A Plaster Cast Contact Scan Method to Assess the Accuracy of Full-Arch Computer-Aided Implant Surgery

被引:2
作者
Franchina, Alessio
Stefanelli, Luigi Vito [1 ]
Ferri, Agnese [2 ]
Pellegrino, Gerardo [2 ]
Di Carlo, Stefano [1 ]
De Angelis, Francesca [1 ]
机构
[1] Sapienza Univ Rome, Dept Oral & Maxillofacial Sci, Rome, Italy
[2] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Oral & Maxillofacial Surg, Bologna, Italy
关键词
3D; CAD/CAM; computer; guided surgery; data accuracy; dental implant; guidance; immediate loading; osseointegrated implants; surgery; surgical guide; surgical procedure; STEREOLITHOGRAPHIC SURGICAL GUIDES; RANDOMIZED CLINICAL-TRIAL; COMPLICATION RATES; EDENTULOUS MAXILLA; DYNAMIC NAVIGATION; PLACEMENT; BONE; SURVIVAL; TOMOGRAPHY; DENTISTRY;
D O I
10.11607/jomi.9199
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was accuracy assessment of placed implants in full-arch cases using specific software and hardware to perform static computer-assisted implantology and immediately loaded prostheses. The degree of deviation existing between planned and achieved implants was carried out by a new noninvasive measurement procedure of the implant position performed on stone casts. Materials and Methods: Fourteen stone casts retrieved from 14 full-arch fully guided implant treatments were selected to perform the study. Each cast, manufactured for the surgical treatment by using a specific laboratory kit, was obtained from the respective surgical guide. A sleeve for each implant was embedded into the guide, which helped the examiners to manufacture a stone cast per guide containing the implant analogs, which was used to recover the final position of the planned implants. A total sample of 60 implants were assessed. The postoperative casts, poured to produce the immediate prostheses, were then processed by a contact (or tactile) scanner, and the generated standard tessellation language (STL) files were overlapped (best-fit alignment) using engineering software that revealed all the measured discrepancies. In terms of accuracy, differences relating to arch, assessed bone quality, implant length, and drill length (prolongation short or long) were reported. Results: The use of a noninvasive tactile scanner revealed mean entry point horizontal deviations of 0.30 mm (SD: 0.39 mm), mean entry point vertical deviations of 0.20 mm (SD: 0.25 mm), mean apical horizontal deviations of 0.50 mm (SD: 0.73 mm), and mean apical vertical deviations of 0.24 mm (SD: 0.28 mm). The frontal and lateral angular deviations were investigated, and corresponding mean values of 1.99 degrees (SD: 2.30 degrees) and 1.80 degrees (SD: 2.44 degrees) were detected. Conclusion: The reported results demonstrate that the contact tactile scan is a viable and biologic way to assess implant deviations.
引用
收藏
页码:756 / 762
页数:7
相关论文
共 47 条
  • [1] ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
  • [2] Cone Beam Computed Tomography in Implant Dentistry: A Systematic Review Focusing on Guidelines, Indications, and Radiation Dose Risks
    Bornstein, Michael M.
    Scarfe, William C.
    Vaughn, Vida M.
    Jacobs, Reinhilde
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 55 - 77
  • [3] Implant placement in oral squamous cells carcinoma patients treated with chemoradiotherapy: "Sapienza Head and Neck Unit" clinical recommendations
    Brauner, E.
    Musio, D.
    Mezi, S.
    Ciolfi, A.
    Maghella, F.
    Cassoni, A.
    De Angelis, F.
    Guarino, G.
    Romeo, U.
    Tenore, G.
    Piesco, G.
    De Felice, F.
    Tombolini, V.
    Valentini, V.
    Polimeni, A.
    Di Carlo, S.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (22) : 9923 - 9930
  • [4] Brauner E., 2018, J. Int. Dent. Med. Res, V11, P1
  • [5] Cassetta M, 2012, INT J ORAL MAX IMPL, V27, P655
  • [6] A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous Maxillae
    D'haese, Jan
    Van De Velde, Tommie
    Elaut, Lucien
    De Bruyn, Hugo
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 293 - 303
  • [7] De Angelis F, 2017, CLIN TER, V168, pE229, DOI 10.7417/T.2017.2011
  • [8] De Angelis F, 2017, EUR REV MED PHARMACO, V21, P433
  • [9] De Angelis F, 2017, J INT DENT MED RES, V10, P52
  • [10] Implant-Supported Rehabilitation Using GBR Combined with Bone Graft on a Reconstructed Maxilla with the Fibula Free Flap
    Di Carlo, S.
    Valentini, V.
    Grasso, E.
    De Angelis, F.
    Piccoli, L.
    Quarato, A.
    Jamshir, S.
    Brauner, E.
    [J]. CASE REPORTS IN DENTISTRY, 2019, 2019