Evaluation of the Efficacy of Flow Cytometry in Detecting Bacterial Contamination in Platelets

被引:0
作者
Ziari, Maryam Habibi [1 ]
Razjou, Farhad [2 ]
Vaeli, Shahram [3 ]
Poshtiri, Fatemeh Abedi [4 ]
Dabirmoghadam, Abolfazi [5 ]
机构
[1] High Inst Res & Educ Transfus Med, Dept Hematol, Tehran, Iran
[2] Blood Transfus Org, Dept Pathol, Tehran, Iran
[3] Blood Transfus Org, Dept Lab Sci, Tehran, Iran
[4] Islamic Azad Univ, Dept Med Lab Sci, Babol Branch, Babol Sar, Iran
[5] Blood Transfus Org, Dept Microbiol, Tehran, Iran
关键词
Flow cytometry; bacterial contamination; platelet units; SYSTEMS;
D O I
10.9734/JPRI/2019/v27i330168
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Bacterial contamination of platelet products is a major risk of infections in blood transfusion. Due to their storage conditions at room temperatures (22 to 24 degrees C), cases of septicemia and even death caused by platelet injection have been reported. Therefore, use of appropriate diagnostic methods can improve the health of this product. In this study, flow cytometry was used to detect contaminated platelet units. Methods: This study was a diagnostic interventional type. 15 units of platelet concentrate was prepared at a minimum interval time after production. Staphylococcus epidermidis and Escherichia coli (E. coli) bacteria were each added to 6 platelet bags, with a concentration of 10 CFU / ml, while 3 bags were used as negative control. Platelets were stored in a shaking incubator at 22 - 24 degrees C, for 0, 6, 24 and 48 hour-intervals after inoculation. Samples were then taken at 1 ml volume and evaluated by flow cytometry. Results: The sensitivity of the flow cytometry method to detect contaminated platelet units in infections with both Staphylococcus epidermidis and E. coli, in a 1 ml volume in all samples at 0, 6, 22 and 24 hours after inoculation, was 100%, and the number of bacteria increased in 24 hours of incubation, except for E. coli that decreased after 24 hours. Conclusion: This study shows that flow cytometry can be a useful method for detecting bacterial contamination in platelets, and can detect low concentrations (10 CFU / ml) of bacteria in small volumes of sample (ml) in a short time.
引用
收藏
页数:9
相关论文
共 18 条
[1]   Limiting and detecting bacterial contamination of apheresis platelets: inlet-line diversion and increased culture volume improve component safety [J].
Eder, Anne F. ;
Kennedy, Jean M. ;
Dy, Beth A. ;
Notari, Edward P. ;
Skeate, Robert ;
Bachowski, Gary ;
Mair, David C. ;
Webb, Jonathan S. ;
Wagner, Stephen J. ;
Dodd, Roger Y. ;
Benjamin, Richard J. .
TRANSFUSION, 2009, 49 (08) :1554-1563
[2]   Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection with aerobic culture [J].
Ezuki, Shoji ;
Kawabata, Kinuyo ;
Kanno, Takahiro ;
Ohto, Hitoshi .
TRANSFUSION, 2007, 47 (11) :2044-2049
[3]   Routine use of a rapid test to detect bacteria at the time of issue for nonleukoreduced, whole bloodderived platelets [J].
Harm, Sarah K. ;
Delaney, Meghan ;
Charapata, Michael ;
AuBuchon, James P. ;
Triulzi, Darrell J. ;
Yazer, Mark H. .
TRANSFUSION, 2013, 53 (04) :843-850
[4]   Current applications of multiparameter flow cytometry in plasma cell disorders [J].
Jelinek, T. ;
Bezdekova, R. ;
Zatopkova, M. ;
Burgos, L. ;
Simicek, M. ;
Sevcikova, T. ;
Paiva, B. ;
Hajek, R. .
BLOOD CANCER JOURNAL, 2017, 7 :e617-e617
[5]   A Prospective Study to Determine the Frequency of Bacterial Contamination of Platelets [J].
Kulkarni, Nagarekha .
INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2014, 30 (04) :319-320
[6]  
Lee HR, 2012, ANN CLIN LAB SCI, V42, P174
[7]   Bacterial contamination of platelets for transfusion: strategies for prevention [J].
Levy, Jerrold H. ;
Neal, Matthew D. ;
Herman, Jay H. .
CRITICAL CARE, 2018, 22
[8]   Bacterial contamination in platelet concentrates [J].
Pietersz, R. N. I. ;
Reesink, H. W. ;
Panzer, S. ;
Oknaian, S. ;
Kuperman, S. ;
Gabriel, C. ;
Rapaille, A. ;
Lambermont, M. ;
Deneys, V. ;
Sondag, D. ;
Ramirez-Arcos, S. ;
Goldman, M. ;
Delage, G. ;
Bernier, F. ;
Germain, M. ;
Vuk, T. ;
Georgsen, J. ;
Morel, P. ;
Naegelen, C. ;
Bardiaux, L. ;
Cazenave, J. -P. ;
Dreier, J. ;
Vollmer, T. ;
Knabbe, C. ;
Seifried, E. ;
Hourfar, K. ;
Lin, C. K. ;
Spreafico, M. ;
Raffaele, L. ;
Berzuini, A. ;
Prati, D. ;
Satake, M. ;
de Korte, D. ;
van der Meer, P. F. ;
Kerkhoffs, J. L. ;
Blanco, L. ;
Kjeldsen-Kragh, J. ;
Svard-Nilsson, A. -M. ;
McDonald, C. P. ;
Symonds, I. ;
Moule, R. ;
Brailsford, S. ;
Yomtovian, R. ;
Jacobs, M. R. .
VOX SANGUINIS, 2014, 106 (03) :256-283
[9]   Microbiological Screening of Platelet Concentrates in Europe [J].
Prax, Marcel ;
Bekeredjian-Ding, Isabelle ;
Krut, Oleg .
TRANSFUSION MEDICINE AND HEMOTHERAPY, 2019, 46 (02) :76-86
[10]   Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates [J].
Riedel, Stefan ;
Siwek, Gregory ;
Beekmann, Susan E. ;
Richter, Sandra S. ;
Raife, Thomas ;
Doern, Gary V. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) :2262-2264