Mitral prosthetic size predictor in minimally invasive mitral valve replacement

被引:5
作者
Vo, Anh T. [1 ]
Nguyen, Nguyen T. H. [2 ]
Le, Khoi M. [1 ]
Vuong, Nguyen L. [3 ]
Nguyen, Trang T. T. [1 ]
Vu, Thanh T. [2 ]
Hoang, Sy, V [4 ]
Nguyen, Dinh H. [1 ,2 ]
机构
[1] Univ Med & Pharm Ho Chi Minh City, Univ Med Ctr, Cardiovasc Surg Dept, 215 Hong Bang St,Dist 05, Ho Chi Minh City, Vietnam
[2] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Thorac & Cardiovasc Surg, Ho Chi Minh City, Vietnam
[3] Univ Med & Pharm Ho Chi Minh City, Fac Publ Hlth, Dept Med Stat & Informat, Ho Chi Minh City, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Internal Med, Ho Chi Minh City, Vietnam
关键词
Prosthetic size predictor; Annular rupture; Minimally invasive approach; Cardiac computed tomography; Transthoracic echocardiography; MISMATCH; SURGERY;
D O I
10.1186/s13019-020-01197-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Minimally invasive mitral valve replacement has become popular across the world. However, annular rupture and patient - prosthetic mismatch (PPM) are still problematic, particularly in the Asian population. To avoid this, a predictor model could be beneficial. Our study aimed to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses. Methods From January 2018 to December 2019, a total number of 96 patients underwent minimally invasive mitral valve replacement. The association between imaging measurements and the outcome was checked by scatter plot and Pearson's correlation coefficient. Univariable linear regression was used to build the prediction model. Results The three strongest correlations for the whole population are the following features: Mean TTE diameter (0.702), mean diameter on CT lowest plane through the mitral annulus (0.679), and area-derived diameter on CT highest plane through the mitral annulus (0.665). The prosthetic size of the tissue valve group was more correlated to the calculated annulus diameters than that of the mechanical valve group. Tissue valve size predictor models based on these calculated diameters were 16.19 + 0.27 x d (r = 0.744), 12.74 + 0.44 x d (r = 0.756) and 12.79 + 0.38 x d (r = 0.730), respectively. Conclusion Mitral prosthetic size could be predicted based on the mitral diameters measured on TTE and CT scan. The overall correlation coefficient varied from 0.665 (CT Scan) to 0.702 (TTE). These models performed better when applied to bioprosthesis.
引用
收藏
页数:7
相关论文
共 13 条
  • [1] Minimally Invasive Mitral Valve Surgery for Rheumatic Valve Disease
    Anh Tuan Vo
    Khoi Minh Le
    Trang Thu Nguyen
    Thien Tam Vu
    Chuong Tran Viet Pham
    Huy Quoc Tuan Ngo
    Tri Quang Le
    Dinh Hoang Nguyen
    [J]. HEART SURGERY FORUM, 2019, 22 (05) : E390 - E395
  • [2] PREOPERATIVE TWO-DIMENSIONAL ECHOCARDIOGRAPHIC PREDICTION OF PROSTHETIC AORTIC AND MITRAL-VALVE SIZE IN CHILDREN
    CALDWELL, RL
    GIROD, DA
    HURWITZ, RA
    MAHONY, L
    KING, H
    BROWN, J
    [J]. AMERICAN HEART JOURNAL, 1987, 113 (04) : 873 - 878
  • [3] The global burden of group A streptococcal diseases
    Carapetis, JR
    Steer, AC
    Mulholland, EK
    Weber, M
    [J]. LANCET INFECTIOUS DISEASES, 2005, 5 (11) : 685 - 694
  • [4] Carpentier A., 2011, Carpentier's reconstructive valve surgery
  • [5] Cheng DCH, 2011, INNOVATIONS, V6, P84, DOI 10.1097/IMI.0b013e3182167feb
  • [6] Quantitative analysis of mitral valve morphology in atrial functional mitral regurgitation using real-time 3-dimensiona echocardiography atrial functional mitral regurgitation
    Cong, Tao
    Gu, Jinping
    Lee, Alex Pui-Wai
    Shang, Zhijuan
    Sun, Yinghui
    Sun, Qiaobing
    Wei, Hong
    Chen, Na
    Sun, Siyao
    Fu, Tingting
    [J]. CARDIOVASCULAR ULTRASOUND, 2018, 16
  • [7] Ghosh P., 1999, ASIAN CARD THORAC AN, V7, P190
  • [8] Dynamic Changes of the Mitral Valve Annulus New Look at Mitral Valve Diseases
    Hagege, Albert A.
    Carpentier, Alain
    Levine, Robert A.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (05)
  • [9] Patient-Prosthesis Mismatch After Mitral Valve Replacement: A Propensity Score Analysis
    Hwang, Ho Young
    Kim, Yong Han
    Kim, Kyung-Hwan
    Kim, Ki-Bong
    Ahn, Hyuk
    [J]. ANNALS OF THORACIC SURGERY, 2016, 101 (05) : 1796 - 1803
  • [10] RUPTURE OF LEFT-VENTRICLE FOLLOWING MITRAL-VALVE REPLACEMENT
    KARLSON, KJ
    ASHRAF, MM
    BERGER, RL
    [J]. ANNALS OF THORACIC SURGERY, 1988, 46 (05) : 590 - 597