Predictive Values of Thermal and Electrical Dental Pulp Tests: A Clinical Study

被引:40
作者
Villa-Chavez, Carlos E. [1 ]
Patino-Marin, Nuria [1 ]
Loyola-Rodriguez, Juan P. [2 ]
Zavala-Alonso, Norma V. [3 ]
Martinez-Castanon, Gabriel A. [3 ]
Medina-Solis, Carlo E. [4 ]
机构
[1] San Luis Potosi Univ, Masters Degree Dent Sci Specializat Adv Gen Dent, Clin Invest Lab, San Luis Potosi, Mexico
[2] San Luis Potosi Univ, Masters Degree Dent Sci Specializat Adv Gen Dent, Lab Mol Biol & Oral Microbiol, San Luis Potosi, Mexico
[3] San Luis Potosi Univ, Masters Degree Dent Sci Specializat Adv Gen Dent, Lab Nanobiomat, San Luis Potosi, Mexico
[4] Autonomous Univ State Hidalgo, Inst Hlth Sci, Area Dent, Pachuca, Hidalgo, Mexico
关键词
Electrical dental pulp test; predictive values; thermal dental pulp tests; RELIABILITY; DIAGNOSIS; VITALITY; EFFICACY; SPRAY; PROBE; COLD;
D O I
10.1016/j.joen.2013.04.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: For a diagnostic test to be useful, it is necessary to determine the probability that the test will provide the correct diagnoSis. Therefore, it is necessary to calculate the predictive value of diagnostics. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values, accuracy, and reproducibility of thermal and electrical tests of pulp sensitivity. Methods: The thermal tests studied were the 1, 1, 1, 2-tetrafluoroethane (cold) and hot gutta-percha (hot) tests. For the electrical test, the Analytic Technology Pulp Tester (Analytic Technology, Redmond, WA) was used. A total of 110 teeth were tested: 60 teeth with vital pulp and 50 teeth with necrotic pulps (disease prevalence of 45%). The ideal standard was established by direct pulp inspection. Results: The sensitivities of the diagnostic tests were 0.88 for the cold test, 0.86 for the heat test, and 0.76 for the electrical test, and the specificity was 1.0 for all 3 tests. The negative predictive value was 0.90 for the cold test, 0.89 for the heat test, and 0.83 for the electrical test, and the positive predictive value was 1.0 for all 3 tests. The highest accuracy (0.94) and reproducibility (0.88) were observed for the cold test. Conclusions: The cold test was the most accurate method for diagnostic testing.
引用
收藏
页码:965 / 969
页数:5
相关论文
共 25 条
[1]   DIAGNOSTIC-TESTS-2 - PREDICTIVE VALUES .4. [J].
ALTMAN, DG ;
BLAND, JM .
BRITISH MEDICAL JOURNAL, 1994, 309 (6947) :102-102
[2]   Comparison of Heat-testing Methodology [J].
Bierma, Mark M. ;
McClanahan, Scott ;
Baisden, Michael K. ;
Bowles, Walter R. .
JOURNAL OF ENDODONTICS, 2012, 38 (08) :1106-1109
[3]   DENTAL SENSORY RECEPTORS [J].
BYERS, MR .
INTERNATIONAL REVIEW OF NEUROBIOLOGY, 1984, 25 :39-94
[4]   Evaluation of Accuracy, Reliability, and Repeatability of Five Dental Pulp Tests [J].
Chen, Eugene ;
Abbott, Paul V. .
JOURNAL OF ENDODONTICS, 2011, 37 (12) :1619-1623
[6]   Comparison of the Efficacy of a Custom-made Pulse Oximeter Probe with Digital Electric Pulp Tester, Cold Spray, and Rubber Cup for Assessing Pulp Vitality [J].
Dastmalchi, Nafiseh ;
Jafarzadeh, Hamid ;
Moradi, Saeed .
JOURNAL OF ENDODONTICS, 2012, 38 (09) :1182-1186
[7]   The Variability of Electric Pulp Response Threshold in Premolars: A Clinical Study [J].
Filippatos, Christos G. ;
Tsatsoulis, Ioannis N. ;
Floratos, Spyros ;
Kontakiotis, Evangelos G. .
JOURNAL OF ENDODONTICS, 2012, 38 (02) :144-147
[8]   ASSESSMENT OF RELIABILITY OF ELECTRICAL AND THERMAL PULP TESTING AGENTS [J].
FUSS, Z ;
TROWBRIDGE, H ;
BENDER, IB ;
RICKOFF, B ;
SORIN, S .
JOURNAL OF ENDODONTICS, 1986, 12 (07) :301-305
[9]   Evaluation of efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality [J].
Gopikrishna, Velayutham ;
Dnagupta, Kush ;
Kandaswamy, Deivanayagam .
JOURNAL OF ENDODONTICS, 2007, 33 (04) :411-414
[10]   THE PREDICTIVE VALUE OF ENDODONTIC DIAGNOSTIC-TESTS [J].
HYMAN, JJ ;
COHEN, ME .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1984, 58 (03) :343-346