Experimental studies on few-view reconstruction for high-resolution micro-CT

被引:16
|
作者
Sen Sharma, Kriti [1 ]
Jin, Xin [2 ]
Holzner, Christian [3 ]
Narayanan, Shree [1 ]
Liu, Baodong [4 ]
Wang, Dong [5 ]
Agah, Masoud [1 ]
Wang, Libing [5 ]
Yu, Hengyong [4 ]
Wang, Ge [6 ]
机构
[1] Virginia Tech, Dept Elect & Comp Engn, Blacksburg, VA USA
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Xradia Inc, Pleasanton, CA USA
[4] Wake Forest Univ Hlth Sci, VT WFU Sch Biomed Engn & Sci, Biomed Imaging Div, Winston Salem, NC USA
[5] Virginia Tech, Dept Civil & Environm Engn, Blacksburg, VA USA
[6] Rensselaer Polytech Inst, Biomed Imaging Ctr, Troy, NY USA
关键词
Few-view reconstruction; micro-CT; compressed sensing; TV minimization; SART-TV; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; FAN-BEAM; ALGORITHM;
D O I
10.3233/XST-130364
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-resolution micro-CT offers 3D non-destructive imaging but scan times are prohibitively large in many cases. Advancements in image reconstruction offer great reduction in number of views while maintaining reconstruction accuracy; yet filtered back projection remains the de facto standard. An extensive study of few-view reconstruction using compressed-sensing based iterative techniques is carried out. Also, a novel 3D micro-CT phantom is proposed, and used for analyzing reconstruction accuracy. Numerical tests, and studies on real micro-CT data show that if measurement noise in projections is not extremely high, the number of views may be reduced to 1/8th of the typically acquired view numbers. The study motivates the adoption of advanced reconstruction techniques to allow faster scanning, lower dosage, and reduced data size in high-resolution micro-CT.
引用
收藏
页码:25 / 42
页数:18
相关论文
共 50 条
  • [31] Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark
    Keuler, Andreas
    Taschner, Christian
    Brockmann, Marc Alexander
    Boll, Hanne
    Foerster, Katharina
    Lutz, Lisa
    Herrmann-Frank, Annegret
    Lelgemann, Monika
    Schumacher, Martin
    NEURORADIOLOGY, 2014, 56 (04) : 315 - 323
  • [32] Micro-CT of carotid arteries: A tool for experimental studies
    Mohr, A
    Wenke, R
    Roemer, FW
    Lynch, JA
    Gatzka, C
    Priebe, M
    Guermazi, A
    Grigorian, M
    Heller, M
    Mueller-Huelsbeck, S
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (06) : 651 - 654
  • [33] Accurate Image Reconstruction of Few-view Ptychrography X-ray Computed Tomography
    Fu, J.
    Wang, J. Z.
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 1505 - 1509
  • [34] Spatial-resolution enhancement in micro-CT
    Pan, XC
    Yu, LF
    Kao, CM
    Pelizzari, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3244 - 3247
  • [35] A Multi-Resolution Approach to Retrospectively-Gated Cardiac Micro-CT Reconstruction
    Clark, D. P.
    Johnson, G. A.
    Badea, C. T.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [36] Reconstruction of limited-angle and few-view nano-CT image via total variation iterative reconstruction
    Liang, Zhiting
    Guan, Yong
    Liu, Gang
    Bian, Rui
    Zhang, Xiaobo
    Xiong, Ying
    Tian, Yangchao
    X-RAY NANOIMAGING: INSTRUMENTS AND METHODS, 2013, 8851
  • [37] A very fast iterative algorithm for TV-regularized image reconstruction with applications to low-dose and few-view CT
    Kudo, Hiroyuki
    Yamazaki, Fukashi
    Nemoto, Takuya
    Takaki, Keita
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [38] TV-based conjugate gradient method and discrete L-curve for few-view CT reconstruction of X-ray in vivo data
    Yang, Xiaoli
    Hofmann, Ralf
    Dapp, Robin
    van de Kamp, Thomas
    Rolo, Tomy dos Santos
    Xiao, Xianghui
    Moosmann, Julian
    Kashef, Jubin
    Stotzka, Rainer
    OPTICS EXPRESS, 2015, 23 (05): : 5368 - 5387
  • [39] Improving Spatial-Resolution in High Cone-Angle Micro-CT by Source Deblurring
    Li, Heyang
    Kingston, Andrew
    Myers, Glenn
    Recur, Benoit
    Turner, Michael
    Sheppard, Adrian
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [40] A study on projection distribution of few-view reconstruction with total variation constraint
    Zhang, Li
    Duan, Xinhui
    Xing, Yuxiang
    Chen, Zhiqiang
    Cheng, Jianping
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913