [38] A dose verification tool for high-dose-rate interstitial brachytherapy treatment planning in accelerated partial breast irradiation
    Marqa, Mohamad Feras
    Caudrelier, Jean-Michel
    Betrouni, Nacim
    BRACHYTHERAPY, 2012, 11 (05) : 359 - 368
  • [39] Increasing maximum tumor dose to manage range uncertainties in IMPT treatment planning
    Petit, Steven
    Seco, Joao
    Kooy, Hanne
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20) : 7329 - 7341
  • [40] Interplay Effect in Non-Gated Dynamic Treatment Delivery of a Lung Phantom with Simulated Respiratory Motion
    Desai, V.
    Fagerstrom, J.
    Bayliss, A.
    Kissick, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 174 - 174