Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid®) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients

被引:89
作者
Chiapasco, M. [1 ]
Casentini, P. [1 ]
Zaniboni, M. [1 ]
Corsi, E. [1 ]
Anello, T. [1 ]
机构
[1] Univ Milan, San Paolo Hosp, Dept Med Surg & Dent, Unit Oral Surg, I-20142 Milan, Italy
关键词
bone atrophy; dental prosthesis; narrow diameter; osseointegrated implant; partial edentulism; total edentulism; SINGLE-TOOTH; FOLLOW-UP; AUGMENTATION PROCEDURES; CLINICAL-EVALUATION; ITI IMPLANTS; SYSTEM;
D O I
10.1111/j.1600-0501.2011.02296.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim of the study (i) To evaluate the survival and success rates of the new Roxolid narrow diameter implant placed in horizontally deficient ridges; and (ii) to evaluate the incidence of prosthetic complications. Materials and methods In a 24-month period (20092010) 18 partially or totally edentulous patients received 51 Straumann Roxolid (13 tissue level, 38 bone level) implants. Prosthetic loading of implants was either immediate (four implants; one patient) or delayed (212 similar to months after placement; 47 implants; 17 patients). The patients were rehabilitated with either fixed (16 patients; 45 implants) or removable (two patients; six implants) prostheses. Results All implants successfully achieved osseointegration and all patients completed the planned prosthetic rehabilitation. Peri-implant bone resorption values ranged from 0 to 1 similar to mm at the end of the observation period (range: 319 similar to months). Implant survival and success rates were therefore 100%. No prosthetic complications occurred and all implants are still in function; therefore the prosthesis success rate was 100%. Conclusion Narrow diameter implants fabricated with the new titaniumzirconium alloy were demonstrated to be reliable in supporting both fixed and removable prosthetic rehabilitations in horizontally deficient ridges. Implant survival, peri-implant bone resorption, and prosthetic complication rates were consistent with those reported in the literature for standard diameter implants placed in non-deficient edentulous ridges.
引用
收藏
页码:1136 / 1141
页数:6
相关论文
共 27 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P233
[2]   The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study [J].
Allum, Simon Rupert ;
Tomlinson, Rachel Anne ;
Joshi, Rajendra .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) :553-559
[3]  
Andersen E, 2001, INT J ORAL MAX IMPL, V16, P217
[4]  
[Anonymous], 1986, INT J ORAL MAX IMPL
[5]   Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles [J].
Arvidson, K ;
Bystedt, H ;
Frykholm, A ;
von Konow, L ;
Lothigius, E .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) :225-234
[6]   Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[7]   Augmentation procedures for the rehabilitation of deficient edentulous ridges with oral implants [J].
Chiapasco, Matteo ;
Zaniboni, Marco ;
Boisco, Maurizio .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :136-159
[8]  
Chiapasco M, 2009, INT J ORAL MAX IMPL, V24, P237
[9]   Retrospective evaluation of mandibular incisor replacement with narrow neck implants [J].
Cordaro, Luca ;
Torsello, Ferruccio ;
Di Torresanto, Vincenzo Mirisola ;
Rossini, Carlo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :730-735
[10]  
Davarpanah M, 2000, J Esthet Dent, V12, P186, DOI 10.1111/j.1708-8240.2000.tb00221.x