Thermal, mechanical and chemical influences on the performance of optical fibres for distributed temperature sensing in a hot geothermal well

被引:36
作者
Reinsch, Thomas [1 ]
Henninges, Jan [1 ]
Asmundsson, Ragnar [2 ]
机构
[1] Helmholtz Ctr Potsdam, GFZ German Res Ctr Geosci, D-14473 Potsdam, Germany
[2] Heat Res & Dev, Varmalausnir, Akureyri, Iceland
关键词
Distributed temperature sensing (DTS); Iceland; High temperature geothermal well; Optical fibre; Optical time domain reflectometry (OTDR); DTS;
D O I
10.1007/s12665-013-2248-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Structural well-bore integrity is an important issue for sustainable provision of geothermal energy. Raman scattering based fibre optic distributed temperature sensing (DTS) can help to monitor the status of a well and therefore help to optimize expensive work-over activities. This study reports on the installation of a fibre-optic cable in the cemented annulus behind the anchor casing in the high temperature geothermal well HE-53, HellisheiA degrees i geothermal field, SW Iceland. Although the cable has been damaged during the installation, temperature data could be acquired during the entire length of installation down to 261.3 m. Temperature measurements were performed during the installation in spring 2009, during the onset of a flow test in summer 2009 and after a 8.5 month shut-in period in summer 2010. During the flow test, maximum temperatures of 230 A degrees C were measured after 2 weeks fluid production. Using optical time domain reflectometry (OTDR), attenuation measurements at 850 and 1,300 nm enabled to identify mechanical, thermal, and chemical degradation along the optical fibre. The observed degradation led to erroneous temperature readings and limits, due to the optical budget of the DTS system, the accessible length of the fibre. The characteristics and the influence of the different degradation mechanisms on the accuracy of the DTS measurements are discussed and recommendations for an optimized installation are given.
引用
收藏
页码:3465 / 3480
页数:16
相关论文
共 50 条
[1]  
Albertsson A., 2003, OS2003007 3, P33
[2]   Distributed temperature measurements using optical fibre technology in an underground mine environment [J].
Aminossadati, Sailed M. ;
Mohammed, Nayeemuddin M. ;
Shemshad, Javad .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2010, 25 (03) :220-229
[3]   Geothermal systems in Iceland: Structure and conceptual models .1. High-temperature areas [J].
Arnorsson, S .
GEOTHERMICS, 1995, 24 (5-6) :561-602
[4]  
Bignall G, 2010, P WORLD GEOTH C 2010
[5]  
Buck J.A., 2004, Fundamentals of optical fibers
[6]  
Cella J.A., 1996, In Polyimides: Fundamentals and Applications, P343
[7]   STATIC FORMATION TEMPERATURE FROM WELL LOGS - EMPIRICAL METHOD [J].
DOWDLE, WL ;
COBB, WM .
JOURNAL OF PETROLEUM TECHNOLOGY, 1975, 27 (NOV) :1326-1330
[8]   The system H2O-NaCl.: Part I:: Correlation formulae for phase relations in temperature-pressure-composition space from 0 to 1000 °C, 0 to 5000 bar, and 0 to 1 XNaCl [J].
Driesner, Thomas ;
Heinrich, Christoph A. .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (20) :4880-4901
[9]   Application of optical-fiber temperature logging - An example in a sedimentary environment [J].
Forster, A ;
Schrotter, J ;
Merriam, DF ;
Blackwell, DD .
GEOPHYSICS, 1997, 62 (04) :1107-1113
[10]  
FRANCKE H, 2012, ENV EARTH SCI