Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: A numeric analysis

被引:0
作者
Wang, TM
Leu, LJ
Wang, JS
Lin, LD
机构
[1] Natl Taiwan Univ, Grad Inst Dent, Coll Med, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Sch Dent, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Dept Civil Engn, Taipei 100, Taiwan
关键词
dental implants; finite element analysis; prosthesis material;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A 3-dimensional finite element model consisting of a bore block and 2 simulated premolar crowns supported by 2 adjacent cylindric implants without immediately surrounding cortical bone was generated and used to investigate the effects of prosthesis materials and prosthesis splinting on the peri-implant bone stress under static loads. Materials and Methods: the peri-implant maximum equivalent bone stress (von Mises [VM] stress) was evaluated when a vertical or a horizontal load of 1 N was applied to the center of a single resin, gold alloy, or porcelain crown, nonsplinted or splinted to the adjacent crown. Results: The numeric results indicated that: (1) in a single crown, no significant difference could be found in the maximum VM stress between different materials for both vertical and horizontal loading; (2) splinting the crowns reduced the maximum VM stress induced by the horizontal load, and the maximum VM stress increased about 14% for the horizontal loading when the restorative material was changed from gold alloy or porcelain to resin. Discussion: Under the condition of this study's analysis, prosthesis materials of a single crown have insignificant effects on the peri-implant bone stress. Splinting the crowns reduced the peri-implant bone stress under horizontal load, and gold alloy and porcelain each demonstrated less peri-implant bone stress than resin in the splinted crown situation under static horizontal load. Conclusion: Splinting the crowns of adjacent implants with relatively stiff restorative materials is recommended for implants surrounded by poor-quality bone.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 27 条
[1]  
Babbush C A, 1987, Int J Oral Maxillofac Implants, V2, P203
[2]  
Benzing U R, 1995, Int J Oral Maxillofac Implants, V10, P188
[3]   OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[4]  
Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
[5]  
Davis D M, 1988, Int J Oral Maxillofac Implants, V3, P275
[6]  
FRIBERG B, 1991, International Journal of Oral and Maxillofacial Implants, V6, P142
[7]   BONE MASS AND THE MECHANOSTAT - A PROPOSAL [J].
FROST, HM .
ANATOMICAL RECORD, 1987, 219 (01) :1-9
[8]  
GRACIS S E, 1991, International Journal of Prosthodontics, V4, P282
[9]  
Holmes D C, 1994, Int J Prosthodont, V7, P239
[10]   Loss of osseointegration caused by occlusal load of oral implants - A clinical and radiographic study in monkeys [J].
Isidor, F .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (02) :143-152