Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:2
|
作者
Yang, Shih-Neng [1 ,2 ]
Lin, Chun-Wei [3 ]
Chang, Mu-Bai [4 ]
Zhang, Geoffrey G. [5 ]
Chou, Kuei-Ting [1 ,5 ]
Chiou, Yu-Rou [2 ]
Sun, Shung-Shung [1 ,6 ,7 ]
Lui, Louis [3 ]
Ho, Tsung-Jung [8 ]
Huang, Tzung-Chi [1 ,9 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 40402, Taiwan
[2] China Med Univ Hosp, Dept Radiat Oncol, Taichung 40402, Taiwan
[3] Cathay Gen Hosp, Dept Radiat Oncol, Taipei 10630, Taiwan
[4] Tainan Municipal An Nan Hosp, Dept Radiat Oncol, Tainan 70965, Taiwan
[5] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33647 USA
[6] China Med Univ Hosp, Dept Nucl Med, Taichung 40402, Taiwan
[7] China Med Univ Hosp, PET Ctr, Taichung 40402, Taiwan
[8] China Med Univ, Coll Chinese Med, Taichung 40402, Taiwan
[9] Asia Univ, Dept Bioinformat & Med Engn, Taichung 41354, Taiwan
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification; CELL LUNG-CANCER; STEREOTACTIC BODY RADIOTHERAPY; INTENSITY PROJECTION IMAGES; RESPIRATORY MOTION; DOSIMETRIC IMPACT; CONFORMAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; ORGAN MOTION; MAXIMUM;
D O I
10.1007/s40846-017-0367-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques-tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 +/- 0.51%, 0.17 +/- 0.45%, and 0.68 +/- 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 +/- 0.38%, 0.37 +/- 0.55% and 0.68 +/- 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [1] Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study
    Shih-Neng Yang
    Chun-Wei Lin
    Mu-Bai Chang
    Geoffrey G. Zhang
    Kuei-Ting Chou
    Yu-Rou Chiou
    Shung-Shung Sun
    Louis Lui
    Tsung-Jung Ho
    Tzung-Chi Huang
    Journal of Medical and Biological Engineering, 2018, 38 : 46 - 54
  • [2] A feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
    Xu, G.
    Xiong, Z.
    Wang, H.
    Jiang, H.
    Li, B.
    Liu, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 411 - 420
  • [3] Evaluation of Dose Difference in the Delivered Dose due to Lung Tumor Motion in Conventional, Conformal and IMRT Treatment Techniques using In-house Developed Dynamic Phantom
    Boopathy, Raghavendiran
    Nagarajan, Vivekanandan
    Rajasekaran, Dhanabalan
    Padmanaban, Sriram
    Sukumaran, Prabakar
    Sankarrao, Balakrishnan Irde
    Venkataraman, Lakshmanan Alathur
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2010, 30 (01) : 41 - 45
  • [4] dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3281 - S3285
  • [5] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2008, 35 (12) : 5434 - 5439
  • [6] Six degrees of freedom dynamic motion-including dose reconstruction in a commercial treatment planning system
    Skouboe, Simon
    De Roover, Robin
    Gammelmark Muurholm, Casper
    Ravkilde, Thomas
    Crijns, Wouter
    Hansen, Rune
    Depuydt, Tom
    Poulsen, Per Rugaard
    MEDICAL PHYSICS, 2021, 48 (03) : 1427 - 1435
  • [7] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom" (vol 35, pg 5434, 2008)
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2345 - 2345
  • [8] Optimization of acquisition parameters and accuracy of target motion trajectory for four-dimensional cone-beam computed tomography with a dynamic thorax phantom
    Shimohigashi Y.
    Araki F.
    Maruyama M.
    Nakaguchi Y.
    Nakato K.
    Nagasue N.
    Kai Y.
    Radiological Physics and Technology, 2015, 8 (1) : 97 - 106
  • [9] A four-dimensional dynamic conformal arc approach for real-time tumor tracking: A retrospective treatment planning study
    Yau, Timothy
    Kempe, Jeff
    Gaede, Stewart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [10] Technical Note: End-to-end verification of an MR-Linac using a dynamic motion phantom
    Liu, Xuechun
    Li, Chengqiang
    Zhu, Jian
    Gong, Guanzhong
    Sun, Hongqiang
    Li, Xu
    Sun, Mengdi
    Zhang, Zicheng
    Li, Baosheng
    Yin, Yong
    Li, Zhenjiang
    MEDICAL PHYSICS, 2021, 48 (09) : 5479 - 5489