A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

被引:13
作者
MacDonald, Jason S. [1 ]
Vrettos, Evangelos [2 ]
Callaway, Duncan S. [3 ]
机构
[1] Lawrence Berkeley Natl Lab, Energy Storage & Distributed Resources Div, Berkeley, CA 94720 USA
[2] Swissgrid, Res & Digitalisat Team, CH-5001 Aarau, Switzerland
[3] Univ Calif Berkeley, Energy & Resources Grp, Berkeley, CA 94720 USA
关键词
Energy management; Measurement; Batteries; Energy efficiency; Energy consumption; State of charge; Energy storage; Renewable energy sources; Ventilation; Battery analogy; demand response (DR); energy cost; round-trip efficiency (RTE); ROUND-TRIP EFFICIENCY; FREQUENCY REGULATION; PERFORMANCE;
D O I
10.1109/JPROC.2020.3006804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.
引用
收藏
页码:1623 / 1639
页数:17
相关论文
共 33 条
[1]  
[Anonymous], 2019, SHENZHEN STAT YB
[2]   Round-trip efficiency of fast demand response in a large commercial air conditioner [J].
Beil, I. ;
Hiskens, I. A. ;
Backhaus, S. .
ENERGY AND BUILDINGS, 2015, 97 :47-55
[3]   Frequency Regulation From Commercial Building HVAC Demand Response [J].
Beil, Ian ;
Hiskens, Ian ;
Backhaus, Scott .
PROCEEDINGS OF THE IEEE, 2016, 104 (04) :745-757
[4]   Opportunity Cost Quantification for Ancillary Services Provided by Heating, Ventilating, and Air-Conditioning Systems [J].
Blum, David H. ;
Zakula, Tea ;
Norford, Leslie K. .
IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (03) :1264-1273
[5]   Laboratory-based assessment of HVAC equipment for power grid frequency regulation: Methods, regulation performance, economics, indoor comfort and energy efficiency [J].
Cai, Jie ;
Braun, James E. .
ENERGY AND BUILDINGS, 2019, 185 :148-161
[6]  
California Independent System Operator Corporation, 2019, 5 REPL TAR SECT 11 C
[7]  
California Public Utilities Commission, 2013, ORD I RUL ENH RUL DE
[8]   Achieving Controllability of Electric Loads [J].
Callaway, Duncan S. ;
Hiskens, Ian A. .
PROCEEDINGS OF THE IEEE, 2011, 99 (01) :184-199
[9]  
Eyer J., 2010, ALBUQUERQUE
[10]  
Foster B., 2019, TECH REP