Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:2
|
作者
Yang, Shih-Neng [1 ,2 ]
Lin, Chun-Wei [3 ]
Chang, Mu-Bai [4 ]
Zhang, Geoffrey G. [5 ]
Chou, Kuei-Ting [1 ,5 ]
Chiou, Yu-Rou [2 ]
Sun, Shung-Shung [1 ,6 ,7 ]
Lui, Louis [3 ]
Ho, Tsung-Jung [8 ]
Huang, Tzung-Chi [1 ,9 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 40402, Taiwan
[2] China Med Univ Hosp, Dept Radiat Oncol, Taichung 40402, Taiwan
[3] Cathay Gen Hosp, Dept Radiat Oncol, Taipei 10630, Taiwan
[4] Tainan Municipal An Nan Hosp, Dept Radiat Oncol, Tainan 70965, Taiwan
[5] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33647 USA
[6] China Med Univ Hosp, Dept Nucl Med, Taichung 40402, Taiwan
[7] China Med Univ Hosp, PET Ctr, Taichung 40402, Taiwan
[8] China Med Univ, Coll Chinese Med, Taichung 40402, Taiwan
[9] Asia Univ, Dept Bioinformat & Med Engn, Taichung 41354, Taiwan
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification; CELL LUNG-CANCER; STEREOTACTIC BODY RADIOTHERAPY; INTENSITY PROJECTION IMAGES; RESPIRATORY MOTION; DOSIMETRIC IMPACT; CONFORMAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; ORGAN MOTION; MAXIMUM;
D O I
10.1007/s40846-017-0367-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques-tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 +/- 0.51%, 0.17 +/- 0.45%, and 0.68 +/- 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 +/- 0.38%, 0.37 +/- 0.55% and 0.68 +/- 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [21] CT number variations due to different image acquisition and reconstruction parameters: a thorax phantom study
    Groell, R
    Rienmueller, R
    Schaffler, GJ
    Portugaller, HR
    Graif, E
    Willfurth, P
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (02) : 53 - 58
  • [22] A study of longitudinal tumor motion in helical tomotherapy using a cylindrical phantom
    Klein, Michael
    Gaede, Stewart
    Yartsev, Slav
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 52 - 61
  • [23] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
  • [24] Comparative evaluation of two dose-volume histogram prediction tools for treatment planning: Treatment planning quality and dose verification accuracy
    Nakano, Shoma
    Sasaki, Motoharu
    Nakaguchi, Yuji
    Kamomae, Takeshi
    Sakuragawa, Kanako
    Yamaji, Yuto
    Ikushima, Hitoshi
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2025, 33
  • [25] A comparison of dose distributions of HDR intracavitary brachytherapy using different sources and treatment planning systems
    Park, Dong-Wook
    Kim, Young Seok
    Park, Sung Ho
    Choi, Eun Kyung
    Do Ahn, Seung
    Lee, Sang-Wook
    Song, Si Yeol
    Kim, Jong Hoon
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1426 - 1431
  • [26] Comparison of Calculated Dose by Helical Tomotherapy Treatment Planning Machine and Measured Dose of Radiophotoluminescence Glass Dosimeter in Lung Lesions Using Rando Phantom
    Yamazaki, Hideya
    Iwama, Kazuki
    Nishimura, Takuya
    Iwai, Yasunori
    Aibe, Norihiro
    Takenaka, Tadashi
    Miyake, Shunsuke
    Tanaka, Eiichi
    Yoshida, Ken
    Oota, Yoshitaka
    Ikeno, Hiroyasu
    Nakamura, Satoakai
    Okabe, Haruumi
    ANTICANCER RESEARCH, 2013, 33 (04) : 1679 - 1684
  • [27] Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
    Knopf, Antje-Christin
    Hong, Theodore S.
    Lomax, Antony
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) : 7257 - 7271
  • [28] Evaluation of Imaging Dose From Different Image Guided Systems During Head and Neck Radiotherapy: A Phantom Study
    Cheng, Chun Shing
    Jong, Wei Loong
    Ung, Ngie Min
    Wong, Jeannie Hsiu Ding
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 357 - 362
  • [29] Dosimetric verification of treatment planning system superficial dose calculations for proton beam
    Rah, Jeong-Eun
    Shin, Dongho
    Park, Jeong-hoon
    Hwang, Ui-Jung
    Oh, Do Hoon
    Park, Sung Yong
    RADIATION MEASUREMENTS, 2013, 55 : 60 - 63
  • [30] Pre-treatment radiotherapy dose verification using Monte Carlo doselet modulation in a spherical phantom
    Townson, Reid W.
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08) : 1923 - 1934