A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

被引:13
作者
MacDonald, Jason S. [1 ]
Vrettos, Evangelos [2 ]
Callaway, Duncan S. [3 ]
机构
[1] Lawrence Berkeley Natl Lab, Energy Storage & Distributed Resources Div, Berkeley, CA 94720 USA
[2] Swissgrid, Res & Digitalisat Team, CH-5001 Aarau, Switzerland
[3] Univ Calif Berkeley, Energy & Resources Grp, Berkeley, CA 94720 USA
关键词
Energy management; Measurement; Batteries; Energy efficiency; Energy consumption; State of charge; Energy storage; Renewable energy sources; Ventilation; Battery analogy; demand response (DR); energy cost; round-trip efficiency (RTE); ROUND-TRIP EFFICIENCY; FREQUENCY REGULATION; PERFORMANCE;
D O I
10.1109/JPROC.2020.3006804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.
引用
收藏
页码:1623 / 1639
页数:17
相关论文
共 33 条
[21]  
MacDonald J., 2012, P GRID INT IRV TX US
[22]   Operational Impacts of Wind Generation on California Power Systems [J].
Makarov, Yuri V. ;
Loutan, Clyde ;
Ma, Jian ;
de Mello, Phillip .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (02) :1039-1050
[23]   Variability in automated responses of commercial buildings and industrial facilities to dynamic electricity prices [J].
Mathieu, Johanna L. ;
Callaway, Duncan S. ;
Kiliccote, Sila .
ENERGY AND BUILDINGS, 2011, 43 (12) :3322-3330
[24]   Quantifying energy losses in hot water reheat systems [J].
Raftery, Paul ;
Geronazzo, Angela ;
Cheng, Hwakong ;
Paliaga, Gwelen .
ENERGY AND BUILDINGS, 2018, 179 :183-199
[25]   On the Round-Trip Efficiency of an HVAC-Based Virtual Battery [J].
Raman, Naren Srivaths ;
Barooah, Prabir .
IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) :403-410
[26]  
Raman NS, 2018, P 5 INT HIGH PERF BU
[27]  
Strbac G, 2017, IEEE POWER ENERGY M, V15, P32, DOI 10.1109/MPE.2017.2708858
[28]  
The US Federal Energy Regulatory Commission, 2011, 745 US FED EN REG CO
[29]   Experimental Demonstration of Frequency Regulation by Commercial Buildings-Part II: Results and Performance Evaluation [J].
Vrettos, Evangelos ;
Kara, Emre C. ;
MacDonald, Jason ;
Andersson, Goran ;
Callaway, Duncan S. .
IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) :3224-3234
[30]   Experimental Demonstration of Frequency Regulation by Commercial Buildings Part I: Modeling and Hierarchical Control Design [J].
Vrettos, Evangelos ;
Kara, Emre C. ;
MacDonald, Jason ;
Andersson, Goran ;
Callaway, Duncan S. .
IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) :3213-3223