Long-term follow-up results of the SMART coil in the endovascular treatment of intracranial aneurysms

被引:5
作者
McAvoy, Malia B. [1 ]
Cappuzzo, Justin M. [2 ]
Stapleton, Christopher J. [3 ]
Koch, Matthew J. [3 ]
Raymond, Scott B. [4 ]
Torok, Collin M. [5 ]
Patel, Aman B. [3 ]
机构
[1] Harvard Med Sch, Massachusetts Inst Technol, Harvard MIT Hlth Sci & Technol, Boston, MA 02115 USA
[2] SUNY Buffalo, Dept Neurosurg, Buffalo, NY USA
[3] Massachusetts Gen Hosp, Dept Neurosurg, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[5] St Paul Radiol, St Paul, MN USA
关键词
Intracranial aneurysm; endovascular coil embolization; aneurysmal subarachnoid hemorrhage; EMBOLIZATION; TRIAL; CLASSIFICATION; EXPERIENCE; HERNIATION; OCCLUSION;
D O I
10.1177/1591019920956890
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The Penumbra SMART coil is a novel device that becomes progressively softer from its distal to proximal end to maximize coil packing and prevent microcatheter prolapse or coil migration. Here, we report a large series of patients detailing the long-term experience of a single institution using the SMART coil among patients with intracranial aneurysms (IAs). Methods Prospective data of 105 consecutive patients with 106 IAs treated using SMART coils was collected between March 2015 and July 2018. Clinical and angiographic data were analyzed. Results Forty-nine patients (46.7%) presented with subarachnoid hemorrhage and 16 (14.2%) had recurrent aneurysms. Two patients had minor intraprocedural ruptures and remained neurologically stable. One patient had a thromboembolic complication with progressive neurologic decline. There was only one case microcatheter prolapse related to placement of a stent before coiling. An initial post-treatment modified Raymond-Roy Occlusion Classification (mRROC) I or II closure was achieved in 56 (52.8%) aneurysms. The average time to last follow-up was 8.4 months at which 70 (81.4%) aneurysms had mRROC I or II occlusion and a major recurrence was seen in 5 (5.8%) patients. Thirteen (12.3%) aneurysms required re-treatment of which one aneurysm was clipped. Conclusions The Penumbra SMART coil is safe and effective for the endovascular treatment of appropriately selected IAs. Additional studies at multiple centers comparing safety and efficacy profile over long-term periods to other mainstream coils are necessary.
引用
收藏
页码:200 / 206
页数:7
相关论文
共 20 条
[1]   The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil [J].
Bendok, Bernard R. ;
Abi-Aad, Karl R. ;
Ward, Jennifer D. ;
Kniss, Jason F. ;
Kwasny, Mary J. ;
Rahme, Rudy J. ;
Aoun, Salah G. ;
El Ahmadieh, Tarek Y. ;
El Tecle, Najib E. ;
Zammar, Samer G. ;
Aoun, Rami James N. ;
Patra, Devi P. ;
Ansari, Sameer A. ;
Raymond, Jean ;
Woo, Henry H. ;
Fiorella, David ;
Dabus, Guilherme ;
Milot, Genevieve ;
Almandoz, Josser E. Delgado ;
Scott, John A. ;
DeNardo, Andrew J. ;
Dashti, Shervin R. .
NEUROSURGERY, 2020, 86 (05) :615-624
[2]  
Cottier JP, 2001, AM J NEURORADIOL, V22, P345
[3]   SMART coils for intracranial aneurysm repair - a single center experience [J].
Daniel, Behme ;
Henrik, Sack ;
Ioannis, Tsogkas ;
Veit, Rohde ;
Marios-Nikos, Psychogios .
BMC NEUROLOGY, 2020, 20 (01)
[4]   Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms [J].
Dinc, H ;
Kuzeyli, K ;
Kosucu, P ;
Sari, A ;
Cekirge, S .
NEURORADIOLOGY, 2006, 48 (04) :269-272
[5]   Coiling of Intracranial Aneurysms A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates [J].
Ferns, Sandra P. ;
Sprengers, Marieke E. S. ;
van Rooij, Willem Jan ;
Rinkel, Gabriel J. E. ;
van Rijn, Jeroen C. ;
Bipat, Shandra ;
Sluzewski, Menno ;
Majoie, Charles B. L. M. .
STROKE, 2009, 40 (08) :E523-E529
[6]   Intracranial aneurysms treatment with Barricade coils: Safety and 1-year efficacy in a prospective, single-center series [J].
Guerreiro-Simoes, Raoul ;
Soize, Sebastien ;
Gawlitza, Matthias ;
Manceau, Pierre-Francois ;
Pierot, Laurent .
JOURNAL OF NEURORADIOLOGY, 2019, 46 (05) :331-335
[7]   SMART coils for intracranial aneurysm embolization: Initial outcomes [J].
Ilyas, Adeel ;
Buell, Thomas J. ;
Chen, Ching-Jen ;
Ding, Dale ;
Raper, Daniel M. S. ;
Taylor, Davis G. ;
Sokolowski, Jennifer D. ;
Liu, Kenneth C. .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 164 :87-91
[8]   Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: Treatment with intracranial stent placement: Two technical case reports [J].
Lavine, SD ;
Larsen, DW ;
Giannotta, SL ;
Teitelbaum, GP .
NEUROSURGERY, 2000, 46 (04) :1013-1017
[9]  
Lubicz B, 2005, AM J NEURORADIOL, V26, P1342
[10]   Stent Management of Coil Herniation in Embolization of Internal Carotid Aneurysms [J].
Luo, C. -B. ;
Chang, F. -C. ;
Teng, M. M. -H. ;
Guo, W. -Y. ;
Chang, C. -Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) :1951-1955