Influence of the conductor's arrangement and current on the AC loss characteristics of a fault current limiting coil

被引:2
作者
Li, Z. Y. [1 ]
Ma, Y. H. [1 ]
Ryu, K. [1 ]
Choi, S. [2 ]
Park, K. B. [3 ]
Oh, I. S. [3 ]
机构
[1] Chonnam Natl Univ, Dept Elect Engn, Kwangju 500757, South Korea
[2] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050003, Japan
[3] LS Ind Syst, Technol R&D Ctr, Chonju 361720, South Korea
来源
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS | 2008年 / 468卷 / 15-20期
关键词
AC loss; conductor arrangement; current direction; fault current limiting coil;
D O I
10.1016/j.physc.2008.05.127
中图分类号
O59 [应用物理学];
学科分类号
摘要
Researches and developments on a superconducting fault current limiting (SFCL) system have been done for several decades. The SFCL system. which is using a high temperature superconducting (HTS) conductor such as Bi-2212 bulk and YBCO film, has recently become technically available. In this work, we are developing a 22.9 kV/25 MVA SFCL system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric held during fault of the power network, becomes a candidate for our resistive SFCL system. AC loss of the HTS conductor has a strong influence on the economic viability of the SFCL system, which offers an attractive means to limit short circuit current in the power network. As an earlier stage of our 22.9 kV/25 MVA SFCL system development, we prepared several samples of the fault current limiting elements in a coil shape to reduce AC loss of the SFCL system. The effect of conductor's arrangement and current direction on AC loss characteristics of the fault current limiting coils has been investigated experimentally. The test result shows that the measured AC loss depends significantly on the conductor's arrangement and also on the current direction even in the same arrangement. The AC loss of a face-to-face coil in bifilar mode, which is even smaller than the self-field loss of the conductor, is smallest among our fabricated coil samples. Moreover, the measured loss in the face-to-face coil in bifilar mode is invariable regardless of thickness in an insulator which is placed between conductors. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2063 / 2066
页数:4
相关论文
共 7 条
[1]   Self-field ac losses in mono- and multi-filamentary Bi-2223/Ag tapes at power frequencies [J].
Awan, SA ;
Sali, S ;
Friend, CM ;
Beales, TP .
CRYOGENICS, 1997, 37 (10) :633-635
[2]   CURL 10: Development and field-test of a 10 kV/10 MVA resistive current limiter based on bulk MCP-BSCCO 2212 [J].
Bock, J ;
Breuer, F ;
Walter, H ;
Elschner, S ;
Kleimaier, M ;
Kreutz, R ;
Noe, M .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :1955-1960
[3]   AC transport current loss of horizontally attached Bi-2223/Ag tapes [J].
Choi, S ;
Nah, W ;
Kim, JH ;
Joo, J ;
Jo, YH ;
Ryu, KW .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) :1894-1897
[4]   6.6 kV resistive superconducting fault current limiter based on YBCO films [J].
Hyun, OB ;
Kim, HR ;
Sim, J ;
Jung, YH ;
Park, KB ;
Kang, JS ;
Lee, BW ;
Oh, IS .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :2027-2030
[5]   Bi-2223 and Bi-2212 tubes for Small fault current limiters [J].
Janowski, T ;
Stryczewska, HD ;
Kozak, S ;
Kondratowicz-Kucewicz, B ;
Wojtasiewicz, G ;
Kozak, J ;
Surdacki, P ;
Malinowski, H .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) :851-854
[6]   Effect of the neighboring tape's AC currents on transport current loss of a Bi-2223 tape [J].
Ryu, K ;
Park, KB ;
Cha, G .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2220-2223
[7]  
RYU K, 2005, J KOREA I ELECT ELEC, V18, P370