Pharmacokinetic Evaluation of the Tau PET Radiotracer 18F-T807 (18F-AV-1451) in Human Subjects

被引:61
作者
Wooten, Dustin W. [1 ,2 ]
Guehl, Nicolas J. [1 ,2 ]
Verwer, Eline E. [1 ,2 ]
Shoup, Timothy M. [1 ,2 ]
Yokell, Daniel L. [1 ,2 ]
Zubcevik, Nevena [3 ]
Vasdev, Neil [1 ,2 ]
Zafonte, Ross D. [3 ,4 ]
Johnson, Keith A. [2 ]
El Fakhri, Georges [1 ,2 ]
Normandin, Marc D. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Gordon Ctr Med Imaging, Harvard Med Sch, Boston, MA USA
[2] Massachusetts Gen Hosp, Harvard Med Sch, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[3] Massachusetts Gen Hosp, Spaulding Rehabil Hosp, Dept Phys Med & Rehabil, Boston, MA USA
[4] Brigham & Womens Hosp, Harvard Med Sch, Boston, MA USA
关键词
tau; PET; F-18-T807; pharmacokinetics; kinetic modeling; POSITRON-EMISSION-TOMOGRAPHY; CHRONIC TRAUMATIC ENCEPHALOPATHY; ALZHEIMERS-DISEASE; NEUROFIBRILLARY PATHOLOGY; GRAPHICAL ANALYSIS; RADIOLIGAND; BINDING; TRACER; BRAIN; RADIOSYNTHESIS;
D O I
10.2967/jnumed.115.170910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
F-18-T807 is a PET radiotracer developed for imaging tau protein aggregates, which are implicated in neurologic disorders including Alzheimer disease and traumatic brain injury (TBI). The current study characterizes F-18-T807 pharmacokinetics in human subjects using dynamic PET imaging and metabolite-corrected arterial input functions. Methods: Nine subjects (4 controls, 3 with a history of TBI, 2 with mild cognitive impairment due to suspected Alzheimer disease) underwent dynamic PET imaging for up to 120 min after bolus injection of F-18-T807 with arterial blood sampling. Total volume of distribution (V-T) was estimated using compartmental modeling (1- and 2-tissue configurations) and graphical analysis techniques (Logan and multilinear analysis 1 [MA1] regression methods). Reference region-based methods of quantification were explored including Logan distribution volume ratio (DVR) and static SUV ratio (SUVR) using the cerebellum as a reference tissue. Results: The percentage of unmetabolized F-18-T807 in plasma followed a single exponential with a half-life of 17.0 +/- 4.2 min. Metabolite-corrected plasma radioactivity concentration fit a biexponential (half-lives, 18.1 +/- 5.8 and 2.4 +/- 0.5 min). F-18-T807 in gray matter peaked quickly (SUV > 2 at similar to 5 min). Compartmental modeling resulted in good fits, and the 2-tissue model with estimated blood volume correction (2Tv) performed best, particularly in regions with elevated binding. V-T was greater in mild cognitive impairment subjects than controls in the occipital, parietal, and temporal cortices as well as the posterior cingulate gyrus, precuneus, and mesial temporal cortex. High focal uptake was found in the posterior corpus callosum of a TBI subject. Plots from Logan and MA1 graphical methods became linear by 30 min, yielding regional estimates of V-T in excellent agreement with compartmental analysis and providing high-quality parametric maps when applied in voxelwise fashion. Reference region-based approaches including Logan DVR (t* 5 55 min) and SUVR (80-to 100-min interval) were highly correlated with DVR estimated using 2Tv (R-2 - 0.97, P < 0.0001). Conclusion: F-18-T807 showed rapid clearance from plasma and properties suitable for tau quantification with PET. Furthermore, simplified approaches using DVR (t* 5 55 min) and static SUVR (80-100 min) with cerebellar reference tissue were found to correlate highly with compartmental modeling outcomes.
引用
收藏
页码:484 / 491
页数:8
相关论文
共 35 条
[1]   Binding characteristics of radiofluorinated 6-dialkylamino-2-naphthylethylidene derivatives as positron emission tomography imaging probes for β-amyloid plaques in Alzheimer's disease [J].
Agdeppa, ED ;
Kepe, V ;
Liu, J ;
Flores-Torres, S ;
Satyamurthy, N ;
Petric, A ;
Cole, GM ;
Small, GW ;
Huang, SC ;
Barrio, JR .
JOURNAL OF NEUROSCIENCE, 2001, 21 (24) :art. no.-RC189
[2]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[3]   Improved methods for image registration [J].
Alpert, NM ;
Berdichevsky, D ;
Levin, Z ;
Morris, ED ;
Fischman, AJ .
NEUROIMAGE, 1996, 3 (01) :10-18
[4]  
[Anonymous], 2002, Model selection and multimodel inference: a practical informationtheoretic approach
[5]   Tau Positron Emission Tomography (PET) Imaging: Past, Present, and Future [J].
Ariza, Manuela ;
Kolb, Hartmuth C. ;
Moechars, Dieder ;
Rombouts, Frederik ;
Ignacio Andres, Jose .
JOURNAL OF MEDICINAL CHEMISTRY, 2015, 58 (11) :4365-4382
[6]   NEUROPATHOLOGICAL STAGING OF ALZHEIMER-RELATED CHANGES [J].
BRAAK, H ;
BRAAK, E .
ACTA NEUROPATHOLOGICA, 1991, 82 (04) :239-259
[7]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[8]   COMPARISON OF BOLUS AND INFUSION METHODS FOR RECEPTOR QUANTITATION - APPLICATION TO [F-18] CYCLOFOXY AND POSITRON EMISSION TOMOGRAPHY [J].
CARSON, RE ;
CHANNING, MA ;
BLASBERG, RG ;
DUNN, BB ;
COHEN, RM ;
RICE, KC ;
HERSCOVITCH, P .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (01) :24-42
[9]   Early Clinical PET Imaging Results with the Novel PHF-Tau Radioligand [F18]-T808 [J].
Chien, David T. ;
Szardenings, A. Katrin ;
Bahri, Shadfar ;
Walsh, Joseph C. ;
Mu, Fanrong ;
Xia, Chunfang ;
Shankle, William R. ;
Lerner, Alan J. ;
Su, Min-Ying ;
Elizarova, Arkadij ;
Kolb, Hartmuth C. .
JOURNAL OF ALZHEIMERS DISEASE, 2014, 38 (01) :171-184
[10]   Early Clinical PET Imaging Results with the Novel PHF-Tau Radioligand [F-18]-T807 [J].
Chien, David T. ;
Bahri, Shadfar ;
Szardenings, A. Katrin ;
Walsh, Joseph C. ;
Mu, Fanrong ;
Su, Min-Ying ;
Shankle, William R. ;
Elizarov, Arkadij ;
Kolb, Hartmuth C. .
JOURNAL OF ALZHEIMERS DISEASE, 2013, 34 (02) :457-468