Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation

被引:107
作者
Brady, Samuel L. [1 ]
Kaufman, Robert A. [1 ]
机构
[1] St Jude Childrens Res Hosp, Dept Radiol Sci, Memphis, TN 38139 USA
关键词
INDEX;
D O I
10.1148/radiol.12120131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare five methodologies the American Association of Physicists in Medicine Report 204 used to calculate size-specific dose estimates (SSDEs) for pediatric computed tomography (CT). Materials and Methods: The institutional review board waived consent for this HIPAA-compliant retrospective study. The five SSDE methodologies were investigated for calculation variation based on volumetric CT dose index (CTDI), or CTDIvol, of chest, abdominal, and pelvic CT. SSDE calculations were derived from a predominantly pediatric population of 186 patients retrospectively and consecutively analyzed from June through November 2011. Eighty (43%) of the 186 patients were female, and 106 (57%) were male. Mean patient age was 8.6 years +/- 6.3 (standard deviation), the age range was 1 month to 28 years, and mean weight was 37.7 kg +/- 33.1, with a range of 3.4-146.6 kg. SSDE conversion factors were derived from anteroposterior (AP) and lateral dimensions measured on the patient's CT radiograph. The measurements were either used independently, or as a summation, or to calculate the patient's effective diameter; additionally, SSDE was derived on the basis of the patient's age (International Commission on Radiation Units Report 74 data). SSDE conversion factors were applied to CTDIvol data that corrected for both 16- and 32-cm-diameter CTDI phantom measurements. SSDE data were summarized by using the patient's originally prescribed weight-based CT scanning protocols. Data were summarized by using descriptive statistics. Results: SSDEs derived from individual measurements varied 2%-12%. The combination of measurements (sum or effective diameter) varied 0.9%-2%. The age approach varied by an average of 2% (in the younger population [0-13 years]), but up to 44%, with an average of 18% (in the older population [14-18 years]). No SSDE correction was required for patients of varying size who weighed 36 kg or less when CTDIvol was measured by using a 16-cm CTDI phantom or for patients weighing 100-140 kg when CTDIvol was measured by using a 32-cm phantom. CTDIvol measured by using a 32-cm phantom in patients weighing between 36 and 100 kg and patients weighing more than 140 kg differed from SSDE by an average of 35%. An average difference of 1% was found between male and female SSDE-corrected values when the two sexes were compared within the same CT weight scanning categories. Conclusion: The combination of AP and lateral measurements should be used to determine SSDE correction factors when possible. For pediatric patients, CTDIvol calculated with a 32-cm phantom requires SSDE conversion to more accurately estimate patient dose; CTDIvol calculated with a 16-cm phantom for pediatric patients weighing 36 kg or less does not require SSDE conversion. (C) RSNA, 2012
引用
收藏
页码:832 / 840
页数:9
相关论文
共 12 条
  • [1] [Anonymous], 2009, National Council on Radiation Protection and Measurement report No. 160: Ionizing radiation exposure of the population of the United States
  • [2] Boone JM., 2011, Report of AAPM Task Group, V204
  • [3] The trouble with CTDI100
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1364 - 1371
  • [4] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [5] GE Healthcare, 2010, Lightspeed VCT. 5340596-1EN (rev 5), Patent No. 53405961
  • [6] Patient radiation doses from adult and pediatric CT
    Huda, Walter
    Vance, Awais
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 540 - 546
  • [7] Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?
    Huda, Walter
    Mettler, Fred A.
    [J]. RADIOLOGY, 2011, 258 (01) : 236 - 242
  • [8] National Conference on Dose Reduction in CT, with an emphasis on pediatric patients
    Linton, OW
    Mettler, FA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 321 - 329
  • [9] CT Dose Index and Patient Dose: They Are Not the Same Thing
    McCollough, Cynthia H.
    Leng, Shuai
    Yu, Lifeng
    Cody, Dianna D.
    Boone, John M.
    McNitt-Gray, Michael F.
    [J]. RADIOLOGY, 2011, 259 (02) : 311 - 316
  • [10] Report Committee, 2005, J ICRU, V5, pi